Active High Voltage Differential Probe

$2,021.19
Buy active high voltage differential probe online at an economical price, with bandwidth from 70MHz to 200MHz, and common mode voltage from 700V to 7000V. This active high voltage differential probe is used for measuring high-voltage signals of the oscilloscope with precision and safety.
SKU: ATO-HVDP-6000
*
Free Shipping
Delivery date: 6-12 days

Active high voltage differential probe is used to measure high voltage signals with precision while maintaining safety. It features active electronics that amplify the signal, allowing it to measure high voltage differences between two points without requiring a direct ground reference.

Specification

ModelATO-DP6070AATO-DP6150ATO-DP6150AATO-DP6150BATO-DP6280ATO-DP6700ATO-DP6700A
Bandwidth (-3dB)100MHz70MHz100MHz200MHz100MHz70MHz100MHz
Rise Time≤3.5ns≤5ns≤3.5ns≤1.75ns≤3.5ns≤5ns≤3.5ns
Accuracy±2%
Range Selection (Attenuation Ratio)10X/100X50X/500X100X/1000X
Maximum Differential Measurement Voltage (DC + Peak AC)10X: ±70V50X: ±150V100X: ±280V100X: ±700V
100X: ±700V500X: ±1500V1000X: ±2800V1000X: ±7000V
Common Mode Voltage (DC + Peak AC)±700V±1500V±2800V±7000V
Maximum Input Voltage to Ground (Vrms)450V CATⅡ600V CATⅢ1000V CATⅢ
600V CATⅠ1000V CATⅡ2300V CATⅠ
Input ImpedanceSingle-Ended to Ground2.5MΩ5MΩ20MΩ
Two Input Terminals5MΩ10MΩ40MΩ
Input CapacitanceSingle-Ended to Ground<4pF<5pF
Two Input Terminals<2pF<2.5pF
CMRRDC>80dB
100kHz>60dB
1MHz>50dB
Noise (Vrms)10X: <20mV50X: <50mV100X: <100mV100X: <200mV
100X: <120mV500X: <300mV1000X: <600mV1000X: <1.2V
Overload Indication Voltage Threshold10X: ≥70V50X: ≥150V100X: ≥280V100X: ≥700V
100X: ≥700V500X: ≥1500V1000X: ≥2800V1000X: ≥7000V
Delay TimeProbe Host9ns
BNC Cable
(1m)
5ns
Bandwidth Limit (5MHz)≥-3dB@5MHz
Overload Indicator (Red Light)Yes
Overload Alarm SoundYes (Optionally Close)
Auto Save FunctionYes
Bias Adjustable FunctionYes (Adjust in Test Mode)
Terminal Load Requirement≥100kΩ
Power SupplyUSB 5V/1A Adapter
Safety ComplianceEN61010-1: 2010
EMC ComplianceEN61326-1:2013 EN61000-3-2:2006+A1:2009+A2:2009 EN61000-3-3:2013


Details

Active high voltage differential probe details

Maximum Differential Mode Voltage vs. Frequency Curve

High voltage differential probe differential mode voltage vs frequency diagram

Tips: What is an active high voltage differential probe?

An active high voltage differential probe is a specialized instrument used to measure high-voltage signals with high accuracy and safety. It features two input channels that measure the voltage difference between them, rather than referencing a single point to ground. This allows it to accurately capture signals in environments with high common-mode voltages. The probe has built-in amplification and isolation circuitry to handle high voltages safely, protecting both the user and the measurement equipment. It typically connects to an oscilloscope or similar device for signal analysis. The active design enhances accuracy by minimizing noise and distortion, making it crucial for testing and troubleshooting high-voltage systems in power electronics, telecommunications, and other high-power applications.

Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Active high voltage differential probe is used to measure high voltage signals with precision while maintaining safety. It features active electronics that amplify the signal, allowing it to measure high voltage differences between two points without requiring a direct ground reference.

Specification

ModelATO-DP6070AATO-DP6150ATO-DP6150AATO-DP6150BATO-DP6280ATO-DP6700ATO-DP6700A
Bandwidth (-3dB)100MHz70MHz100MHz200MHz100MHz70MHz100MHz
Rise Time≤3.5ns≤5ns≤3.5ns≤1.75ns≤3.5ns≤5ns≤3.5ns
Accuracy±2%
Range Selection (Attenuation Ratio)10X/100X50X/500X100X/1000X
Maximum Differential Measurement Voltage (DC + Peak AC)10X: ±70V50X: ±150V100X: ±280V100X: ±700V
100X: ±700V500X: ±1500V1000X: ±2800V1000X: ±7000V
Common Mode Voltage (DC + Peak AC)±700V±1500V±2800V±7000V
Maximum Input Voltage to Ground (Vrms)450V CATⅡ600V CATⅢ1000V CATⅢ
600V CATⅠ1000V CATⅡ2300V CATⅠ
Input ImpedanceSingle-Ended to Ground2.5MΩ5MΩ20MΩ
Two Input Terminals5MΩ10MΩ40MΩ
Input CapacitanceSingle-Ended to Ground<4pF<5pF
Two Input Terminals<2pF<2.5pF
CMRRDC>80dB
100kHz>60dB
1MHz>50dB
Noise (Vrms)10X: <20mV50X: <50mV100X: <100mV100X: <200mV
100X: <120mV500X: <300mV1000X: <600mV1000X: <1.2V
Overload Indication Voltage Threshold10X: ≥70V50X: ≥150V100X: ≥280V100X: ≥700V
100X: ≥700V500X: ≥1500V1000X: ≥2800V1000X: ≥7000V
Delay TimeProbe Host9ns
BNC Cable
(1m)
5ns
Bandwidth Limit (5MHz)≥-3dB@5MHz
Overload Indicator (Red Light)Yes
Overload Alarm SoundYes (Optionally Close)
Auto Save FunctionYes
Bias Adjustable FunctionYes (Adjust in Test Mode)
Terminal Load Requirement≥100kΩ
Power SupplyUSB 5V/1A Adapter
Safety ComplianceEN61010-1: 2010
EMC ComplianceEN61326-1:2013 EN61000-3-2:2006+A1:2009+A2:2009 EN61000-3-3:2013


Details

Active high voltage differential probe details

Maximum Differential Mode Voltage vs. Frequency Curve

High voltage differential probe differential mode voltage vs frequency diagram

Tips: What is an active high voltage differential probe?

An active high voltage differential probe is a specialized instrument used to measure high-voltage signals with high accuracy and safety. It features two input channels that measure the voltage difference between them, rather than referencing a single point to ground. This allows it to accurately capture signals in environments with high common-mode voltages. The probe has built-in amplification and isolation circuitry to handle high voltages safely, protecting both the user and the measurement equipment. It typically connects to an oscilloscope or similar device for signal analysis. The active design enhances accuracy by minimizing noise and distortion, making it crucial for testing and troubleshooting high-voltage systems in power electronics, telecommunications, and other high-power applications.

Only registered users can write reviews