Handheld Voltage Current Thermocouple Calibrator, Output Signal Source

$146.03
This handheld calibration tool is a voltage, current and thermocouple signal source/generator, able to output and measure 0-30V, 0-24mV, and 0-100mV voltage signal, 0-24mA and 4-20mA current signal and K, E, J, T, R, B, S, N type thermocouple, easy to use and high accuracy, helpful for testing and calibration in the industry field.
SKU: ATO-SIGNAL-C703
*
Free Shipping
Delivery date: 6-12 days

This calibration tool outputs and measures voltage/current/thermocouple signal source, and features simple operation, long standby time, high accuracy and programmable output with LCD screen and silicone keyboard. It’s widely used for calibration or debugging in labs, PLC industry site, process instruments, electric valves and other areas.

Specification

Basic Information
ModelATO-C703
Main FunctionsVoltage signal: 0-30V, 0-24mV, 0-100mV output and measurement
Current signal: 0-24mA, 4-20mA output and measurement
Thermocouple: K, E, J, T, R, B, S output and measurement
Operating Temperature-10~55℃
Operating Humidity20%~80%RH, non-condensing
Storage Tempeature-20~70℃
Size115*71*30mm
Weight300g
Power Supply4 AAA batteries or 5V/1A power adapter
Power Dissipation200mA, 4 hours under full load when powered by 4 AAA batteries (nominal capacity of a single battery is 1100mAh), and 17 hours in standby mode.
Battery Life7~10 hours
Over Current Protection (OCP)30V
Technical Parameters (Signal Output and Measurement Functions)
ItemSignal TypeRangeAccuracyResolutionRemarks
DC Voltage20mV0.00-24.00mV±0.1%0.01mV/
100mV0.00-100.00mV±0.1%0.01mV
VOutput 0.00-15.00V±0.1%0.01VOutput: 30mA maximum current
Measure: 1.2MΩ input impedance
Measure 0.00-30.00V±0.1%0.01V
DC CurrentmA0.00-24.00mA±0.1%0.01AOutput: 750Ω maximum load
Measure: 100Ω input impedance
4-20mA4/8/12/16/20mA±0.1%0.01mA
Passive CurrentmA0.00-24.00mA±0.1%0.01mAOutput: 16-30V external power
Power Distribution Output24VLOOP24V/16V±10%0.1VDrive current 24mA
ThermocoupleK-270~1372℃±1%1℃Output: range only from 0℃
E-270~1000℃±1%1℃
J-210~1200℃±1%1℃
T-270~400℃±1%1℃
R-50~1768℃±1%1℃
B0~1820℃±1%1℃
S-50~1768℃±1%1℃
N-270~1300℃±1%1℃

Selection table
There are also available with other calibrators/signal source generators with different functions. Please check the table below for more details. Buy a suitable one for routine maintenance of your devices.

FunctionsSignal TypeProduct Model (Optional)Accuracy
C703C703S
DC Voltage


20mVYY±0.2%
100mVYY
Output 0~15VYY
Measure 0~30VYY
DC CurrentmAYY
4~20mAYY
Passive CurrentmAYY
Power Distribution Output24VLOOPYY±10%
ThermocoupleK/E/J/T/R/B/S/NYY±1%
Thermal ResistancePT100N/AY±0.2%
ResistanceΩN/AY±0.2%
Range ConversionmAYY/
Programmable Output/YY/

Note:
* For the specific parameters of the above functions, please click here.

Details

Handheld Voltage Current Thermocouple Calibrator Details

Tips: Troubleshooting & maintenance of C703 handheld signal source calibrator

1. Troubleshooting

  • Nothing displays on the LCD screen after turning on the signal source.
    a. Check if the battery is OK.
    b. Check if the power adapter outputs the current of 1000mA.
  • The measurement result cannot display.
    Make sure that the signal source calibrator is on the status of MEASURE.
  • The output or measure value is abnormal.
    a. Check if the signal wires are connected correctly.
    b. Make sure that the right signal type is chosen.

2. Maintenance

  • This handheld signal source calibrator is powered by 3.7V rechargeable lithium battery. For a long time use, please power it by power adapter so as to extend the lifespan of battery.
  • If you use a phone charger to charge the instrument, please confirm that the phone charger output current is 1000mA.
  • The instrument is not waterproof. Please keep it away from too humid environment.

How to Differentiate Between Active & Passive Signals
The handheld voltage current thermocouple calibrator is a portable measuring device mainly used to calibrate thermocouple sensors. A thermocouple sensor is a common temperature measurement device that measures temperature based on the temperature difference at the point of contact between two different metal materials. The handheld voltage and current thermocouple calibrator provides accurate voltage and current outputs for simulating different temperature environments to calibrate thermocouple sensors. The following will show you directly through the basic experiment of distinguishing active signals and passive signals, using a handheld precision multifunction calibrator, a multimeter and a DC power supply to build a signal acquisition loop.

Product reviews
Great signal source
5
Manu
Avatar
10/24/2018 8:24 PM
This handheld signal generator is right for me. It is small and easy to carry. Just put it in my pocket when I go to the industrial site. Besides, it is not too complex and I can operate this very well soon. Works as advertised.
Was this review helpful? Yes No (1/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

This calibration tool outputs and measures voltage/current/thermocouple signal source, and features simple operation, long standby time, high accuracy and programmable output with LCD screen and silicone keyboard. It’s widely used for calibration or debugging in labs, PLC industry site, process instruments, electric valves and other areas.

Specification

Basic Information
ModelATO-C703
Main FunctionsVoltage signal: 0-30V, 0-24mV, 0-100mV output and measurement
Current signal: 0-24mA, 4-20mA output and measurement
Thermocouple: K, E, J, T, R, B, S output and measurement
Operating Temperature-10~55℃
Operating Humidity20%~80%RH, non-condensing
Storage Tempeature-20~70℃
Size115*71*30mm
Weight300g
Power Supply4 AAA batteries or 5V/1A power adapter
Power Dissipation200mA, 4 hours under full load when powered by 4 AAA batteries (nominal capacity of a single battery is 1100mAh), and 17 hours in standby mode.
Battery Life7~10 hours
Over Current Protection (OCP)30V
Technical Parameters (Signal Output and Measurement Functions)
ItemSignal TypeRangeAccuracyResolutionRemarks
DC Voltage20mV0.00-24.00mV±0.1%0.01mV/
100mV0.00-100.00mV±0.1%0.01mV
VOutput 0.00-15.00V±0.1%0.01VOutput: 30mA maximum current
Measure: 1.2MΩ input impedance
Measure 0.00-30.00V±0.1%0.01V
DC CurrentmA0.00-24.00mA±0.1%0.01AOutput: 750Ω maximum load
Measure: 100Ω input impedance
4-20mA4/8/12/16/20mA±0.1%0.01mA
Passive CurrentmA0.00-24.00mA±0.1%0.01mAOutput: 16-30V external power
Power Distribution Output24VLOOP24V/16V±10%0.1VDrive current 24mA
ThermocoupleK-270~1372℃±1%1℃Output: range only from 0℃
E-270~1000℃±1%1℃
J-210~1200℃±1%1℃
T-270~400℃±1%1℃
R-50~1768℃±1%1℃
B0~1820℃±1%1℃
S-50~1768℃±1%1℃
N-270~1300℃±1%1℃

Selection table
There are also available with other calibrators/signal source generators with different functions. Please check the table below for more details. Buy a suitable one for routine maintenance of your devices.

FunctionsSignal TypeProduct Model (Optional)Accuracy
C703C703S
DC Voltage


20mVYY±0.2%
100mVYY
Output 0~15VYY
Measure 0~30VYY
DC CurrentmAYY
4~20mAYY
Passive CurrentmAYY
Power Distribution Output24VLOOPYY±10%
ThermocoupleK/E/J/T/R/B/S/NYY±1%
Thermal ResistancePT100N/AY±0.2%
ResistanceΩN/AY±0.2%
Range ConversionmAYY/
Programmable Output/YY/

Note:
* For the specific parameters of the above functions, please click here.

Details

Handheld Voltage Current Thermocouple Calibrator Details

Tips: Troubleshooting & maintenance of C703 handheld signal source calibrator

1. Troubleshooting

  • Nothing displays on the LCD screen after turning on the signal source.
    a. Check if the battery is OK.
    b. Check if the power adapter outputs the current of 1000mA.
  • The measurement result cannot display.
    Make sure that the signal source calibrator is on the status of MEASURE.
  • The output or measure value is abnormal.
    a. Check if the signal wires are connected correctly.
    b. Make sure that the right signal type is chosen.

2. Maintenance

  • This handheld signal source calibrator is powered by 3.7V rechargeable lithium battery. For a long time use, please power it by power adapter so as to extend the lifespan of battery.
  • If you use a phone charger to charge the instrument, please confirm that the phone charger output current is 1000mA.
  • The instrument is not waterproof. Please keep it away from too humid environment.
Product reviews
Great signal source
5
Manu
Avatar
10/24/2018 8:24 PM
This handheld signal generator is right for me. It is small and easy to carry. Just put it in my pocket when I go to the industrial site. Besides, it is not too complex and I can operate this very well soon. Works as advertised.
Was this review helpful? Yes No (1/0)
Only registered users can write reviews
Customers who bought this item also bought

Handheld Precision Multifunction Calibrator, Output Signal Source

ATO-SIGNAL-LR-C512
$412.22
This handheld multifunction calibrator is a high precision signal source/generator, designed to output variety of signals including DC voltage, DC current, resistance, RTD, thermocouple, pulse frequency, and power distribution, ideal tool for calibrating and troubleshooting detectors.