Fire Smoke Detector, Wired, Smoke Alarms

$171.92
Fire smoke detector with hard wired equipped with explosion proof junction box, working voltage 9V~35V and work at -10℃~50℃. Wired fire alarm equipped with infrared photoelectric sensor detection distance reach to 80m, alarm via red led, network output. Smart fire alarm with alarm current 10mA, quiescent current 2uA, wide angle detection. SMT process design, strong stability, intelligent logic control.
SKU: ATO-SMOKE-B603
*
Free Shipping
Delivery date: 8-12 days

Smart fire alarm come with infrared photoelectric sensor, working voltage 9V~35V and alarm via red led. Work at -10℃~50℃, detection distance reach to 80m. Apply in house, office and so on.

Specification

ModelATO-B603
Operating VoltageDC 9V-35V, AC 220V (can be customized)
Quiescent Current≥2mA (DC 24V)
Alarm indicationRed led
Environment humidityMaximum 95%RH (no condensation)
Alarm OutputNO/NC contacts
Operating temperature-10°C~50°C   -40°C~80°C (can be customized)
Alarm current≥10mA (DC 24V)
SensorInfrared photoelectric sensor
Anti-RF interference10MHz~1GHz 20V/m
Sensitivity levellevel one
Coverage areaWhen the space height is 6m~12m, the protection area of a detector is larger than that of the general protection site.
The protection area is 60m when the space height is less than 6m, and the specific parameters should be based on GB50116~98 of the design specification for automatic fire alarm system
Detection angleWide angle
Detection distance80 (m)
Quiescent Current2 (uA)
Scope of applicationIndoor
Installation methodCeiling type
Communication methodWired

Feature

  1. Smart fire alarm with infrared photoelectric sensor/explosion-proof certification/network output
  2. The photoelectric smoke alarm detection range is wide, and when a small fire is detected, the alarm will be called immediately to extinguish the fire in the bud.
  3. This hard wired smoke detectors work on the principle of sensing smoke particles. Unique structural design and light.
  4. The electric signal processing technology has the functions of dustproof, insectproof, anti-interference of external light, etc. And the stability of the product is guaranteed from the design.
  5. Fire smoke detector has a good response to the visible smoke produced by slow smoldering or open burning.
  6. Fire detector with intelligent logic control, SMT process design, strong stability, intelligent logic control, filter out various false alarms, anti-white light interference design, metal shielding cover, anti-radio frequency dry (20v/m-1GHz).

Tips: What are the types of fire smoke alarm?

  1. The ionization smoke detector is mainly composed of two ionization chambers inside and outside. The outer ionization chamber (the detection chamber) has a hole that communicates with the outside world, and the smoke can enter the sensor through the hole; the inner ionization chamber (the compensation chamber) is sealed, and the smoke cannot enter. When a fire occurs, smoke particles enter the outer ionization chamber, which interferes with the normal operation of charged particles, changes the current and voltage, and destroys the balance between the inner and outer ionization chambers, and the detector will generate an induction and send out an alarm signal.
  2. There is a light-emitting element and a photosensitive element inside the photoelectric smoke detector. Usually, the light emitted by the light-emitting element is emitted to the photosensitive element through the lens, and the circuit remains normal. If there is smoke blocking it, the light reaching the photosensitive element will be obviously weakened, so the photosensitive element converts the change of light intensity into a change of current, and sends out an alarm signal through the amplifying circuit.
  3. The aspirating smoke detector has changed the traditional way of waiting for the smoke to drift to the detector to detect passively, but adopts a new concept, that is to say, to actively sample and detect the air. The aspirating pump inside the gas-type smoke detector sucks into the sampling pipe and sends it to the detector for analysis. If smoke particles are found, an alarm will be issued.
Product reviews
Very reliable
5
Stella
Avatar
3/22/2026 7:28 PM
We installed this smoke detector in our warehouse, and the infrared photoelectric sensor is impressively sensitive. Hardwired to the fire panel, it's been rock solid with zero false alarms.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Smart fire alarm come with infrared photoelectric sensor, working voltage 9V~35V and alarm via red led. Work at -10℃~50℃, detection distance reach to 80m. Apply in house, office and so on.

Specification

ModelATO-B603
Operating VoltageDC 9V-35V, AC 220V (can be customized)
Quiescent Current≥2mA (DC 24V)
Alarm indicationRed led
Environment humidityMaximum 95%RH (no condensation)
Alarm OutputNO/NC contacts
Operating temperature-10°C~50°C   -40°C~80°C (can be customized)
Alarm current≥10mA (DC 24V)
SensorInfrared photoelectric sensor
Anti-RF interference10MHz~1GHz 20V/m
Sensitivity levellevel one
Coverage areaWhen the space height is 6m~12m, the protection area of a detector is larger than that of the general protection site.
The protection area is 60m when the space height is less than 6m, and the specific parameters should be based on GB50116~98 of the design specification for automatic fire alarm system
Detection angleWide angle
Detection distance80 (m)
Quiescent Current2 (uA)
Scope of applicationIndoor
Installation methodCeiling type
Communication methodWired

Feature

  1. Smart fire alarm with infrared photoelectric sensor/explosion-proof certification/network output
  2. The photoelectric smoke alarm detection range is wide, and when a small fire is detected, the alarm will be called immediately to extinguish the fire in the bud.
  3. This hard wired smoke detectors work on the principle of sensing smoke particles. Unique structural design and light.
  4. The electric signal processing technology has the functions of dustproof, insectproof, anti-interference of external light, etc. And the stability of the product is guaranteed from the design.
  5. Fire smoke detector has a good response to the visible smoke produced by slow smoldering or open burning.
  6. Fire detector with intelligent logic control, SMT process design, strong stability, intelligent logic control, filter out various false alarms, anti-white light interference design, metal shielding cover, anti-radio frequency dry (20v/m-1GHz).

Tips: What are the types of fire smoke alarm?

  1. The ionization smoke detector is mainly composed of two ionization chambers inside and outside. The outer ionization chamber (the detection chamber) has a hole that communicates with the outside world, and the smoke can enter the sensor through the hole; the inner ionization chamber (the compensation chamber) is sealed, and the smoke cannot enter. When a fire occurs, smoke particles enter the outer ionization chamber, which interferes with the normal operation of charged particles, changes the current and voltage, and destroys the balance between the inner and outer ionization chambers, and the detector will generate an induction and send out an alarm signal.
  2. There is a light-emitting element and a photosensitive element inside the photoelectric smoke detector. Usually, the light emitted by the light-emitting element is emitted to the photosensitive element through the lens, and the circuit remains normal. If there is smoke blocking it, the light reaching the photosensitive element will be obviously weakened, so the photosensitive element converts the change of light intensity into a change of current, and sends out an alarm signal through the amplifying circuit.
  3. The aspirating smoke detector has changed the traditional way of waiting for the smoke to drift to the detector to detect passively, but adopts a new concept, that is to say, to actively sample and detect the air. The aspirating pump inside the gas-type smoke detector sucks into the sampling pipe and sends it to the detector for analysis. If smoke particles are found, an alarm will be issued.
Product reviews
Very reliable
5
Stella
Avatar
3/22/2026 7:28 PM
We installed this smoke detector in our warehouse, and the infrared photoelectric sensor is impressively sensitive. Hardwired to the fire panel, it's been rock solid with zero false alarms.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews