Electromagnetic Relay, 3PDT, 12/24/48/110/220V

$57.51
High power electromagnetic relay, contact form 3PDT (3NO and 3NC), coil voltage of 12V DC/ 24V DC/ 48V DC/ 24V AC/ 110V AC/ 220V AC for your choice, contact load 40A/ 30V DC 250V AC, 11 pins, plug-in terminals, compact and low price.
SKU: ATO-EMR-38F
*
Free Shipping
Delivery date: 6-12 days

Electromagnetic relay with 3NO + 3NC contact form, is widely applied in electronic equipment, communication equipment, automatic control system, instrument and meters, etc.

Specification

BasicsModelATO-JQX-38F (Relay with Socket)
Dimension (L*W*H)86×42×85mm
Weight30g
Ambient Temperature-25℃~+55℃
Terminal TypePlug-in
Number of Pins11
Technical ParametersContact Form3PDT (3NO + 3NC)
Contact MaterialSilver alloy
Contact Capacity (Resistive load)40A/30V DC, 40A/250V AC
Coil PowerDC 2.5W, AC 5VA
Coil Voltage (Optional)12V DC, 24V DC, 48V DC, 24V AC, 110V AC, 220V AC
Pick-up Voltage at 23℃≤38.40V DC, 88V AC
Drop-out Voltage at 23℃≤4.8V DC, 36V AC
Contact Resistance @6V DC 1A≤100MΩ
Dielectric StrengthBetween open contact1200V AC 50Hz/1min
Between coil & contact2500VAC 50Hz/1min
Leakage current≤1mA
Insulation Resistance (MΩ)1000MΩ at 500V DC

Connection Diagram

Connection Diagram of 3PDT 12/24/48V Electromagnetic Relay

Dimensions Diagram (Units: mm)

Dimensions Diagram of 3PDT 12/24/48V Electromagnetic Relay

Details

Electromagnetic Relay, 3PDT 12V-220V Details

Tips: What rated voltage of the electromagnetic relay should be chosen?

Electromagnetic relay is a kind of control relay which is used to increase the number of control loops or amplify signals. During operation, when the voltage of the coil reaches the specified value, the electromagnetic relay will operate. The contacts of the electromagnetic relay are prone to virtual connection fault, which often occurs during the operation of electrical control. It may not always appear, so this fault is difficult to judge. But when it does happen, it can lead to a major accident. This fault is caused by the change of the contact resistance of the control loop, which makes the actual voltage at both ends of the coil lower than 85% of the rated voltage, so that the circuit is out of control. However, what rated voltage of the electromagnetic relay should be chosen?

  • Try to avoid using low voltage below 12V as the control voltage, because in this low voltage circuit, the virtual contact fault is most likely to occur.
  • When the control circuit uses 24V as the control voltage, the parallel contact should be used to improve its working reliability.
  • When the control circuit must be controlled with low pressure, it is better to use 48V.
  • The control circuit had better use 110V and above voltage as the rated control voltage, which can effectively prevent the generation of virtual contact phenomenon.

Contactors are widely used in industrial equipment. It is a common application to control 110V/120V/220V/240V AC contactors with 12V/24V/36V DC relays. Users can use this method to control unsafe voltages. This video will show you how to use AC contactor with a relay at safe voltage.

Electromagnetic Relay Applications

Electromagnetic relays are key components in electrical engineering and play an important role in various applications. In this video, we will look at why electromagnetic relays are important in our lives.

In this video we will try to clear the confusion many people have between relays and contactors by showing you how to tell the difference based on five criteria: Definition, Capacity, Structure, Contacts and Applications.

Product reviews
High quality 3PDT electromagnetic relay
5
Hacoy
Avatar
11/14/2022 12:24 AM
I use this 3PDT electromagnetic relay to power a duct booster fan. The relay coil is powered by the terminals on my forced air unit. I had been using a pressure switch for this function.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Electromagnetic relay with 3NO + 3NC contact form, is widely applied in electronic equipment, communication equipment, automatic control system, instrument and meters, etc.

Specification

BasicsModelATO-JQX-38F (Relay with Socket)
Dimension (L*W*H)86×42×85mm
Weight30g
Ambient Temperature-25℃~+55℃
Terminal TypePlug-in
Number of Pins11
Technical ParametersContact Form3PDT (3NO + 3NC)
Contact MaterialSilver alloy
Contact Capacity (Resistive load)40A/30V DC, 40A/250V AC
Coil PowerDC 2.5W, AC 5VA
Coil Voltage (Optional)12V DC, 24V DC, 48V DC, 24V AC, 110V AC, 220V AC
Pick-up Voltage at 23℃≤38.40V DC, 88V AC
Drop-out Voltage at 23℃≤4.8V DC, 36V AC
Contact Resistance @6V DC 1A≤100MΩ
Dielectric StrengthBetween open contact1200V AC 50Hz/1min
Between coil & contact2500VAC 50Hz/1min
Leakage current≤1mA
Insulation Resistance (MΩ)1000MΩ at 500V DC

Connection Diagram

Connection Diagram of 3PDT 12/24/48V Electromagnetic Relay

Dimensions Diagram (Units: mm)

Dimensions Diagram of 3PDT 12/24/48V Electromagnetic Relay

Details

Electromagnetic Relay, 3PDT 12V-220V Details

Tips: What rated voltage of the electromagnetic relay should be chosen?

Electromagnetic relay is a kind of control relay which is used to increase the number of control loops or amplify signals. During operation, when the voltage of the coil reaches the specified value, the electromagnetic relay will operate. The contacts of the electromagnetic relay are prone to virtual connection fault, which often occurs during the operation of electrical control. It may not always appear, so this fault is difficult to judge. But when it does happen, it can lead to a major accident. This fault is caused by the change of the contact resistance of the control loop, which makes the actual voltage at both ends of the coil lower than 85% of the rated voltage, so that the circuit is out of control. However, what rated voltage of the electromagnetic relay should be chosen?

  • Try to avoid using low voltage below 12V as the control voltage, because in this low voltage circuit, the virtual contact fault is most likely to occur.
  • When the control circuit uses 24V as the control voltage, the parallel contact should be used to improve its working reliability.
  • When the control circuit must be controlled with low pressure, it is better to use 48V.
  • The control circuit had better use 110V and above voltage as the rated control voltage, which can effectively prevent the generation of virtual contact phenomenon.
Product reviews
High quality 3PDT electromagnetic relay
5
Hacoy
Avatar
11/14/2022 12:24 AM
I use this 3PDT electromagnetic relay to power a duct booster fan. The relay coil is powered by the terminals on my forced air unit. I had been using a pressure switch for this function.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews