Chlorine (Cl2) Monitor, 0 to 10/20/50/100 ppm

$433.99
Purchase portable Chlorine Cl2 detector at an economical price, with the diffusion sampling method, optional measuring ranges of 0-10ppm, 0-20ppm, 0-50ppm, 0-100ppm. It is a handheld gas monitor to detect Cl2 gas leak, ideal for personal and home use.
SKU: GD800-CL2
*
Free Shipping
Delivery date: 8-12 days

Low price portable gas detector provides real-time data, enabling timely interventions to prevent harmful exposure. This Chlorine gas monitor offers a measuring range from 0 to 100 ppm, making it ideal for detecting Cl2 concentrations in diverse settings.

Specification

ModelGD800-CL2
Detected gasChlorine (Cl2)
Sampling methodDiffusion
Range (optional)
0-10ppm, 0-20ppm, 0-50ppm, 0-100ppm
Resolution
0.1ppm
Response time≤10S (T90)
PrincipleElectrochemical principle
Alarm modeSound, light, vibration alarm, high and low alarm values can be set by yourself
Alarm typeLow alarm, high alarm, STEL, TWA, low battery
Power supply mode3.6V dry battery (non-removable and rechargeable)
Explosion-proof gradeII 1G Ex da ia IIC T4 Ga
Protection classIP68
Working temperature-20℃~55℃
Working humidity0~95%RH (non-condensing)
Working air pressure86~106kpa
Dimensions90*60*33mm (length*width*thickness)
Weight125g

Note 1:

  • If you require a Cl2 gas detector with a measuring range not listed in the table above, please contact us with details about your operating environment. We can help you choose the right detector for your application.

  • We also offer gas detectors for other common gases. Please refer to the ATO Gas Detector Catalog for available gas types and measuring ranges.

Note 2:

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.

Features

  • Exceptional energy efficiency and extended standby capability: Boasting remarkably low power consumption, This mini Cl2 tester offers a prolonged standby time of up to 2 years, eliminating the need for battery replacement.
  • Hassle-free maintenance: Simply power on the Chlorine gas monitor, and it will operate continuously without requiring calibration, sensor replacements, or battery charging.
  • Vigilant alarm system: Equipped with an ultra-high buzzer alarm, two high-intensity red LEDs for both upper and lower alarms, and a combination of sound, light, and vibration alerts, ensuring that workers are promptly alerted to potential dangers.
  • Customizable alarm settings: Supporting various alarm types such as high point alarm, low point alarm, TWA (Time-Weighted Average), and STEL (Short-Term Exposure Limit), users can easily adjust alarm thresholds as needed throughout the device's lifespan.
  • Rugged and secure design: This portable Cl2 gas detecstor boasts an IP68 protection rating, making it splash-proof, dust-proof, explosion-proof, and shock-proof. Its intrinsically safe circuit design enhances safety in hazardous environments.
  • User-friendly and compact: Designed for ease of use, it features a compact and lightweight design with intuitive two-button operation, reducing the need for extensive training.
  • Portability at its best: Its small size and lightweight build ensure that it can be carried with ease, providing flexibility in its use.
  • Built to last: Crafted from high-strength materials, the device's robust construction is tailored to endure the harshest environments while remaining comfortable and durable.
  • Enhanced safety features: Featuring an automatic self-test function, mini Cl2 gas detector continually ensures its own functionality, thereby improving safety by performing self-tests.

Structure

Mini portable Chlorine (Cl2) gas detector structure

Applications

Chlorine (Cl2) detectors are widely used in water treatment facilities to monitor Chlorine concentration and ensure water quality safety. In industrial manufacturing processes, especially in the chemical, pulp and paper industries, Cl2 gas monitors are used to detect and prevent Chlorine leaks to ensure worker safety. In addition, Chlorine is used in food disinfection and detergent production, so it is crucial to install Cl2 detectors in these locations. The Cl2 gas monitor prevents poisoning accidents and protects personnel health and environmental safety by providing timely warning of Chlorine gas leakage.

Mini Chlorine (Cl2) gas monitor applications

Tips: What are the safety benefits of using Chlorine monitors?

Portable Chlorine monitors offer several safety benefits in various industries where chlorine gas is used or produced. Firstly, they provide early detection of Chlorine leaks or spills, allowing prompt action to mitigate risks and prevent potential harm to personnel and the environment. By continuously monitoring Cl2 levels, these devices can trigger alarms when concentrations exceed safe thresholds, enabling rapid evacuation and response measures. Moreover, mini Chlorine gas detectors aid in ensuring compliance with regulatory standards for workplace safety, helping companies avoid fines and penalties. They also contribute to improving overall process safety by identifying potential equipment malfunctions or leaks before they escalate into major incidents. Ultimately, the use of Cl2 monitors enhances workplace safety culture by fostering awareness of Chlorine gas hazards and promoting proactive measures to minimize risks to personnel and facilities.

Basic Settings of Gas Detector

This video we're gonna guide you through some basic operational user functions.

How to Test a Small Handheld Single Gas Detector?

In this video, it is shown how to test a small handheld single gas detector. This is a simple safety device that everyone should have. It is small, easy to carry, lightweight and easy to use.

Product reviews
Economical and handy Chlorine (Cl2) monitor
5
Iruri
Avatar
7/8/2024 3:16 AM
This portable Chlorine (Cl2) Monitor is so perfect! The monitor is friendly for using, featuring a clear display and easy-to-navigate controls. In addition, this portable Chlorine (Cl2) Monitor has a compact size, and the price is also economical. Overall, I highly recommend this Cl2 monitor.
Was this review helpful? Yes No (0/0)
This chlorine monitor works great
5
Lisa
Avatar
5/24/2026 9:24 PM
I carry this chlorine monitor daily at our wastewater plant. The 0‑10ppm range alerts well before I ever smell anything. It's been dropped, splashed, and still works perfectly. Small enough to clip on my vest. Worth to buy.
Was this review helpful? Yes No (0/0)
Detecting chlorine concentration in oxygen
4
Motsey
Avatar
10/7/2026 2:24 AM
I need to detect the concentration of chlorine (Cl₂) in oxygen (O₂). The expected gas concentration range is 0–1000 ppm, with an ideal concentration of zero. The measurement range can be flexibly set (e.g., 0–100 ppm or 0–10,000 ppm), but the resolution must reach 0.1 ppm. Any recommendations?
Was this review helpful? Yes No (0/0)
ATO Responded
We need to know:
1. What are the temperature, humidity, and pressure of the gas exiting the electrolyzer? Is there any dehumidification pretreatment?
2. Is the actual Cl₂ concentration close to 0 ppm, or is a high concentration shock possible?
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Low price portable gas detector provides real-time data, enabling timely interventions to prevent harmful exposure. This Chlorine gas monitor offers a measuring range from 0 to 100 ppm, making it ideal for detecting Cl2 concentrations in diverse settings.

Specification

ModelGD800-CL2
Detected gasChlorine (Cl2)
Sampling methodDiffusion
Range (optional)
0-10ppm, 0-20ppm, 0-50ppm, 0-100ppm
Resolution
0.1ppm
Response time≤10S (T90)
PrincipleElectrochemical principle
Alarm modeSound, light, vibration alarm, high and low alarm values can be set by yourself
Alarm typeLow alarm, high alarm, STEL, TWA, low battery
Power supply mode3.6V dry battery (non-removable and rechargeable)
Explosion-proof gradeII 1G Ex da ia IIC T4 Ga
Protection classIP68
Working temperature-20℃~55℃
Working humidity0~95%RH (non-condensing)
Working air pressure86~106kpa
Dimensions90*60*33mm (length*width*thickness)
Weight125g

Note 1:

  • If you require a Cl2 gas detector with a measuring range not listed in the table above, please contact us with details about your operating environment. We can help you choose the right detector for your application.

  • We also offer gas detectors for other common gases. Please refer to the ATO Gas Detector Catalog for available gas types and measuring ranges.

Note 2:

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.

Features

  • Exceptional energy efficiency and extended standby capability: Boasting remarkably low power consumption, This mini Cl2 tester offers a prolonged standby time of up to 2 years, eliminating the need for battery replacement.
  • Hassle-free maintenance: Simply power on the Chlorine gas monitor, and it will operate continuously without requiring calibration, sensor replacements, or battery charging.
  • Vigilant alarm system: Equipped with an ultra-high buzzer alarm, two high-intensity red LEDs for both upper and lower alarms, and a combination of sound, light, and vibration alerts, ensuring that workers are promptly alerted to potential dangers.
  • Customizable alarm settings: Supporting various alarm types such as high point alarm, low point alarm, TWA (Time-Weighted Average), and STEL (Short-Term Exposure Limit), users can easily adjust alarm thresholds as needed throughout the device's lifespan.
  • Rugged and secure design: This portable Cl2 gas detecstor boasts an IP68 protection rating, making it splash-proof, dust-proof, explosion-proof, and shock-proof. Its intrinsically safe circuit design enhances safety in hazardous environments.
  • User-friendly and compact: Designed for ease of use, it features a compact and lightweight design with intuitive two-button operation, reducing the need for extensive training.
  • Portability at its best: Its small size and lightweight build ensure that it can be carried with ease, providing flexibility in its use.
  • Built to last: Crafted from high-strength materials, the device's robust construction is tailored to endure the harshest environments while remaining comfortable and durable.
  • Enhanced safety features: Featuring an automatic self-test function, mini Cl2 gas detector continually ensures its own functionality, thereby improving safety by performing self-tests.

Structure

Mini portable Chlorine (Cl2) gas detector structure

Applications

Chlorine (Cl2) detectors are widely used in water treatment facilities to monitor Chlorine concentration and ensure water quality safety. In industrial manufacturing processes, especially in the chemical, pulp and paper industries, Cl2 gas monitors are used to detect and prevent Chlorine leaks to ensure worker safety. In addition, Chlorine is used in food disinfection and detergent production, so it is crucial to install Cl2 detectors in these locations. The Cl2 gas monitor prevents poisoning accidents and protects personnel health and environmental safety by providing timely warning of Chlorine gas leakage.

Mini Chlorine (Cl2) gas monitor applications

Tips: What are the safety benefits of using Chlorine monitors?

Portable Chlorine monitors offer several safety benefits in various industries where chlorine gas is used or produced. Firstly, they provide early detection of Chlorine leaks or spills, allowing prompt action to mitigate risks and prevent potential harm to personnel and the environment. By continuously monitoring Cl2 levels, these devices can trigger alarms when concentrations exceed safe thresholds, enabling rapid evacuation and response measures. Moreover, mini Chlorine gas detectors aid in ensuring compliance with regulatory standards for workplace safety, helping companies avoid fines and penalties. They also contribute to improving overall process safety by identifying potential equipment malfunctions or leaks before they escalate into major incidents. Ultimately, the use of Cl2 monitors enhances workplace safety culture by fostering awareness of Chlorine gas hazards and promoting proactive measures to minimize risks to personnel and facilities.

Product reviews
Economical and handy Chlorine (Cl2) monitor
5
Iruri
Avatar
7/8/2024 3:16 AM
This portable Chlorine (Cl2) Monitor is so perfect! The monitor is friendly for using, featuring a clear display and easy-to-navigate controls. In addition, this portable Chlorine (Cl2) Monitor has a compact size, and the price is also economical. Overall, I highly recommend this Cl2 monitor.
Was this review helpful? Yes No (0/0)
This chlorine monitor works great
5
Lisa
Avatar
5/24/2026 9:24 PM
I carry this chlorine monitor daily at our wastewater plant. The 0‑10ppm range alerts well before I ever smell anything. It's been dropped, splashed, and still works perfectly. Small enough to clip on my vest. Worth to buy.
Was this review helpful? Yes No (0/0)
Detecting chlorine concentration in oxygen
4
Motsey
Avatar
10/7/2026 2:24 AM
I need to detect the concentration of chlorine (Cl₂) in oxygen (O₂). The expected gas concentration range is 0–1000 ppm, with an ideal concentration of zero. The measurement range can be flexibly set (e.g., 0–100 ppm or 0–10,000 ppm), but the resolution must reach 0.1 ppm. Any recommendations?
Was this review helpful? Yes No (0/0)
ATO Responded
We need to know:
1. What are the temperature, humidity, and pressure of the gas exiting the electrolyzer? Is there any dehumidification pretreatment?
2. Is the actual Cl₂ concentration close to 0 ppm, or is a high concentration shock possible?
Only registered users can write reviews
Customers who bought this item also bought

Fixed Chlorine (Cl2) Gas Detector, 0 to 10/50/100ppm

GD300-CL2
$608.44
Specially price chlorine (Cl2) fixed gas detector that provides unparalleled chlorine gas concentration measurement to ensure users a safe working environment. Acoustic and electric gas alarm, second-level response, immediate alarm, selected materials, can measure 0-10, 0-20, 0-50, 0-100ppm, and can operate for a long time under harsh conditions.