Humidity Sensor, Capacitive, Analog Output 0-3V

$37.42
Capacitive humidity sensor is a 3-wire humidity sensor with high accuracy, good long-term stability, small size, long signal transmission distance above 20m. Humidity sensor has linear analog voltage output 0-3V. A hole on the top of humidity sensor for wall mounting.
SKU: ATO-TAHS-AM2001
This product has a minimum quantity of 3
Free Shipping
Delivery date: 6-12 days

Humidity sensor with 0-3V output signal is easy to connect with dual channel temperature controller for temperature and humidity monitoring.

Application: Humidity sensor is widely used in HVAC, dehumidifiers, automobile, data loggers, humidity regulators, and humidity detection and control system.
Specification:

ItemAM1011A
Weight14g
Dimension (L*W*H)26.7*13.8*58.8mm
Output signal0-3V
Power supplyDC 4.75-5.25V
Measuring range of relative humidity0~99.9%RH
Measuring range of temperature-40~+80℃
Accuracy of humidity±3%RH
Accuracy of temperature±0.5℃
Power consumption≤2mA
Housing materialABS
Working environmentTemperature: -40~80℃, humidity: 0~99.9% no condensation
Storage environmentTemperature: 0~80℃, humidity: <95%RH
Cable length25cm (customized cable length ≤20m)
Wiring1 red: VDD (power supply), 2 yellow: Hout (humidity output 0-3V), 3 black: GND (ground), 4 Gray: Tout (Temperature is NTC 10K)

Dimensional drawing (unit: mm):
Capacitive humidity sensor analog output 0-3V dimension
Pin assignment:
Capacitive humidity sensor 0-3V pin- assignment

Product reviews
Regarding the temperature output signal
5
Cack
Avatar
8/1/2024 12:19 AM
I have a question regarding the temperature output signal on a humidity sensor, SKU: ATO-TAHS-AM2001. Is it required to connect the temperature signal to a data logger to obtain an accurate relative humidity reading?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, you need to connect the temperature signal to the data logger to get an accurate relative humidity reading, you cannot connect the humidity signal alone.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Humidity sensor with 0-3V output signal is easy to connect with dual channel temperature controller for temperature and humidity monitoring.

Application: Humidity sensor is widely used in HVAC, dehumidifiers, automobile, data loggers, humidity regulators, and humidity detection and control system.
Specification:

ItemAM1011A
Weight14g
Dimension (L*W*H)26.7*13.8*58.8mm
Output signal0-3V
Power supplyDC 4.75-5.25V
Measuring range of relative humidity0~99.9%RH
Measuring range of temperature-40~+80℃
Accuracy of humidity±3%RH
Accuracy of temperature±0.5℃
Power consumption≤2mA
Housing materialABS
Working environmentTemperature: -40~80℃, humidity: 0~99.9% no condensation
Storage environmentTemperature: 0~80℃, humidity: <95%RH
Cable length25cm (customized cable length ≤20m)
Wiring1 red: VDD (power supply), 2 yellow: Hout (humidity output 0-3V), 3 black: GND (ground), 4 Gray: Tout (Temperature is NTC 10K)

Dimensional drawing (unit: mm):
Capacitive humidity sensor analog output 0-3V dimension
Pin assignment:
Capacitive humidity sensor 0-3V pin- assignment

Product reviews
Regarding the temperature output signal
5
Cack
Avatar
8/1/2024 12:19 AM
I have a question regarding the temperature output signal on a humidity sensor, SKU: ATO-TAHS-AM2001. Is it required to connect the temperature signal to a data logger to obtain an accurate relative humidity reading?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, you need to connect the temperature signal to the data logger to get an accurate relative humidity reading, you cannot connect the humidity signal alone.
Only registered users can write reviews