Benchtop pH Meter for Water Quality, pH/ORP/TDS

$195.88
Benchtop pH meter for water quality sold at a discount, has wide test range pH from 0.00 to 14.00, EC from 0.00 to 19.99 mS/cm, ORP from -1999 to 1999 mV, CF from 0.0 to 199.9 CF, temperature from 0°C to 100°C, and TDS from 10 to 19990 ppm. The pH detector is ideal for applications in laboratories, water treatment facilities, hydroponics, and environmental monitoring.
SKU: ATO-PHM-26C
Free Shipping
Delivery date: 6-12 days

The ph instrument has a 4-digit LCD display for easy reading of pH, EC, and TDS values, along with a 3-digit display for temperature. The ph tester is equipped with automatic temperature compensation for consistent accuracy between 0°C and 50°C.

Specification

ModelATO-PHS-26C
RangePH:  0.00~14.00PH, EC: 0.00~19.99ms/cm, ORP: -1999~1999mV, CF: 0.0~199.9CF, Temp: 0~100°C, TDS: 10~19990ppm
ResolutionPH: 0.01PH, EC: 0.01ms/cm, ORP: 1mV, CF: 0.1CF, Temp: 0.1°C, TDS: 10ppm
AccuracyPH: ±0.01PH, ORP: ±1mV, Temp: ±0.5°C
EC/CF/TDS±2% F.S
DisplayPH: 4-digit LCD, Temp: 3-digit LCD
Automatic Temperature Compensation0°C ~ 50°C
CalibrationManual two-points
Power SupplyAC220V


Feature

Benchtop pH meter for water quality feature

  • High-Definition LCD Display: The large, clear display provides easy-to-read values, ensuring suitability for a range of industrial testing applications.
  • Flexible Interface Design: With detachable probes and a portable power supply, it offers enhanced convenience for transport and use, boosting practicality.
  • High-Precision Electrode: Featuring a durable, long-lasting electrode, this device guarantees accurate measurements and long service life.
  • Simple Operation: Built for ease of use, the intuitive design allows for quick operation, ensuring a seamless user experience and easy learning curve.
  • Automatic Temperature Compensation: This function ensures accurate readings across varying temperatures, enhancing reliability.
  • Data Storage Capability: The built-in data storage feature enables efficient saving of measurement records for future analysis and review.
  • Manual Calibration: The manual calibration option ensures long-term accuracy and stability, maintaining precise measurements over time.

Dimension and Introduction of Interface

Benchtop pH meter for water quality size

1. Screen Display2. ORP Function Key3. pH Function4. Temperature Function Key5. EC/CF/TDS Function Switch Key6. pH7 Calibration Knob7. pH4 Calibration Knob
8. EC/CF/TDS Calibration Knob9. EC Electrode Input Terminal10. AC Input Terminal11. DC or RB Power Switch12. pH/ORP Electrode Input Terminal13. Temperature Electrode Input Terminal/


Application

Benchtop pH meter for water quality application

Tips: What is ORP, and why is it important for water quality testing?

ORP stands for Oxidation-Reduction Potential and is a measure of the water’s ability to either release or accept electrons during chemical reactions. It’s used to evaluate the disinfecting power of the water, particularly in processes like water treatment and swimming pool management. Higher ORP levels indicate a better ability to break down contaminants through oxidation, making it an essential parameter for assessing water’s overall health and safety.

Product reviews
Calibration Solutions
5
Portus
Avatar
9/14/2026 1:08 AM
Hello, please confirm the specific pH and EC/TDS calibration solutions recommended for this meter.
Was this review helpful? Yes No (0/0)
ATO Responded
For pH calibration, the recommended values are pH 4.01, 7.00, and 10.01. For conductivity (EC), 1413 μS/cm is recommended. For TDS, 342 ppm (NaCl) is recommended.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

The ph instrument has a 4-digit LCD display for easy reading of pH, EC, and TDS values, along with a 3-digit display for temperature. The ph tester is equipped with automatic temperature compensation for consistent accuracy between 0°C and 50°C.

Specification

ModelATO-PHS-26C
RangePH:  0.00~14.00PH, EC: 0.00~19.99ms/cm, ORP: -1999~1999mV, CF: 0.0~199.9CF, Temp: 0~100°C, TDS: 10~19990ppm
ResolutionPH: 0.01PH, EC: 0.01ms/cm, ORP: 1mV, CF: 0.1CF, Temp: 0.1°C, TDS: 10ppm
AccuracyPH: ±0.01PH, ORP: ±1mV, Temp: ±0.5°C
EC/CF/TDS±2% F.S
DisplayPH: 4-digit LCD, Temp: 3-digit LCD
Automatic Temperature Compensation0°C ~ 50°C
CalibrationManual two-points
Power SupplyAC220V


Feature

Benchtop pH meter for water quality feature

  • High-Definition LCD Display: The large, clear display provides easy-to-read values, ensuring suitability for a range of industrial testing applications.
  • Flexible Interface Design: With detachable probes and a portable power supply, it offers enhanced convenience for transport and use, boosting practicality.
  • High-Precision Electrode: Featuring a durable, long-lasting electrode, this device guarantees accurate measurements and long service life.
  • Simple Operation: Built for ease of use, the intuitive design allows for quick operation, ensuring a seamless user experience and easy learning curve.
  • Automatic Temperature Compensation: This function ensures accurate readings across varying temperatures, enhancing reliability.
  • Data Storage Capability: The built-in data storage feature enables efficient saving of measurement records for future analysis and review.
  • Manual Calibration: The manual calibration option ensures long-term accuracy and stability, maintaining precise measurements over time.

Dimension and Introduction of Interface

Benchtop pH meter for water quality size

1. Screen Display2. ORP Function Key3. pH Function4. Temperature Function Key5. EC/CF/TDS Function Switch Key6. pH7 Calibration Knob7. pH4 Calibration Knob
8. EC/CF/TDS Calibration Knob9. EC Electrode Input Terminal10. AC Input Terminal11. DC or RB Power Switch12. pH/ORP Electrode Input Terminal13. Temperature Electrode Input Terminal/


Application

Benchtop pH meter for water quality application

Tips: What is ORP, and why is it important for water quality testing?

ORP stands for Oxidation-Reduction Potential and is a measure of the water’s ability to either release or accept electrons during chemical reactions. It’s used to evaluate the disinfecting power of the water, particularly in processes like water treatment and swimming pool management. Higher ORP levels indicate a better ability to break down contaminants through oxidation, making it an essential parameter for assessing water’s overall health and safety.

Product reviews
Calibration Solutions
5
Portus
Avatar
9/14/2026 1:08 AM
Hello, please confirm the specific pH and EC/TDS calibration solutions recommended for this meter.
Was this review helpful? Yes No (0/0)
ATO Responded
For pH calibration, the recommended values are pH 4.01, 7.00, and 10.01. For conductivity (EC), 1413 μS/cm is recommended. For TDS, 342 ppm (NaCl) is recommended.
Only registered users can write reviews