Air compressor pressure switch 240V equipped with relief valve pressure switch and four way base. Work in temperature -25℃~80℃. Rated voltage/current AC 240V/20A, AC 120V/26A. Widely used in air compressor, water pump, pressure gauge.
Specification
| Model | ATO-LF10-L1H | ATO-LF10-L4H |
| Interface standard | G1/4, G3/8 or 1/4, 3/8 inner screw | G1/4, G3/8 or 1/4, 3/8 NPT internal screw (cross) |
| Pressure adjustment range kgf/cm² | 3.0-12.5 | |
| Differential pressure (non-adjustable) kgf/cm² | 2.0/2.5/3.0 | |
| Factory setting kgf/cm² | 6.0-8.0 | |
| Rated voltage/current | 240VAC/20A 240VAC/26A | |
| Contact method | Normally closed | |
| Pressure setting | Closed 6.0 kgf/cm²; Opened 8.0 kgf/cm² | |
| Wiring | Threaded connection | |
| Shell material | Hardware, engineering plastics | |
| Protection function | Edge of safety | |
| Electrical life | 100,000 times | |
| 3C rated voltage range | 36V and below | |
| Operating temperature | -25℃~80℃ | |
| Warranty | 12 months | |
| Contact material | Silver | |
| Measuring range | 1~50kPa | |
Dimension (MM)

Feature
- Air compressor pressure switch equipped with compact shell made of hardware, engineering plastics, adopts aluminum oxidation process technology, easy installation, stable performance.
- Compressor pressure switch come with relief valve to avoid overload, long service life.
- Air compressor switch has electrical life 100,000 times, work in -25℃~80℃, rated voltage/current AC 240V/20A, AC 120V/26A.
- Four-way base, can make the installation of exhaust valve and pressure gauge easier, flat and smooth, not easy to damage, and the performance is more convenient and controllable
- A variety of air compressor pressure switch styles are available: single-way/four-way.
Special factory settings and differential pressure can be provided upon request. Other interfaces can be customized according to customer requirements. Unit conversion: 1kgf/cm2= 14.2psi 1bar=14.5psi
Details

Tips: What is the reason for the air compressor pressure switch leaking?
- If the pressure switch of the air compressor leaks air, first check whether it is caused by a failure of the one-way check valve, such as if it needs to be replaced in time.
- If it is not caused by the failure of the one-way check valve, then check whether the gasket of the one-way check valve is full of oil mist. If so, replace the gasket, or get a rubber pad of the same size and place it on the seal. The underside of the pad is reinforced to prevent air leakage.