8" Flanged Diaphragm Valve, UPVC/ CPVC

$1,710.39
Economical price 2 way PVC diaphragm valve with 8 inch (DN200) flanged port for flow and liquid control, available in UPVC and CPVC body material, PTFE diaphragm. This manual diaphragm valve is often found in water treatment, chemical processing and pharmaceuticals.
SKU: ATO-FDV-DN200
*
Free Shipping
Delivery date: 6-12 days

Note: This diaphragm valve cannot be used for drinking water.

2 way flanged PVC diaphragm valve is a type of industrial valve used to control the flow of fluids in pipelines, especially when it is essential to prevent the fluid from coming into contact with the valve components.

Specification

ModelATO-FDV-DN200
Size8 inch (DN200)
Structure TypeFlanged Type
Diaphragm Valve AssemblyPartsMaterial
DiaphragmPTFE
FilmEPDM
Valve BodyUPVC, CPVC
Valve PlateUPVC, CPVC, Steel, Stainless Steel
Cover LimitAS
StudSteel, Stainless Steel
Retaining NutFRPP
WasherFRPP
WheelAlloy Material
PlatenSteel, Stainless Steel
Double-Headed Stud and NutSteel, Stainless Steel
BonnetUPVC, CPVC
Yoke NutHt300 Steel
StemSteel, Stainless Steel


Dimension (Unit: mm)

Flanged PVC diaphragm valve dimension DN15 ~ DN100

SizeValve Body MaterialdDLhn-φ
8 inch (DN200)UPVC300340580408-φ23
CPVC300340575408-φ23

Note: The above dimensions are for reference only, please refer to the actual product.

Detail

Flanged diaphragm valve detail

Working Pressure

SizeWorking Pressure (MPa)
UPVCCPVC
20~40℃41~60℃61~80℃0~40℃41~60℃61~90℃
1/2" (DN15)0.80.80.70.70.70.6
3/4" (DN20)0.80.80.70.70.70.6
1" (DN25)0.80.80.70.70.70.6
1-1/4" (DN32)0.70.70.60.70.70.6
1-1/2" (DN40)0.70.70.60.70.70.5
2" (DN50)0.70.70.60.70.70.5
2-1/2" (DN65)0.70.70.60.70.70.5
3" (DN80)0.70.70.60.70.70.5
4" (DN100)0.70.70.60.70.60.5
5" (DN125)0.50.50.40.50.50.4
6" (DN150)0.50.50.40.50.40.3
8" (DN200)0.30.30.20.50.30.25
10" (DN250)0.30.30.20.30.30.2

Tips: How does a flanged diaphragm valve work?

A flanged diaphragm valve is a type of industrial valve designed to control the flow of fluids. It operates using a flexible diaphragm, which is a membrane that separates the valve body into two chambers. The diaphragm is typically made of rubber or similar materials.

In a closed position, the diaphragm creates a seal, preventing fluid flow. When the valve needs to be opened, a mechanism such as a handwheel or actuator applies force to the diaphragm, causing it to flex and deform. As the diaphragm moves, it uncovers the flow path, allowing the fluid to pass through. This design provides excellent sealing properties and prevents leakage since the diaphragm isolates the fluid from the valve components. Flanged connections make it easy to install the valve in pipelines.

Flanged diaphragm valves are commonly used in applications requiring precise flow control, such as in the chemical, pharmaceutical, and water treatment industries. Their simplicity and reliable sealing make them suitable for various corrosive and abrasive media.

Proposition 65 Warning

*WARNING: This product can expose you to chemicals, including lead, which is known to the State of California to cause birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.

Product reviews
Cavitation coefficient
5
Kuoli
Avatar
8/10/2026 1:35 AM
We recently purchased this valve (model ATO-FDV-DN200) and are currently collecting technical data for all components used in this project. Please provide the cavitation coefficient of this valve.
Was this review helpful? Yes No (0/0)
ATO Responded
Regarding the cavitation coefficient: Plastic diaphragm valves (UPVC/CPVC material) are primarily used for media shut-off and basic flow regulation, not as high-pressure differential throttling control valves. Therefore, the cavitation coefficient is generally not provided separately in technical specifications and test reports. If an assessment of cavitation risk in the system is required, it is recommended to calculate it based on actual operating conditions.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Note: This diaphragm valve cannot be used for drinking water.

2 way flanged PVC diaphragm valve is a type of industrial valve used to control the flow of fluids in pipelines, especially when it is essential to prevent the fluid from coming into contact with the valve components.

Specification

ModelATO-FDV-DN200
Size8 inch (DN200)
Structure TypeFlanged Type
Diaphragm Valve AssemblyPartsMaterial
DiaphragmPTFE
FilmEPDM
Valve BodyUPVC, CPVC
Valve PlateUPVC, CPVC, Steel, Stainless Steel
Cover LimitAS
StudSteel, Stainless Steel
Retaining NutFRPP
WasherFRPP
WheelAlloy Material
PlatenSteel, Stainless Steel
Double-Headed Stud and NutSteel, Stainless Steel
BonnetUPVC, CPVC
Yoke NutHt300 Steel
StemSteel, Stainless Steel


Dimension (Unit: mm)

Flanged PVC diaphragm valve dimension DN15 ~ DN100

SizeValve Body MaterialdDLhn-φ
8 inch (DN200)UPVC300340580408-φ23
CPVC300340575408-φ23

Note: The above dimensions are for reference only, please refer to the actual product.

Detail

Flanged diaphragm valve detail

Working Pressure

SizeWorking Pressure (MPa)
UPVCCPVC
20~40℃41~60℃61~80℃0~40℃41~60℃61~90℃
1/2" (DN15)0.80.80.70.70.70.6
3/4" (DN20)0.80.80.70.70.70.6
1" (DN25)0.80.80.70.70.70.6
1-1/4" (DN32)0.70.70.60.70.70.6
1-1/2" (DN40)0.70.70.60.70.70.5
2" (DN50)0.70.70.60.70.70.5
2-1/2" (DN65)0.70.70.60.70.70.5
3" (DN80)0.70.70.60.70.70.5
4" (DN100)0.70.70.60.70.60.5
5" (DN125)0.50.50.40.50.50.4
6" (DN150)0.50.50.40.50.40.3
8" (DN200)0.30.30.20.50.30.25
10" (DN250)0.30.30.20.30.30.2

Tips: How does a flanged diaphragm valve work?

A flanged diaphragm valve is a type of industrial valve designed to control the flow of fluids. It operates using a flexible diaphragm, which is a membrane that separates the valve body into two chambers. The diaphragm is typically made of rubber or similar materials.

In a closed position, the diaphragm creates a seal, preventing fluid flow. When the valve needs to be opened, a mechanism such as a handwheel or actuator applies force to the diaphragm, causing it to flex and deform. As the diaphragm moves, it uncovers the flow path, allowing the fluid to pass through. This design provides excellent sealing properties and prevents leakage since the diaphragm isolates the fluid from the valve components. Flanged connections make it easy to install the valve in pipelines.

Flanged diaphragm valves are commonly used in applications requiring precise flow control, such as in the chemical, pharmaceutical, and water treatment industries. Their simplicity and reliable sealing make them suitable for various corrosive and abrasive media.

Product reviews
Cavitation coefficient
5
Kuoli
Avatar
8/10/2026 1:35 AM
We recently purchased this valve (model ATO-FDV-DN200) and are currently collecting technical data for all components used in this project. Please provide the cavitation coefficient of this valve.
Was this review helpful? Yes No (0/0)
ATO Responded
Regarding the cavitation coefficient: Plastic diaphragm valves (UPVC/CPVC material) are primarily used for media shut-off and basic flow regulation, not as high-pressure differential throttling control valves. Therefore, the cavitation coefficient is generally not provided separately in technical specifications and test reports. If an assessment of cavitation risk in the system is required, it is recommended to calculate it based on actual operating conditions.
Only registered users can write reviews