7 kVA Isolation Transformer, 3 phase, 380V to 208V

$2,021.86
7 kVA isolation transformer is a step up or step down transformer in low cost, 3 phase, convert primary voltage 380V to secondary voltage 208V, better dielectric strength and insulation resistance.
SKU: ATO-T-SG7KVA
*
*
*
*
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Delivery date: 10-16 days

ATOSG-7KVA isolation transformer is a three phase unit with 7 kVA rating and primary voltage of 380V AC on the primary side. This transformer has a secondary voltage of 208V AC on the secondary side. It is designed for use in control circuits and general applications such as mechanical and electronic equipment, precision machine tool, CNC machine tool, lighting, etc.

7 kVA Isolation Transformer Specifications

BasicsModelATO-SG7KVA
Phase3 phase
Capacity7 kVA
Weight of Aluminium Wire TransformerOpen type: 65kg
Protected type: 81kg
Weight of Copper Wire TransformerOpen type: 58kg
Protected type: 71kg
Technical ParametersPrimary Voltage380V (Optional: 120V/ 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Secondary Voltage208V (Optional: 120V/ 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Frequency50Hz / 60 Hz
Winding MaterialAluminium/Copper wire (Optional)
Work Efficiency≥95%
Insulation Resistance≥50 MΩ
Electrical Strength3000V AC/1 min
Noise<35-65dB (1 meter)
Insulation GradeH level
Wiring ModeDyn11
Cooling ModeDry type air cooling
Overload CapacityAllow more than 1.2 times rated load to work for up to 4 hours
Enclosure Protection GradeIP 24
CertificateCE, ISO
Warranty12 months
Working EnvironmentTemperature-15℃~+40℃
Humidity≤90%RH, without condensation
Altitude<1000m, non corrosive gas and conductive dust

Note:

Transformer can only convert voltage and CANNOT convert frequency.
Transformer CANNOT convert single phase voltage to 3 phase voltage.
Input/output voltage, power rating and whether with shell of all transformers, can be customized according to clients' requirements.

3 Phase Isolation Transformer Schematic Diagram

ATO isolation transformers schematic diagram

3 Phase Isolation Transformer Details

3-phase isolation transformer details

7 kVA Isolation Transformer Installation Dimension

3 phase isolation transformer dimension

Aluminium Wire Transformer SizeCopper Wire Transformer Size
Open type: a*b*c=380*220*380mmOpen type: a*b*c=300*170*310mm
Mouting size: d*e=260*130mmMouting size: d*e=180*140mm
Protected type: A*B*C=380*530*560mmProtected type: A*B*C=300*440*500mm

Tips: What circumstance the isolation transformer must stop running?

ATO step up/down isolation transformer should be stopped immediately if one of the following situations occurs:

  1. Noise inside the isolation transformer is very large, very abnormal and has crackle sound.
  2. Under normal load and cooling conditions, the upper oil temperature of the transformer is abnormal and keeps rising.
  3. Expansion tank occurs or explosion-proof tube injects fuel.
  4. Serious oil leakage occurs, resulting in the oil level lower than the oil level indicator limit.
  5. Oil color changes too much, there is carbon in the oil.
  6. Casing has serious damage and electric discharge phenomena.
  7. Isolation transformer catches fire.
  8. Casing connector and lead turns red, melted or fused.

How to Test Step Up & Step Down Isolation Transformer?

Need more detail of ATO isolation transformer? Here is a good explanation about it in this video. To test the accuracy of the transformer voltage, we take a 3000 VA single phase 220V iuput to 110V output isolation transformer as an example.

Product reviews
What is your isolation transformer input voltage tolerance?
5
Farman Pannah
Avatar
12/29/2019 10:57 PM
I need a step down isolation transformer and this 7kVA capacity unit is what I am looking for. I want to know what is your isolation transformer input voltage tolerance?
Was this review helpful? Yes No (0/0)
ATO Responded
The transformer input voltage tolerance is +/- 5%.
The manufacture made the tolerance 5% Not 10%, just to keep transformer output voltage around required standard secondary voltage. As you know for transformers, the output voltage is changed automatically with the input voltage change.
Why is the votage between two hot of isolation transformer 400V?
5
duran
Avatar
5/10/2023 12:52 AM
Attached is a photo of the nameplate. Below is a photo of the field wiring listed inside the transformer.
On the low side there are three hot wires and one neutral. The measured voltages match the diagram that I provided. Between neutral and any of the hot is 230V, but between two hot it is 400V.
Was this review helpful? Yes No (0/0)
ATO Responded
According to the nameplate of the transformer you provided, we believe that the voltage between the two live wires is 230V.
Regarding the "between two hot it is 400V" you mentioned, please provide us with your measurement video or picture for further confirmation.
You can send us the large video file via we transfer.com. Thank you for your understanding.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

ATOSG-7KVA isolation transformer is a three phase unit with 7 kVA rating and primary voltage of 380V AC on the primary side. This transformer has a secondary voltage of 208V AC on the secondary side. It is designed for use in control circuits and general applications such as mechanical and electronic equipment, precision machine tool, CNC machine tool, lighting, etc.

7 kVA Isolation Transformer Specifications

BasicsModelATO-SG7KVA
Phase3 phase
Capacity7 kVA
Weight of Aluminium Wire TransformerOpen type: 65kg
Protected type: 81kg
Weight of Copper Wire TransformerOpen type: 58kg
Protected type: 71kg
Technical ParametersPrimary Voltage380V (Optional: 120V/ 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Secondary Voltage208V (Optional: 120V/ 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Frequency50Hz / 60 Hz
Winding MaterialAluminium/Copper wire (Optional)
Work Efficiency≥95%
Insulation Resistance≥50 MΩ
Electrical Strength3000V AC/1 min
Noise<35-65dB (1 meter)
Insulation GradeH level
Wiring ModeDyn11
Cooling ModeDry type air cooling
Overload CapacityAllow more than 1.2 times rated load to work for up to 4 hours
Enclosure Protection GradeIP 24
CertificateCE, ISO
Warranty12 months
Working EnvironmentTemperature-15℃~+40℃
Humidity≤90%RH, without condensation
Altitude<1000m, non corrosive gas and conductive dust

Note:

Transformer can only convert voltage and CANNOT convert frequency.
Transformer CANNOT convert single phase voltage to 3 phase voltage.
Input/output voltage, power rating and whether with shell of all transformers, can be customized according to clients' requirements.

3 Phase Isolation Transformer Schematic Diagram

ATO isolation transformers schematic diagram

3 Phase Isolation Transformer Details

3-phase isolation transformer details

7 kVA Isolation Transformer Installation Dimension

3 phase isolation transformer dimension

Aluminium Wire Transformer SizeCopper Wire Transformer Size
Open type: a*b*c=380*220*380mmOpen type: a*b*c=300*170*310mm
Mouting size: d*e=260*130mmMouting size: d*e=180*140mm
Protected type: A*B*C=380*530*560mmProtected type: A*B*C=300*440*500mm

Tips: What circumstance the isolation transformer must stop running?

ATO step up/down isolation transformer should be stopped immediately if one of the following situations occurs:

  1. Noise inside the isolation transformer is very large, very abnormal and has crackle sound.
  2. Under normal load and cooling conditions, the upper oil temperature of the transformer is abnormal and keeps rising.
  3. Expansion tank occurs or explosion-proof tube injects fuel.
  4. Serious oil leakage occurs, resulting in the oil level lower than the oil level indicator limit.
  5. Oil color changes too much, there is carbon in the oil.
  6. Casing has serious damage and electric discharge phenomena.
  7. Isolation transformer catches fire.
  8. Casing connector and lead turns red, melted or fused.
Product reviews
What is your isolation transformer input voltage tolerance?
5
Farman Pannah
Avatar
12/29/2019 10:57 PM
I need a step down isolation transformer and this 7kVA capacity unit is what I am looking for. I want to know what is your isolation transformer input voltage tolerance?
Was this review helpful? Yes No (0/0)
ATO Responded
The transformer input voltage tolerance is +/- 5%.
The manufacture made the tolerance 5% Not 10%, just to keep transformer output voltage around required standard secondary voltage. As you know for transformers, the output voltage is changed automatically with the input voltage change.
Why is the votage between two hot of isolation transformer 400V?
5
duran
Avatar
5/10/2023 12:52 AM
Attached is a photo of the nameplate. Below is a photo of the field wiring listed inside the transformer.
On the low side there are three hot wires and one neutral. The measured voltages match the diagram that I provided. Between neutral and any of the hot is 230V, but between two hot it is 400V.
Was this review helpful? Yes No (0/0)
ATO Responded
According to the nameplate of the transformer you provided, we believe that the voltage between the two live wires is 230V.
Regarding the "between two hot it is 400V" you mentioned, please provide us with your measurement video or picture for further confirmation.
You can send us the large video file via we transfer.com. Thank you for your understanding.