60A 100V 6000W Variable DC Power Supply

$2,630.68
6000W variable DC power supply with 0–100V output voltage and 0–60A output current, single-phase AC 220V input, digital voltage and current displays, potentiometer adjustment, and built-in overvoltage, overcurrent, and overtemperature protection.
SKU: ATO-VDCPS10060K
*
Free Shipping
Delivery date: 6-12 days

Adjustable DC power supply designed for stable and flexible power control, with independent voltage and current adjustment via potentiometers. Features 3½-digit digital metering, forced-air cooling, and comprehensive protection against overload, short circuits, overvoltage, and overheating.

Specification

ModelATO-JK10060K
Input VoltageSingle Phase 110V or 220V AC (±10%)
Input Frequency50/60 Hz
Output VoltageDC 0–100V
Output Current0–60A
Output Power6000 W
Power Supply Stability≤0.5% + 10 mV
Load Regulation≤0.5% + 30 mV
Ripple≤1% + 10 mV RMS
Voltage Display3½-digit digital meter;
Accuracy: ±0.5% FS + 1 digit (10%–100% of rated value);
Display range: 00.0–100.0V
Current Display3½-digit digital meter;
Accuracy: ±0.5% FS + 1 digit (10%–100% of rated value);
Display range: 00.0–60.0A
Insulation ResistanceInput-Output: ≥20 MΩ;
Input-Case: ≥20 MΩ;
Output-Case: ≥80 MΩ
Dielectric StrengthInput-Output: AC 1500V, 10mA, 1 minute;
Input-Case: AC 1500V, 10mA, 1 minute;
Output-Case: AC 1500V, 10mA, 1 minute
Overvoltage ProtectionBuilt-in OVP; protection threshold: rated output voltage +5%
Overcurrent ProtectionConstant-current output under overload and short-circuit conditions
Overtemperature ProtectionBuilt-in OTP; protection threshold: 85°C ±5°C (heatsink temperature)
Voltage and Current AdjustmentPotentiometer
Output PolarityPositive (+) and negative (-) outputs can be grounded independently
Cooling MethodForced-Air Cooling
Operating EnvironmentIndoor use;
Temperature: -10°C–60°C;
Humidity: 10%–85% RH
Storage EnvironmentTemperature: -20–70°C;
Humidity: 10%–90% RH
Size430 (L) x 450 (W) x 180 (H) mm
Weight28kg

Note: All values are typical and may vary under different load conditions or operating circumstances. Accuracy is measured under load-side voltage sensing conditions. Deviations from rated values may occur due to temperature variations and component aging.

Feature

  • High-Power DC Output: The 6000W power supply provides stable and reliable DC power for demanding electronic equipment, testing systems, laboratory setups, and other high-power applications.
  • Independent Voltage & Current Adjustment: Separate controls allow you to fine-tune the output voltage and current according to different load and testing requirements.
  • Automatic CV/CC Mode: Automatically switches between constant voltage (CV) and constant current (CC) operation to maintain regulated output as load conditions change.
  • Stable, Low-Ripple Output: Delivers clean and consistent DC power with low ripple, making the unit suitable for sensitive electronic circuits and precision testing applications.
  • Built-In Protection: Overvoltage, overcurrent, short-circuit, and overtemperature protection help safeguard the power supply and connected equipment during abnormal operating conditions.
  • Digital Monitoring: The adjustable DC power supply features 3½-digit digital meters for clear, real-time monitoring of output voltage and current.

Detail

Front

60A 100V variable DC power supply detail

Back

60A 100V variable DC power supply detail

Size (unit: mm)

60A 100V variable DC power supply size

Tips: How Do I Set Voltage and Current on a 6000W Variable DC Power Supply?

Before connecting the load, check the equipment's rated voltage and maximum current requirements. Set the output voltage according to the load specification, then adjust the current limit based on its operating requirements. For this 6000W variable DC power supply, make sure the selected settings stay within the 100V maximum voltage and 60A maximum current ratings. For sensitive electronics, verify the output polarity and monitor the digital voltage and current readings during initial power-up.

Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Adjustable DC power supply designed for stable and flexible power control, with independent voltage and current adjustment via potentiometers. Features 3½-digit digital metering, forced-air cooling, and comprehensive protection against overload, short circuits, overvoltage, and overheating.

Specification

ModelATO-JK10060K
Input VoltageSingle Phase 110V or 220V AC (±10%)
Input Frequency50/60 Hz
Output VoltageDC 0–100V
Output Current0–60A
Output Power6000 W
Power Supply Stability≤0.5% + 10 mV
Load Regulation≤0.5% + 30 mV
Ripple≤1% + 10 mV RMS
Voltage Display3½-digit digital meter;
Accuracy: ±0.5% FS + 1 digit (10%–100% of rated value);
Display range: 00.0–100.0V
Current Display3½-digit digital meter;
Accuracy: ±0.5% FS + 1 digit (10%–100% of rated value);
Display range: 00.0–60.0A
Insulation ResistanceInput-Output: ≥20 MΩ;
Input-Case: ≥20 MΩ;
Output-Case: ≥80 MΩ
Dielectric StrengthInput-Output: AC 1500V, 10mA, 1 minute;
Input-Case: AC 1500V, 10mA, 1 minute;
Output-Case: AC 1500V, 10mA, 1 minute
Overvoltage ProtectionBuilt-in OVP; protection threshold: rated output voltage +5%
Overcurrent ProtectionConstant-current output under overload and short-circuit conditions
Overtemperature ProtectionBuilt-in OTP; protection threshold: 85°C ±5°C (heatsink temperature)
Voltage and Current AdjustmentPotentiometer
Output PolarityPositive (+) and negative (-) outputs can be grounded independently
Cooling MethodForced-Air Cooling
Operating EnvironmentIndoor use;
Temperature: -10°C–60°C;
Humidity: 10%–85% RH
Storage EnvironmentTemperature: -20–70°C;
Humidity: 10%–90% RH
Size430 (L) x 450 (W) x 180 (H) mm
Weight28kg

Note: All values are typical and may vary under different load conditions or operating circumstances. Accuracy is measured under load-side voltage sensing conditions. Deviations from rated values may occur due to temperature variations and component aging.

Feature

  • High-Power DC Output: The 6000W power supply provides stable and reliable DC power for demanding electronic equipment, testing systems, laboratory setups, and other high-power applications.
  • Independent Voltage & Current Adjustment: Separate controls allow you to fine-tune the output voltage and current according to different load and testing requirements.
  • Automatic CV/CC Mode: Automatically switches between constant voltage (CV) and constant current (CC) operation to maintain regulated output as load conditions change.
  • Stable, Low-Ripple Output: Delivers clean and consistent DC power with low ripple, making the unit suitable for sensitive electronic circuits and precision testing applications.
  • Built-In Protection: Overvoltage, overcurrent, short-circuit, and overtemperature protection help safeguard the power supply and connected equipment during abnormal operating conditions.
  • Digital Monitoring: The adjustable DC power supply features 3½-digit digital meters for clear, real-time monitoring of output voltage and current.

Detail

Front

60A 100V variable DC power supply detail

Back

60A 100V variable DC power supply detail

Size (unit: mm)

60A 100V variable DC power supply size

Tips: How Do I Set Voltage and Current on a 6000W Variable DC Power Supply?

Before connecting the load, check the equipment's rated voltage and maximum current requirements. Set the output voltage according to the load specification, then adjust the current limit based on its operating requirements. For this 6000W variable DC power supply, make sure the selected settings stay within the 100V maximum voltage and 60A maximum current ratings. For sensitive electronics, verify the output polarity and monitor the digital voltage and current readings during initial power-up.

Only registered users can write reviews