600VA (600W) full power toroidal transformer is a single phase general purpose transformer with a primary voltage of 240 V AC and a secondary voltages of 12V/24V, dual outputs versions like 30-0-30V, 40-0-40V are avalible. It offers a significant size and weight reducation as well as low cost and high reliability.
SKU: ATO-T-C600VA
*
*
Free Shipping
Delivery date: 6-12 days

Customized step up or step down toroidal transformers with 600VA capacity, 1-phase, a single 240V/50-60Hz primary winding, 12V/ 24V/ 2x50V AC secondary winding for selecting, manufactured, and tested in compliance with CE, RoHS, ISO standards.

Advantages of ATO Toroidal Transformer

  1. High Efficiency: Winding matches the core perfectly, which makes the transformer more efficient.
  2. Long Service Life: With high-quality materials and manufacturing technology, the transformer can be used for 30 years.
  3. Less Noise: The core is seamlessly rolled and the winding is set evenly over it, which makes the transformer quiet when it is working.
  4. Less Radiation: Toroidal structure and winding technology reduce electromagnetic radiation.
  5. Low Temperature Rise: Even if it is overloaded at 120%, the temperature rise will be less than 70℃.

600VA Toroidal Transformer Specifications

ModelATO-T-C600VA
PhaseSingle phase
Power600VA (600W)
Primary Voltage240V AC (Optional: 110V, 120V, 220V, 230V, 240V)
Secondary Voltage12V AC (Optional: 12V, 24V, 48V, 110V, 220V, 2x6V, 2x12V, 2x15V, 2x24V, 2x30V, 2x35V, 2x40V, 2x50V, can be customized)
Secondary Current12.5A
No. of Inputs1 input
No. of Outputs1 output, 4-wire (4-wire 2 outputs are available)
Note: For the transformer with 2 outputs 4-wire, each output provides the same voltage and current level, the sum of 2 output power capacities is equal to the total capacity.
Frequency50Hz/60Hz
Winding MaterialCopper Wire
Coil StructureToroidal
Efficiency90%-96%
No-load Loss<3.77W
Input WireUL1672-18#Red
Output WireUL1015-16#Brown
Voltage StrengthDC2500V
Insulation Impedance≥500MΩ
Cooling MethodNatural air cooling
Temperature+40℃
CertificationCE, RoHS, ISO
Warranty12 months
External Diameter141mm
Height66mm
Pedestal140*140mm
Mounting Hole Distance130*130mm
Weight5.5kg
Package Included1*Toroidal transformer + 1*Accesorries sets (Nut, Shim, Metal disk, Rubber gasket, Pedestal, Screw)

Toroidal Transformer Accessories

toroidal transformer accessories

Toroidal Transformer Mounting Methods

toroidal transformer mounting method

Toroidal Transformer Internal Structure

toroidal transformer internal structure

Tips: How to distinguish the input and output of a toroidal transformer without lable?

The toroidal transformer is composed of input and output leads, so it is very important to correctly distinguish the input end from output end of toroidal transformer. If you fail to connect the input and output ends of toroidal transformer correctly, the transformer will be burnt down. What's more, the machine will be burnt down on a serious level. Therefore, it is necessary to correctly distinguish the input end from output end of transformer in use.

Generally, toroidal transformer manufacturers will attach labels on transformers in the production, so as to facilitate users for identification. So how to distinguish the input end from output ends of toroidal transformers without label? Here are two simple methods:

1. Instrument measurement

the multiple-use meter is used to measure the copper resistance value (single winding for secondary line) of transformers. There are two situations:

  • When measuring step-down transformer, the end with large winding resistance value is the input end, otherwise, it is the output end.
  • When measuring step-up transformer, the end with small winding resistance value is the input end, otherwise, it is the output end.

2. Appearance discrimination

The diameter of enamel-insulated wires (single winding for secondary line) is observed. Also, there are two situations:

  1. For a step-down transformer, the end with more winding coils and finer enamel-insulated wires is the input end, otherwise, it is the output end.
  2. For a step-up transformer, the end with less winding coils and thicker enamel-insulated wires is the input end, otherwise, it is the output end.

Compared with ordinary transformers, toroidal transformers have great advantages in efficiency, temperature rise, cost, anti-interference, and longevity. This video will showcase its function and benefits.

Product reviews
versatile, reliable and convenient choice
5
Fredric
Avatar
6/11/2024 11:41 PM
I've used the 600VA Toroidal Transformer to drive LED lighting setups in my home, providing consistent illumination with minimal hassle. Additionally, it's been instrumental in powering audio amplifier circuits for my DIY speaker projects, ensuring high-quality sound output without any fuss. Its compact size is a bonus, fitting seamlessly into project enclosures without hogging space. Overall, the 600VA Toroidal Transformer has earned its place as a reliable workhorse in my toolkit, simplifying power management and enhancing the performance of my projects.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Customized step up or step down toroidal transformers with 600VA capacity, 1-phase, a single 240V/50-60Hz primary winding, 12V/ 24V/ 2x50V AC secondary winding for selecting, manufactured, and tested in compliance with CE, RoHS, ISO standards.

Advantages of ATO Toroidal Transformer

  1. High Efficiency: Winding matches the core perfectly, which makes the transformer more efficient.
  2. Long Service Life: With high-quality materials and manufacturing technology, the transformer can be used for 30 years.
  3. Less Noise: The core is seamlessly rolled and the winding is set evenly over it, which makes the transformer quiet when it is working.
  4. Less Radiation: Toroidal structure and winding technology reduce electromagnetic radiation.
  5. Low Temperature Rise: Even if it is overloaded at 120%, the temperature rise will be less than 70℃.

600VA Toroidal Transformer Specifications

ModelATO-T-C600VA
PhaseSingle phase
Power600VA (600W)
Primary Voltage240V AC (Optional: 110V, 120V, 220V, 230V, 240V)
Secondary Voltage12V AC (Optional: 12V, 24V, 48V, 110V, 220V, 2x6V, 2x12V, 2x15V, 2x24V, 2x30V, 2x35V, 2x40V, 2x50V, can be customized)
Secondary Current12.5A
No. of Inputs1 input
No. of Outputs1 output, 4-wire (4-wire 2 outputs are available)
Note: For the transformer with 2 outputs 4-wire, each output provides the same voltage and current level, the sum of 2 output power capacities is equal to the total capacity.
Frequency50Hz/60Hz
Winding MaterialCopper Wire
Coil StructureToroidal
Efficiency90%-96%
No-load Loss<3.77W
Input WireUL1672-18#Red
Output WireUL1015-16#Brown
Voltage StrengthDC2500V
Insulation Impedance≥500MΩ
Cooling MethodNatural air cooling
Temperature+40℃
CertificationCE, RoHS, ISO
Warranty12 months
External Diameter141mm
Height66mm
Pedestal140*140mm
Mounting Hole Distance130*130mm
Weight5.5kg
Package Included1*Toroidal transformer + 1*Accesorries sets (Nut, Shim, Metal disk, Rubber gasket, Pedestal, Screw)

Toroidal Transformer Accessories

toroidal transformer accessories

Toroidal Transformer Mounting Methods

toroidal transformer mounting method

Toroidal Transformer Internal Structure

toroidal transformer internal structure

Tips: How to distinguish the input and output of a toroidal transformer without lable?

The toroidal transformer is composed of input and output leads, so it is very important to correctly distinguish the input end from output end of toroidal transformer. If you fail to connect the input and output ends of toroidal transformer correctly, the transformer will be burnt down. What's more, the machine will be burnt down on a serious level. Therefore, it is necessary to correctly distinguish the input end from output end of transformer in use.

Generally, toroidal transformer manufacturers will attach labels on transformers in the production, so as to facilitate users for identification. So how to distinguish the input end from output ends of toroidal transformers without label? Here are two simple methods:

1. Instrument measurement

the multiple-use meter is used to measure the copper resistance value (single winding for secondary line) of transformers. There are two situations:

  • When measuring step-down transformer, the end with large winding resistance value is the input end, otherwise, it is the output end.
  • When measuring step-up transformer, the end with small winding resistance value is the input end, otherwise, it is the output end.

2. Appearance discrimination

The diameter of enamel-insulated wires (single winding for secondary line) is observed. Also, there are two situations:

  1. For a step-down transformer, the end with more winding coils and finer enamel-insulated wires is the input end, otherwise, it is the output end.
  2. For a step-up transformer, the end with less winding coils and thicker enamel-insulated wires is the input end, otherwise, it is the output end.
Product reviews
versatile, reliable and convenient choice
5
Fredric
Avatar
6/11/2024 11:41 PM
I've used the 600VA Toroidal Transformer to drive LED lighting setups in my home, providing consistent illumination with minimal hassle. Additionally, it's been instrumental in powering audio amplifier circuits for my DIY speaker projects, ensuring high-quality sound output without any fuss. Its compact size is a bonus, fitting seamlessly into project enclosures without hogging space. Overall, the 600VA Toroidal Transformer has earned its place as a reliable workhorse in my toolkit, simplifying power management and enhancing the performance of my projects.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews