AC PMSM electric motor is mostly used for air cooler, laminator, outdoor auto control machine and monitor, etc. It is reversible and starts by capacitor.
Specification
| Model | ATO-60TYD-B60 | |||||
| Duty Type | S1 Continues | S2 (30 mins) | ||||
| Voltage (AC) | 24V | 110V | 220V-240V | 24V | 110V | 220V-240V |
| Power Frequency | 50/60 Hz | 50/60 Hz | ||||
| Output Speed | 60 rpm | |||||
| Output Torque | 7 Kgf·cm | 7 Kgf·cm | ||||
| Rated Speed | 1200 rpm | 1200 rpm | ||||
| Input Power | < 17W | < 25W | ||||
| Input Current | < 0.65A | < 0.15A | < 0.08A | < 1.5A | < 0.35A | < 0.2A |
| Rotation | CW/CCW (Reversible) | CW/CCW (Reversible) | ||||
| Operating Temperature | -15 ~ 40℃ | -15 ~ 40℃ | ||||
| Coil Temperature Rise | < 80K | < 80K | ||||
| Insulation Class | B | B | ||||
| Insulation Strength | AC 1500/ 50Hz/min | AC 1500/ 50Hz/min | ||||
| Recommended Capacitance | 47μF/ 63V | 2.2μF/ 250V | 0.56μF/ 450V | 67μF/ 63V | 3.0μF/ 250V | 0.8μF/ 450V |
Dimension (Unit: mm)

Detail

Tips: AC synchronous motor basics
- The speed of a synchronous motor is dependent only on the stator frequency.
- Below the base speed, the stator voltage is proportional to the stator frequency, that is, the higher the motor speed is, the higher the stator voltage and frequency of the motor are, and the current increases with the increase of the speed.
- Above the base speed, the stator voltage only rises to the rated voltage, the stator frequency rises and the rotor current decreases.
- The stator current is proportional to the load, and the rotor current increases with the increase of the load, but not in a proportional relationship, that is, when the stator current increases, the rotor current also increases.
- When the AC synchronous motor is directly connected to the grid, it must be dragged to the synchronous speed by other power before the stator can be connected to the grid. The reason is that when the motor does not rotate, there is no counter electromotive force. If the stator is connected to the grid at this time, it is equivalent to the stator short circuit, which will burn the motor.
Product reviews
Fast shipping and very quiet.
Vernon
4/14/2022 6:54 PM
Arrived very quickly and the 60 rpm AC synchronous motor was as advertised. It was very quiet. This was exactly what I needed to replace the one that was not operating. Worked perfect for ice maker.
Was this review helpful? (0/0)
Very satisfied.
Karlson
4/19/2022 3:27 AM
This was a perfect 60 rpm AC synchronous motor I needed. It was a great fit, speed and runs like a top. I love it. Great value for its quality and performance. Very satisfied.
Was this review helpful? (0/0)
60 rpm synchronous motor works as advertised
Keran
5/23/2022 6:55 PM
Works as advertised. I have ran the 60 synchronous motor continuously for 8 sessions between 16 and 26 hours with no issues. Definitely recommend!!
Was this review helpful? (0/0)
This synchronous motor works great.
Aaron
7/28/2022 1:18 AM
I used this synchronous motor to replace a failed one on an oscillating fan, it works great. Very easy to wire and mount. It is very quiet and so far it seem to be pretty durable. I will buy more if I need.
Was this review helpful? (0/0)
Worked as well as I expected
Beeyh
1/9/2023 12:38 AM
I bought this 60 rpm AC synchronous motor with a trial mentality, and it worked as well as I expected. Good easy to use, very quiet and works very well. I will be purchasing more.
Was this review helpful? (0/0)
Only registered users can write reviews