6 amp 2 pole Miniature Circuit Breaker

$65.79
Cost-effective double pole C6 miniature circuit breaker with 6 amp rated current, C curve trip characteristic, DIN rail mounting, meets IEC standard. This MCB breaker can safely be used in AC 50Hz, 230/400V with a 6 kA rated short-circuit breaking capacity, providing an electrical circuit from damage caused by overload or short circuits.
SKU: ATO-MCB-2P06
Free Shipping
Delivery date: 6-12 days

6 amp 2 pole mini circuit breaker provides overload and short circuit protection for conductors, DIN rail mounting, and safety in use. This MCB breaker has a 6kA rated short-circuit breaking capacity and can prevent potential hazards like fire or equipment damage.

Double Pole MCB Breaker Information

  • Rated Current: 6 amp
  • Rated Voltage: 230/400V AC, 50Hz
  • Number of poles: 2 poles
  • 6 kA rated short-circuit breaking capacity
  • Compliant with IEC standard
  • C curve trip characteristic
  • With overload protection and short circuit protection function

Technical Data

ModelATO-NB8-632PC06
Rated Current6A
Rated Voltage230/400V
Frequency50Hz
Number of Poles2P
Mechanical Life20000 Times
Electrical Life10000 Times
Rated Short-Circuit Breaking Capacity6000A
Operating Short-Circuit Breaking Capacity6000A
Rated Impulse Withstand Voltage (1.2/50)6kV
Dielectric Test Voltage2000V (50Hz, 1 min)
Heat & Humidity Resistance28 Cycles
Vibration ResistanceNo Obvious Vibration and Impact
Terminal BlockTerminal Block TypePillar Terminal Block
Min. Terminal Size Acceptability1mm2
Max. Terminal Size Acceptability25mm2
Standard Connection Torque2 N.m
Max. Tolerable Torque2.5 N.m
Wire Insertion Depth13mm
Reference Temperature30℃
Operating Temperature-35℃~+70℃
Storage Temperature35℃~+85℃
Applicable Altitude2000m
Tripping ModeThermal Magnetic Trip
Electromagnetic Tripping TypeType C (5In-10In)
Shell Flame Retardant GradeV0
Wire Entry MethodBoth Upper and Lower
Installation MethodTH35-7.5 Standard Rail
Protection LevelDirect InstallationIP20B
Installed in the Distribution BoxIP40B


Double Pole MCB Breaker Dimensions (Unit: mm)

6 amp 2 pole Miniature Circuit Breaker Dimensions

Details

2 pole Miniature Circuit Breaker Details

Tips: Working conditions of miniature circuit breakers

  • The upper limit of ambient temperature should not exceed +40℃, the lower limit should not be lower than -5℃, and the average temperature of 24h should not exceed +35℃.
  • The altitude of the installation site does not exceed 2000m.
  • The relative humidity of the atmosphere does not exceed 50% when the ambient air temperature is +40℃. Higher relative humidity can be allowed at a lower temperature, for example, up to 90% at +20℃. Appropriate measures should be taken for condensation.
  • The external magnetic field of the installation site should not exceed 5 times the geomagnetic field in any direction.
  • The miniature circuit breaker is generally installed vertically, with a tolerance of 2° in any direction.
  • There should be no significant impact and vibration at the installation site.

Types of Circuit Breakers

In this video, we'll take a closer look at the meaning behind these abbreviations and explain the types of circuit breakers they represent. By understanding the different types of circuit breakers on the market, you can make an informed decision and choose the right type for your specific requirements, thereby enhancing the protection of your electrical infrastructure.

Isolator vs Circuit Breaker

Although isolators and circuit breakers have similar functions in a circuit, they are two separate entities. This video explains you the difference between the two devices in terms of working, features, operation, affordability, etc. You can choose between them based on your specific requirements.

Product reviews
Praise for 6 amp miniature circuit breaker
5
Oshantshany
Avatar
12/15/2021 6:51 PM
Let me start with the quality of the 6-amp miniature circuit breaker.
The product is generally good and the packaging is tight.
Let’s talk about business services: very good.
Last review express: delivery is fast.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

6 amp 2 pole mini circuit breaker provides overload and short circuit protection for conductors, DIN rail mounting, and safety in use. This MCB breaker has a 6kA rated short-circuit breaking capacity and can prevent potential hazards like fire or equipment damage.

Double Pole MCB Breaker Information

  • Rated Current: 6 amp
  • Rated Voltage: 230/400V AC, 50Hz
  • Number of poles: 2 poles
  • 6 kA rated short-circuit breaking capacity
  • Compliant with IEC standard
  • C curve trip characteristic
  • With overload protection and short circuit protection function

Technical Data

ModelATO-NB8-632PC06
Rated Current6A
Rated Voltage230/400V
Frequency50Hz
Number of Poles2P
Mechanical Life20000 Times
Electrical Life10000 Times
Rated Short-Circuit Breaking Capacity6000A
Operating Short-Circuit Breaking Capacity6000A
Rated Impulse Withstand Voltage (1.2/50)6kV
Dielectric Test Voltage2000V (50Hz, 1 min)
Heat & Humidity Resistance28 Cycles
Vibration ResistanceNo Obvious Vibration and Impact
Terminal BlockTerminal Block TypePillar Terminal Block
Min. Terminal Size Acceptability1mm2
Max. Terminal Size Acceptability25mm2
Standard Connection Torque2 N.m
Max. Tolerable Torque2.5 N.m
Wire Insertion Depth13mm
Reference Temperature30℃
Operating Temperature-35℃~+70℃
Storage Temperature35℃~+85℃
Applicable Altitude2000m
Tripping ModeThermal Magnetic Trip
Electromagnetic Tripping TypeType C (5In-10In)
Shell Flame Retardant GradeV0
Wire Entry MethodBoth Upper and Lower
Installation MethodTH35-7.5 Standard Rail
Protection LevelDirect InstallationIP20B
Installed in the Distribution BoxIP40B


Double Pole MCB Breaker Dimensions (Unit: mm)

6 amp 2 pole Miniature Circuit Breaker Dimensions

Details

2 pole Miniature Circuit Breaker Details

Tips: Working conditions of miniature circuit breakers

  • The upper limit of ambient temperature should not exceed +40℃, the lower limit should not be lower than -5℃, and the average temperature of 24h should not exceed +35℃.
  • The altitude of the installation site does not exceed 2000m.
  • The relative humidity of the atmosphere does not exceed 50% when the ambient air temperature is +40℃. Higher relative humidity can be allowed at a lower temperature, for example, up to 90% at +20℃. Appropriate measures should be taken for condensation.
  • The external magnetic field of the installation site should not exceed 5 times the geomagnetic field in any direction.
  • The miniature circuit breaker is generally installed vertically, with a tolerance of 2° in any direction.
  • There should be no significant impact and vibration at the installation site.
Product reviews
Praise for 6 amp miniature circuit breaker
5
Oshantshany
Avatar
12/15/2021 6:51 PM
Let me start with the quality of the 6-amp miniature circuit breaker.
The product is generally good and the packaging is tight.
Let’s talk about business services: very good.
Last review express: delivery is fast.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews
Customers who bought this item also bought

3 amp 2 pole Miniature Circuit Breaker

ATO-MCB-2P03
$69.69
3 amp 2 pole 6kA miniature circuit breaker (MCB) complies with IEC standard, with C trip characteristic to meet protecting requirements. This mini circuit breaker has a compact structure, DIN rail installation, reliable performance, good interrupt capacity, and safety in use.