Let me start with the quality of the 6-amp miniature circuit breaker.
The product is generally good and the packaging is tight.
Let’s talk about business services: very good.
Last review express: delivery is fast.
6 amp 2 pole mini circuit breaker provides overload and short circuit protection for conductors, DIN rail mounting, and safety in use. This MCB breaker has a 6kA rated short-circuit breaking capacity and can prevent potential hazards like fire or equipment damage.
Double Pole MCB Breaker Information
- Rated Current: 6 amp
- Rated Voltage: 230/400V AC, 50Hz
- Number of poles: 2 poles
- 6 kA rated short-circuit breaking capacity
- Compliant with IEC standard
- C curve trip characteristic
- With overload protection and short circuit protection function
Technical Data
| Model | ATO-NB8-632PC06 | |
| Rated Current | 6A | |
| Rated Voltage | 230/400V | |
| Frequency | 50Hz | |
| Number of Poles | 2P | |
| Mechanical Life | 20000 Times | |
| Electrical Life | 10000 Times | |
| Rated Short-Circuit Breaking Capacity | 6000A | |
| Operating Short-Circuit Breaking Capacity | 6000A | |
| Rated Impulse Withstand Voltage (1.2/50) | 6kV | |
| Dielectric Test Voltage | 2000V (50Hz, 1 min) | |
| Heat & Humidity Resistance | 28 Cycles | |
| Vibration Resistance | No Obvious Vibration and Impact | |
| Terminal Block | Terminal Block Type | Pillar Terminal Block |
| Min. Terminal Size Acceptability | 1mm2 | |
| Max. Terminal Size Acceptability | 25mm2 | |
| Standard Connection Torque | 2 N.m | |
| Max. Tolerable Torque | 2.5 N.m | |
| Wire Insertion Depth | 13mm | |
| Reference Temperature | 30℃ | |
| Operating Temperature | -35℃~+70℃ | |
| Storage Temperature | 35℃~+85℃ | |
| Applicable Altitude | 2000m | |
| Tripping Mode | Thermal Magnetic Trip | |
| Electromagnetic Tripping Type | Type C (5In-10In) | |
| Shell Flame Retardant Grade | V0 | |
| Wire Entry Method | Both Upper and Lower | |
| Installation Method | TH35-7.5 Standard Rail | |
| Protection Level | Direct Installation | IP20B |
| Installed in the Distribution Box | IP40B | |
Double Pole MCB Breaker Dimensions (Unit: mm)

Details

Tips: Working conditions of miniature circuit breakers
- The upper limit of ambient temperature should not exceed +40℃, the lower limit should not be lower than -5℃, and the average temperature of 24h should not exceed +35℃.
- The altitude of the installation site does not exceed 2000m.
- The relative humidity of the atmosphere does not exceed 50% when the ambient air temperature is +40℃. Higher relative humidity can be allowed at a lower temperature, for example, up to 90% at +20℃. Appropriate measures should be taken for condensation.
- The external magnetic field of the installation site should not exceed 5 times the geomagnetic field in any direction.
- The miniature circuit breaker is generally installed vertically, with a tolerance of 2° in any direction.
- There should be no significant impact and vibration at the installation site.