Double pole 40 amp miniature circuit breaker (MCB) offers essential overload and short-circuit protection. This micro circuit breaker is commonly used for branch circuit protection in residential electrical installations, providing safety for air conditioners, electric water heaters, or kitchen appliances.
Double Pole MCB Breaker Information
- Rated Current: 40 amp
- Rated Voltage: 230/400V AC, 50Hz
- Number of poles: 2 poles
- 6 kA rated short-circuit breaking capacity
- Compliant with IEC standard
- C curve trip characteristic
- With overload protection and short circuit protection function
Technical Data
| Model | ATO-NB8-632PC40 | |
| Rated Current | 40A | |
| Rated Voltage | 230/400V | |
| Frequency | 50Hz | |
| Number of Poles | 2P | |
| Mechanical Life | 20000 Times | |
| Electrical Life | 10000 Times | |
| Rated Short-Circuit Breaking Capacity | 6000A | |
| Operating Short-Circuit Breaking Capacity | 6000A | |
| Rated Impulse Withstand Voltage (1.2/50) | 6kV | |
| Dielectric Test Voltage | 2000V (50Hz, 1 min) | |
| Heat & Humidity Resistance | 28 Cycles | |
| Vibration Resistance | No Obvious Vibration and Impact | |
| Terminal Block | Terminal Block Type | Pillar Terminal Block |
| Min. Terminal Size Acceptability | 1mm2 | |
| Max. Terminal Size Acceptability | 25mm2 | |
| Standard Connection Torque | 2 N.m | |
| Max. Tolerable Torque | 2.5 N.m | |
| Wire Insertion Depth | 13mm | |
| Reference Temperature | 30℃ | |
| Operating Temperature | -35℃~+70℃ | |
| Storage Temperature | 35℃~+85℃ | |
| Applicable Altitude | 2000m | |
| Tripping Mode | Thermal Magnetic Trip | |
| Electromagnetic Tripping Type | Type C (5In-10In) | |
| Shell Flame Retardant Grade | V0 | |
| Wire Entry Method | Both Upper and Lower | |
| Installation Method | TH35-7.5 Standard Rail | |
| Protection Level | Direct Installation | IP20B |
| Installed in the Distribution Box | IP40B | |
Double Pole MCB Breaker Dimensions (Unit: mm)

Details

Tips: Troubleshooting of miniature circuit breaker
- The inlet and outlet connections of the mini circuit breaker are directly tightened with bolts. In situations where the load changes greatly, they are not checked and tightened in time, resulting in poor local contact.
- It is used on occasions with high inrush current, such as computer and classroom control switches. And there are often phenomena such as closing and tripping and mechanism failure.
- The contacts of individual miniature circuit breakers are oxidized, causing contact failure. In the home power distribution installation, to meet the requirements of large variable loads, the rated capacity of the main power switch should be a larger miniature circuit breaker, and the leakage protection device should be matched. The miniature circuit breaker of the output branch should be selected according to the actual calculated load capacity.
Product reviews
Good value for what it costs.
Richard J.
5/23/2022 2:35 AM
I used this 2 pole miniature circuit breaker for a generator to replace an older breaker. The DIN mounting system is excellent. Very prompt delivery after ordering. I am happy with this purchase and definitely buy again.
Was this review helpful? (0/0)
Only registered users can write reviews