Cheap 4 hp vertical centrifugal pump adopts a single-stage stainless steel impeller, which can be operated in series or in parallel for a large flow/high head water supply. High quality vertical centrifugal pump has a maximum flow of 16.3m3/h (72 gpm), a maximum lift of 33m (108ft), 50mm (2 inch) diameter, optional input voltage of 3 phase AC 230V/240V/400V/415V/480V and 50Hz/60Hz input frequency.
SKU: ATO-VCP-3000W
*
*
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Delivery date: 6-12 days

3 phase 4 hp vertical centrifugal pump is the single-stage pump. It has 16.3m3/h maximum flow, 30m minimum head, 33m maximum head, and 0°, 90°,180° installation angle of outlet.

Features:

  • The centrifugal pump has a vertical structure, and its inlet and outlet have the same diameter. The inlet and outlet are on the same centerline so that they can be installed in the pipeline like a valve. If a protective cover is added, it can be used in the open air.
  • Easy to install and maintain. There is no need to dismantle the piping system, just remove the connecting flat nut of the vertical pump. All rotor parts can then be removed.
  • The vertical pump can be installed vertically or horizontally according to the requirements of the piping system.
  • Vertical centrifugal pumps can be run in series or in parallel according to the requirements of flow and head.

Specification

  • Model: ATO-VCP-50-160
  • Power: 4 hp (3kW)
  • Number of stages: Single stage
  • Input voltage: AC 220V~480V
  • Input frequency: 50Hz/60Hz
  • Inlet diameter: 50mm (2 inch)
  • Outlet diameter: 50mm (2 inch)
  • Flow (min. flow to max. flow): 8.8m3/h (39 gpm), 12.5m3/h (55 gpm), 16.3m3/h (72 gpm)
  • Head (max. head to min. head): 33m (108ft), 32m (105ft), 30m (98ft)
  • Efficiency: 45%, 52%, 51%
  • Installation mode: Vertical type or horizontal type
  • Nominal diameter of impeller: 160mm
  • Size: 320*300*540mm
  • Weight: 80kg

Vertical centrifugal pump dimension (unit: mm):

Vertical centrifugal pump dimensional drawing

Boundary dimensionLBHC1*B1
320300540120*170
Installation dimensionAC2*B24-Φd1
10080*1304-Φ18
Flange dimensionDD1n-φd
φ165φ1254-φ18

Details

Vertical Centrifugal Pump Details

Tips: What is the HPSH of the centrifugal pump?

At a certain temperature, when the pressure is reduced below the vaporized pressure of the temperature, the liquid will generate bubbles. Such a bubble generating condition is called cavitation. The bubbles generated in cavitation have the size minimized gradually and then finally break when they flow to the high-pressure site. This phenomenon in which the bubble disappears in the liquid due to the pressure rise is called cavitation collapse. In the operation process of the pump, if the absolute pressure of the pumped liquid is lowered to the liquid vaporization pressure at the current temperature in some areas of the overflow part due to certain factors, the liquid starts to vaporize there, generating a large amount of vapor and forming bubbles. When the liquid containing a large number of bubbles forwards and passes through the high-pressure zone, the high-pressure liquid around the bubble sharply shrinks the bubbles and breaks them. At the same time that the bubble condenses and ruptures, the liquid particles fill the cavity at a high speed. At this moment, a strong impact is generated, and the metal surface is struck at a high impact frequency. The impact force can reach several hundred to several thousand barometric pressures, and the impact frequency can reach tens of thousands of times per second. As a result, the wall thickness will be broken down if it is serious. The process of creating bubbles in the pump and bubble breakage causing damage to the overflow part is the cavitation process in the pump. In addition to the destructive effect on the overcurrent components, noise and vibration will be generated as well, and the performance of the pump will be reduced accordingly. In severe cases, the liquid in the pump will be interrupted and the pump can no longer work normally.

NPSH (net positive suction head): To prevent cavitation, the sum of the static head and the dynamic head at the inlet of the centrifugal pump must be greater than the minimum allowable value of the saturated vapor head at the delivery temperature.

Phase3 phase
Input voltageAC 220V, 230V, 240V, 380V, 400V, 415V, 440V, 460V, 480V
Input frequency50Hz, 60Hz
Installation angle of outlet0°, 90° and 180°
Pump typeBooster pump
Number of stagesSingle stage
Motor typeY/ Y2 series motor
Motor speed2900rpm
Impeller material304/ 316 stainless steel
Seal material304 stainless steel, tungsten carbide, fluorine rubber
Inlet max. pressure1MPa (145 psi)
(NPSH)r2.3m
UsageWater, or liquids compatible with pump component materials.
1. The volume of solid particles should be less than 0.1% in unit volume, and the granularity should be less than 0.2mm.
2. The temperature should be lower than 60℃.
EnvironmentTemperature: <40℃, humidity: <95%, altitude<1000m
Warranty12 months

Different types of centrifugal pumps

This video explains different types of centrifugal pumps that can be selected according to one's own needs.

Principles and functionality explained

This video tells us what a centrifugal pump is and its working principle, and you will have a general understanding of it.

Components of centrifugal pumps

This video is an explanation of the components of a centrifugal pump, and we can learn the basic knowledge of the eight components of a centrifugal pump from it.

Proposition 65 Warning

*WARNING: This product can expose you to chemicals, including lead, which is known to the State of California to cause birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.

Product reviews
The 4hp vertical centrifugal pump exceeded my expectations
5
Rowan
Avatar
8/20/2025 8:18 PM
When I first installed the 4 hp vertical centrifugal pump, I wasn't sure how it would handle my system's demands. To my surprise, it exceeded expectations. The flow rate was steady, and the vertical design saved me space. What impressed me most was how simple it was to maintain; the rotor came out easily without disturbing the pipes. It's been running continuously, and I haven't had a single issue so far.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

3 phase 4 hp vertical centrifugal pump is the single-stage pump. It has 16.3m3/h maximum flow, 30m minimum head, 33m maximum head, and 0°, 90°,180° installation angle of outlet.

Features:

  • The centrifugal pump has a vertical structure, and its inlet and outlet have the same diameter. The inlet and outlet are on the same centerline so that they can be installed in the pipeline like a valve. If a protective cover is added, it can be used in the open air.
  • Easy to install and maintain. There is no need to dismantle the piping system, just remove the connecting flat nut of the vertical pump. All rotor parts can then be removed.
  • The vertical pump can be installed vertically or horizontally according to the requirements of the piping system.
  • Vertical centrifugal pumps can be run in series or in parallel according to the requirements of flow and head.

Specification

  • Model: ATO-VCP-50-160
  • Power: 4 hp (3kW)
  • Number of stages: Single stage
  • Input voltage: AC 220V~480V
  • Input frequency: 50Hz/60Hz
  • Inlet diameter: 50mm (2 inch)
  • Outlet diameter: 50mm (2 inch)
  • Flow (min. flow to max. flow): 8.8m3/h (39 gpm), 12.5m3/h (55 gpm), 16.3m3/h (72 gpm)
  • Head (max. head to min. head): 33m (108ft), 32m (105ft), 30m (98ft)
  • Efficiency: 45%, 52%, 51%
  • Installation mode: Vertical type or horizontal type
  • Nominal diameter of impeller: 160mm
  • Size: 320*300*540mm
  • Weight: 80kg

Vertical centrifugal pump dimension (unit: mm):

Vertical centrifugal pump dimensional drawing

Boundary dimensionLBHC1*B1
320300540120*170
Installation dimensionAC2*B24-Φd1
10080*1304-Φ18
Flange dimensionDD1n-φd
φ165φ1254-φ18

Details

Vertical Centrifugal Pump Details

Tips: What is the HPSH of the centrifugal pump?

At a certain temperature, when the pressure is reduced below the vaporized pressure of the temperature, the liquid will generate bubbles. Such a bubble generating condition is called cavitation. The bubbles generated in cavitation have the size minimized gradually and then finally break when they flow to the high-pressure site. This phenomenon in which the bubble disappears in the liquid due to the pressure rise is called cavitation collapse. In the operation process of the pump, if the absolute pressure of the pumped liquid is lowered to the liquid vaporization pressure at the current temperature in some areas of the overflow part due to certain factors, the liquid starts to vaporize there, generating a large amount of vapor and forming bubbles. When the liquid containing a large number of bubbles forwards and passes through the high-pressure zone, the high-pressure liquid around the bubble sharply shrinks the bubbles and breaks them. At the same time that the bubble condenses and ruptures, the liquid particles fill the cavity at a high speed. At this moment, a strong impact is generated, and the metal surface is struck at a high impact frequency. The impact force can reach several hundred to several thousand barometric pressures, and the impact frequency can reach tens of thousands of times per second. As a result, the wall thickness will be broken down if it is serious. The process of creating bubbles in the pump and bubble breakage causing damage to the overflow part is the cavitation process in the pump. In addition to the destructive effect on the overcurrent components, noise and vibration will be generated as well, and the performance of the pump will be reduced accordingly. In severe cases, the liquid in the pump will be interrupted and the pump can no longer work normally.

NPSH (net positive suction head): To prevent cavitation, the sum of the static head and the dynamic head at the inlet of the centrifugal pump must be greater than the minimum allowable value of the saturated vapor head at the delivery temperature.

Product reviews
The 4hp vertical centrifugal pump exceeded my expectations
5
Rowan
Avatar
8/20/2025 8:18 PM
When I first installed the 4 hp vertical centrifugal pump, I wasn't sure how it would handle my system's demands. To my surprise, it exceeded expectations. The flow rate was steady, and the vertical design saved me space. What impressed me most was how simple it was to maintain; the rotor came out easily without disturbing the pipes. It's been running continuously, and I haven't had a single issue so far.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews