3V DC Signal Relay, DPDT, 2A

$16.36
Miniature low signal relay at affordable price, optional coil nominal power 200mW/150 mW, coil voltage 3V DC, contact form DPDT, max. switching current 2A, rated load 1A 125VAC/2A 30VDC.
SKU: ATO-SR-W32DC3V
*
This product has a minimum quantity of 10
Free Shipping
Delivery date: 6-12 days

Buy mini 3V DC signal relay online, contact form DPDT (2C), widely applications in automatic control system.

Features

  • 2A contact switching capability.
  • High sensitive type, coil power is 150mW/200mW.
  • Standard DIP construction terminal.
  • Ultra – small type, gold – plated contacts.
  • Suit for complete machine wave soldering and integral cleaning process.
  • Main applications: Electric power protection, automation, communication.

Specification

ModelATO-SR-FH32DC3V
TypeStandard TypeSensitive Type
Coil Parameters (23℃)Nominal VoltageDC 3V
Nominal Power200mW150mW
Pick-up Voltage≤2.25VDC≤2.25VDC
Drop-out Voltage≥0.15VDC≥0.15VDC
Rated Current66.7mA50mA
Coil Resistance45Ω60Ω
Max VoltageDC 3.9VDC 3.9V
Contact ParametersContact FormDPDT (2C)
Contact Resistance (Initial)≤100mΩ (6VDC 1A)
Contact MaterialAgNi + Gold Plating
Rated ValueRated Load (Resistance Load)1A 125VAC
2A 30VDC
Max. Switching Voltage250VAC30VDC
Max. Switching Current2A
Max. Switching Capacity125VA/60W
Min. Allowing Load10mV 10μA
Electrical PerformanceInsulation Resistance (Initial)1000mΩ (500VDC)
Dielectric Strength (Initial)Between Open Contacts750VAC, 1 min
Between Coil & Contacts1500VAC, 1 min
Operate Time≤5ms
Release Time≤5ms
Mechanical PerformanceShock ResistanceFunctional98m/s2(10g)
Destructive980m/s2(100g)
Vibration Resistance10Hz ~ 55Hz 1.5mm DA
EnduranceMechanical1 x 107ops
Electrical1A 125VAC 1 x 105ops (ON/OFF=1s/9s)
2A 30VDC 1 x 105ops (ON/OFF=1s/9s)
Operate ConditionAmbient Temperature-40℃ ~ 85℃
Humidity5% to 90%
TerminationPCB (DIP Encapsulation)
Unit Weight5g
ConstructionPlastic Sealed

Note: In order to maintain the initial performance parameters of the signal relay, please be careful not to drop it.

Dimension

Units: mm

Dimensions of Low Signal Relay

Performance curves

Performance Curves of Low Signal Relay

Tips: Working principle of signal relay

Generally, the signal relay is composed of iron core, coil, armature, contact reed. As long as a certain voltage is applied to both ends of the coil, a certain current will flow through it, resulting in electromagnetic effect. Under the action of electromagnetic force, the armature will overcome the tension of the return spring and attract to the iron core, thus driving the moving contact of the armature and the static contact (normally open contact) to attract. When the coil is powered off, the electromagnetic suction will also disappear, and the armature will return to its original position in the spring reactive force, making the moving contact and the original static contact (normally closed contact) release. In this way, it achieves the purpose of conducting and cutting in the circuit.

In this video we will try to clear the confusion many people have between relays and contactors by showing you how to tell the difference based on five criteria: Definition, Capacity, Structure, Contacts and Applications.

Product reviews
Exactly as described.
5
Karlson
Avatar
6/28/2022 1:07 AM
This 3V DC signal relay is perfect fit did exactly what it supposed to do. Easy to install and works perfectly. I have been running it for about 2 months.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Buy mini 3V DC signal relay online, contact form DPDT (2C), widely applications in automatic control system.

Features

  • 2A contact switching capability.
  • High sensitive type, coil power is 150mW/200mW.
  • Standard DIP construction terminal.
  • Ultra – small type, gold – plated contacts.
  • Suit for complete machine wave soldering and integral cleaning process.
  • Main applications: Electric power protection, automation, communication.

Specification

ModelATO-SR-FH32DC3V
TypeStandard TypeSensitive Type
Coil Parameters (23℃)Nominal VoltageDC 3V
Nominal Power200mW150mW
Pick-up Voltage≤2.25VDC≤2.25VDC
Drop-out Voltage≥0.15VDC≥0.15VDC
Rated Current66.7mA50mA
Coil Resistance45Ω60Ω
Max VoltageDC 3.9VDC 3.9V
Contact ParametersContact FormDPDT (2C)
Contact Resistance (Initial)≤100mΩ (6VDC 1A)
Contact MaterialAgNi + Gold Plating
Rated ValueRated Load (Resistance Load)1A 125VAC
2A 30VDC
Max. Switching Voltage250VAC30VDC
Max. Switching Current2A
Max. Switching Capacity125VA/60W
Min. Allowing Load10mV 10μA
Electrical PerformanceInsulation Resistance (Initial)1000mΩ (500VDC)
Dielectric Strength (Initial)Between Open Contacts750VAC, 1 min
Between Coil & Contacts1500VAC, 1 min
Operate Time≤5ms
Release Time≤5ms
Mechanical PerformanceShock ResistanceFunctional98m/s2(10g)
Destructive980m/s2(100g)
Vibration Resistance10Hz ~ 55Hz 1.5mm DA
EnduranceMechanical1 x 107ops
Electrical1A 125VAC 1 x 105ops (ON/OFF=1s/9s)
2A 30VDC 1 x 105ops (ON/OFF=1s/9s)
Operate ConditionAmbient Temperature-40℃ ~ 85℃
Humidity5% to 90%
TerminationPCB (DIP Encapsulation)
Unit Weight5g
ConstructionPlastic Sealed

Note: In order to maintain the initial performance parameters of the signal relay, please be careful not to drop it.

Dimension

Units: mm

Dimensions of Low Signal Relay

Performance curves

Performance Curves of Low Signal Relay

Tips: Working principle of signal relay

Generally, the signal relay is composed of iron core, coil, armature, contact reed. As long as a certain voltage is applied to both ends of the coil, a certain current will flow through it, resulting in electromagnetic effect. Under the action of electromagnetic force, the armature will overcome the tension of the return spring and attract to the iron core, thus driving the moving contact of the armature and the static contact (normally open contact) to attract. When the coil is powered off, the electromagnetic suction will also disappear, and the armature will return to its original position in the spring reactive force, making the moving contact and the original static contact (normally closed contact) release. In this way, it achieves the purpose of conducting and cutting in the circuit.

Product reviews
Exactly as described.
5
Karlson
Avatar
6/28/2022 1:07 AM
This 3V DC signal relay is perfect fit did exactly what it supposed to do. Easy to install and works perfectly. I have been running it for about 2 months.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews