30A Automotive Starter Relay, 12V/24V DC

$55.49
Low cost auto starter relay for sale, with 30A/40A contact current, available in contact form of 1Z (1C) or 1H (1A), coil rated voltage of 12V DC or 24V DC, 4 pin or 5 pin installation. This automotive starter relay is an electrical component in a car's starting system, acting as an intermediary between the ignition switch and the starter motor.
SKU: ATO-ASR-30
*
*
*
*
Free Shipping
Delivery date: 6-12 days

ATO automotive starter relay serves as a critical electrical switch that manages the substantial current required to engage the starter motor and initiate the engine's ignition process. Their role is pivotal in safeguarding the vehicle's ignition switch from excessive wear and tear by efficiently managing the flow of high currents necessary for starting the engine.

Specification

ModelATO-JD1914-12/24VDC
Coil ParameterRated Coil Voltage12V DC24V DC
Rated Current150mA75mA
Coil Resistance (Ω±10%)80Ω320Ω
Operate Voltage (Max.)6~8V DC12~16V DC
Release Voltage (Min.)0.6~3.6V DC1.2~7.2V DC
Applicable Voltage (Max.)15.6V DC31.2V DC
Operation ConditionInsulation Resistance100MΩ Min. (at 500V DC)
Dielectric StrengthBetween Contacts500V AC (for one minute/sec)
Between Coil and Contacts750V AC (for one minute/sec)
Shock ResistanceOperating Extremes10g
Damage Limits20g
Vibration Resistance10~55Hz 1.5mm
Release Time7ms
Operate Time5ms
Ambient Temperature-30℃~+80℃
Relative Humidity40~85%
Weight35g
Safety StandardCCEE Certification
Contact ParameterContact Form1Z (1C)/ 1H (1A)
Contact MaterialAgSnO12
Contact Rating (Resistance)NO: 40A 14V DC
Max. Switching Voltage75V DC
Max. Switching Current30A/40A
Max. Switching Power560W
Contact Resistance100mΩ Max. at 6V DC 1A
Electrical Life100000 Operations (at 30 Operations/Minute)
Mechanical Life10000000 Operations (at 30 Operations/Minute)


Dimension (Unit: mm)

30A/40A car starter relay dimension

Tips: Can a general-purpose relay be used to replace the car starter relay?

It is not recommended to use a general-purpose relay to replace the auto starter relay. The starter relay is specially designed to start the motor and can withstand high current and voltage. General-purpose relays may not be able to handle the peak value of the starting current, which can easily cause the relay to overheat or be damaged. In addition, the starter relay usually has special wiring and control requirements to ensure safe and reliable operation. Using an unsuitable relay may cause the starting circuit to malfunction, affect the normal operation of the equipment, and even cause safety hazards. Therefore, it is recommended to always use the original starter relay that matches the equipment to ensure the performance and safety of the equipment.

In this video we will try to clear the confusion many people have between relays and contactors by showing you how to tell the difference based on five criteria: Definition, Capacity, Structure, Contacts and Applications.

Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

ATO automotive starter relay serves as a critical electrical switch that manages the substantial current required to engage the starter motor and initiate the engine's ignition process. Their role is pivotal in safeguarding the vehicle's ignition switch from excessive wear and tear by efficiently managing the flow of high currents necessary for starting the engine.

Specification

ModelATO-JD1914-12/24VDC
Coil ParameterRated Coil Voltage12V DC24V DC
Rated Current150mA75mA
Coil Resistance (Ω±10%)80Ω320Ω
Operate Voltage (Max.)6~8V DC12~16V DC
Release Voltage (Min.)0.6~3.6V DC1.2~7.2V DC
Applicable Voltage (Max.)15.6V DC31.2V DC
Operation ConditionInsulation Resistance100MΩ Min. (at 500V DC)
Dielectric StrengthBetween Contacts500V AC (for one minute/sec)
Between Coil and Contacts750V AC (for one minute/sec)
Shock ResistanceOperating Extremes10g
Damage Limits20g
Vibration Resistance10~55Hz 1.5mm
Release Time7ms
Operate Time5ms
Ambient Temperature-30℃~+80℃
Relative Humidity40~85%
Weight35g
Safety StandardCCEE Certification
Contact ParameterContact Form1Z (1C)/ 1H (1A)
Contact MaterialAgSnO12
Contact Rating (Resistance)NO: 40A 14V DC
Max. Switching Voltage75V DC
Max. Switching Current30A/40A
Max. Switching Power560W
Contact Resistance100mΩ Max. at 6V DC 1A
Electrical Life100000 Operations (at 30 Operations/Minute)
Mechanical Life10000000 Operations (at 30 Operations/Minute)


Dimension (Unit: mm)

30A/40A car starter relay dimension

Tips: Can a general-purpose relay be used to replace the car starter relay?

It is not recommended to use a general-purpose relay to replace the auto starter relay. The starter relay is specially designed to start the motor and can withstand high current and voltage. General-purpose relays may not be able to handle the peak value of the starting current, which can easily cause the relay to overheat or be damaged. In addition, the starter relay usually has special wiring and control requirements to ensure safe and reliable operation. Using an unsuitable relay may cause the starting circuit to malfunction, affect the normal operation of the equipment, and even cause safety hazards. Therefore, it is recommended to always use the original starter relay that matches the equipment to ensure the performance and safety of the equipment.

Only registered users can write reviews