300 kVA Isolation Transformer, 3 phase, 480V to 400V

$30,086.16
300 kVA isolation transformer is a 3 phase unit with a primary voltage of 480V and secondary voltage of 400V, it's a safe isolating transformer not only provides an increased level of protection against electric shock, but also used to step down voltage of equipment.
SKU: ATO-T-SG300KVA
*
*
*
*
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Delivery date: 10-16 days

Three phase 300 kVA isolation transformer offers consistent, smooth voltage transformation at 480V AC input, 480V to 400V version or 400V to 480V is available, and other voltages can be customized.

Generally, isolation transformers with power above 150KVA will be equipped with an alarm, which is used to detect the temperature of the transformer. When the temperature of the transformer rises to 150 degrees, the alarm will be triggered. At this time, the transformer needs to be manually suspended or stopped. Wait until the transformer temperature returns to normal, then continue to use.

300 kVA Isolation Transformer Specifications

BasicsModelATO-SG300KVA
Phase3 phase
Capacity300 kVA
Weight of Aluminium Wire TransformerOpen type: 740kg
Protected type: 890kg
Weight of Copper Wire TransformerOpen type: 930kg
Protected type: 1005kg
Technical ParametersPrimary Voltage480V (Optional: 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Secondary Voltage400V (Optional: 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Frequency50Hz / 60 Hz
Winding MaterialAluminium/Copper wire (Optional)
Work Efficiency≥95%
Insulation Resistance≥50 MΩ
Electrical Strength3000V AC/1 min
Noise<35-65dB (1 meter)
Insulation GradeH level
Wiring ModeDyn11
Cooling ModeDry type air cooling
Overload CapacityAllow more than 1.2 times rated load to work for up to 4 hours
Enclosure Protection GradeIP 22
CertificateCE, ISO
Warranty12 months
Working EnvironmentTemperature-15℃~+40℃
Humidity≤90%RH, without condensation
Altitude<1000m, non corrosive gas and conductive dust

Note:
Transformer can only convert voltage and CANNOT convert frequency.
Transformer CANNOT convert single phase voltage to 3 phase voltage.
Input/output voltage, power rating and whether with shell of all transformers, can be customized according to clients' requirements.

3 Phase Isolation Transformer Schematic Diagram

ATO isolation transformers schematic diagram

3 Phase Isolation Transformer Details

High capacity isolation transformer details

300 kVA Isolation Transformer Installation Dimension

150kVA 800kVA isolation transformer dimension

Aluminium Wire Transformer SizeCopper Wire Transformer Size
Open type: a*b*c=1060**450*955mmOpen type: a*b*c=990**410*855mm
Mouting size: d*e=600*400mmMouting size: d*e=600*400mm
Protected type: A*B*C=1300*750*1600mmProtected type: A*B*C=1300*750*1600mm

Tips: Using isolation transformer to reduce the zero voltage of UPS

For medium and small power UPS, generally, an isolation transformer is installed at its output part; for a three-in to three-out high-power UPS, the transformer is usually at its bypass input. This method can eliminate the problem that zero voltage is low before the UPS powering on while zero voltage rises after UPS turning on. The UPS power system makes no negative impact on the power grid and load through this method.

Product reviews
300kVA isolation transformer can be customized
5
Kacey
Avatar
3/24/2021 12:51 AM
Can you provide a transformer with a larger capacity than a three-phase 300 kVA isolation transformer?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we can customize the voltage according to customer needs. Just send us the necessary product specifications, and we will provide technical and commercial quotations.
Can you customize your 300kVA isolation transformer to comply with K4 transformers standard?
5
Heather
Avatar
11/11/2021 7:26 PM
Can you customize your 300kVA isolation transformer to comply with K4 transformers standard?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, of course, but the price will be a bit higher.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Three phase 300 kVA isolation transformer offers consistent, smooth voltage transformation at 480V AC input, 480V to 400V version or 400V to 480V is available, and other voltages can be customized.

Generally, isolation transformers with power above 150KVA will be equipped with an alarm, which is used to detect the temperature of the transformer. When the temperature of the transformer rises to 150 degrees, the alarm will be triggered. At this time, the transformer needs to be manually suspended or stopped. Wait until the transformer temperature returns to normal, then continue to use.

300 kVA Isolation Transformer Specifications

BasicsModelATO-SG300KVA
Phase3 phase
Capacity300 kVA
Weight of Aluminium Wire TransformerOpen type: 740kg
Protected type: 890kg
Weight of Copper Wire TransformerOpen type: 930kg
Protected type: 1005kg
Technical ParametersPrimary Voltage480V (Optional: 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Secondary Voltage400V (Optional: 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Frequency50Hz / 60 Hz
Winding MaterialAluminium/Copper wire (Optional)
Work Efficiency≥95%
Insulation Resistance≥50 MΩ
Electrical Strength3000V AC/1 min
Noise<35-65dB (1 meter)
Insulation GradeH level
Wiring ModeDyn11
Cooling ModeDry type air cooling
Overload CapacityAllow more than 1.2 times rated load to work for up to 4 hours
Enclosure Protection GradeIP 22
CertificateCE, ISO
Warranty12 months
Working EnvironmentTemperature-15℃~+40℃
Humidity≤90%RH, without condensation
Altitude<1000m, non corrosive gas and conductive dust

Note:
Transformer can only convert voltage and CANNOT convert frequency.
Transformer CANNOT convert single phase voltage to 3 phase voltage.
Input/output voltage, power rating and whether with shell of all transformers, can be customized according to clients' requirements.

3 Phase Isolation Transformer Schematic Diagram

ATO isolation transformers schematic diagram

3 Phase Isolation Transformer Details

High capacity isolation transformer details

300 kVA Isolation Transformer Installation Dimension

150kVA 800kVA isolation transformer dimension

Aluminium Wire Transformer SizeCopper Wire Transformer Size
Open type: a*b*c=1060**450*955mmOpen type: a*b*c=990**410*855mm
Mouting size: d*e=600*400mmMouting size: d*e=600*400mm
Protected type: A*B*C=1300*750*1600mmProtected type: A*B*C=1300*750*1600mm

Tips: Using isolation transformer to reduce the zero voltage of UPS

For medium and small power UPS, generally, an isolation transformer is installed at its output part; for a three-in to three-out high-power UPS, the transformer is usually at its bypass input. This method can eliminate the problem that zero voltage is low before the UPS powering on while zero voltage rises after UPS turning on. The UPS power system makes no negative impact on the power grid and load through this method.

Product reviews
300kVA isolation transformer can be customized
5
Kacey
Avatar
3/24/2021 12:51 AM
Can you provide a transformer with a larger capacity than a three-phase 300 kVA isolation transformer?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we can customize the voltage according to customer needs. Just send us the necessary product specifications, and we will provide technical and commercial quotations.
Can you customize your 300kVA isolation transformer to comply with K4 transformers standard?
5
Heather
Avatar
11/11/2021 7:26 PM
Can you customize your 300kVA isolation transformer to comply with K4 transformers standard?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, of course, but the price will be a bit higher.
Only registered users can write reviews