3 Pole Definite Purpose Contactor, 20 amp ~ 90 amp

$59.60
Buy a 3 pole definite purpose contactor at low cost. It is an ac contactor that has 24V, 110V/120V, 208V/240V, 277V coil voltage and works at 50/60 Hz. Wide current range 20 amp ~ 90 amp DP contactor for selection. Air conditioner contactor is an electrically operated switching device, used for the heating, ventilation, air conditioning and refrigeration (HVAC) industry.
SKU: ATO-DPC-3P
*
*
This product has a minimum quantity of 100
Free Shipping
Delivery date: 10-20 days

Get a high performance 3 pole definite purpose contactor at low price. It is an HVAC contactor that has 24V, 110V/120V, 208V/240V, 277V coil voltage. Wide current range 20 amp ~ 90 amp DP contactor for selection. Air conditioner contactor provides compact load control, designed for motors and compressors in resistance heating, air conditioning and refrigeration, and food service equipment.

Features

  • DP contactor has a wide current range (from 20 A to 90 A)
  • Standard AC operating coil ranges for control circuit applications: 24V, 120V, 208-240V, and 277V.
  • 1 pole, 2 pole, 3 pole and 4 pole definite purpose contactors are available.
  • Various contact configurations from 1 pole to 4 pole.
  • UL certification, CSA certification.

Specifications

ModelATO-XKJL1-3P
Pole3
Coil Voltage24V, 110V/120V, 208V/240V, 277V AC
Hertz50/60 Hz
Temperature Range:- 40°F to + 150° F / - 40°C to + 65° C
Mechanical Life1, 000, 000 times
Electrical Life250, 000 times
CertificateUL/CCC

Technical Parameter

ModelFLA (A)LRA (A)LRA (A)LRA (A)LRA (A)PhaseResistive Amps Rating
480V AC600V AC277V AC240V AC277V AC
ATO-XKJL1-3P2010080120120330
25125100150150335
30150120180180340
40200160240240350
50240200240300365
60300240240360375
75300-300450390
90360-3605403120

3 Pole 20-40 FLA Definite Purpose Contactor Dimension (Unit: inch)

"3

3 Pole 50-60 FLA Definite Purpose Contactor Dimension (Unit: mm)

"3

3 Pole 75-90 FLA Definite Purpose Contactor Dimension (Unit: mm)

"3

Tips for using the AC contactor

  • The open type cannot be used inflammable and explosive places and all places with a lot of conductive dust, nor can it be used outdoors without protective measures because sparks and arcs are generated when the load is disconnected.
  • When using, pay attention to whether the contacts and coils are overheated. The three-phase main contacts must be synchronized, and the arc must not be too large when breaking.
  • When the AC contactor controls the motor or circuit, it must be used in conjunction with an overcurrent protector. The contactor itself has no overcurrent protection performance.
  • The suction surface of the short-circuit ring and the electromagnet should be kept intact and clean.
  • Due to poor heat dissipation conditions, when the contactor is installed in the control box or protective enclosure, the ambient temperature is relatively high, so the capacity should be appropriately reduced for use.

In this video we will try to clear the confusion many people have between relays and contactors by showing you how to tell the difference based on five criteria: Definition, Capacity, Structure, Contacts and Applications.

Product reviews
Worked for my needs!
5
Adam
Avatar
3/30/2022 12:09 AM
I just received this 3 pole definite purpose contactor. And I couldn't help testing it. Surprisingly easy to install and it just does the job! It is a good deal and I highly recommend it.
Was this review helpful? Yes No (0/0)
Performs well
5
Sarah
Avatar
4/22/2022 1:06 AM
Arrived quickly and worked as we wanted. I used 3 pole DP contactor to replace an old contactor in my air conditioner and it worked great and saved us a lot of money.
Was this review helpful? Yes No (0/0)
Works as expected
5
Pearl
Avatar
4/22/2022 1:44 AM
My old contactor had a bad contact and I used it to replace a worn relay. This 3P definite purpose contactor has higher amperage-rated contacts than I need. I hope it will last a long time.
Was this review helpful? Yes No (0/0)
Pretty good
5
Albin
Avatar
4/22/2022 2:03 AM
I purchased a 3P 75amp contactor for the condensing unit of my central air conditioning system. It's been working for me for over a month. I would recommend this product to friends.
Was this review helpful? Yes No (0/0)
Works great
5
Cucci
Avatar
4/25/2022 12:07 AM
I am very satisfied with the DP contactor, it looks very well made. I will buy it again when my air conditioner needs it. I love products from the seller.
Was this review helpful? Yes No (0/0)
Good for HVAC
5
Mcilraith
Avatar
4/25/2022 7:54 PM
I received the product quickly. It's a replacement part for my HVAC. I hope it will last for many years.
Was this review helpful? Yes No (0/0)
Works very well
5
Johnny
Avatar
10/26/2022 1:52 AM
The 3P definite purpose contactor is the perfect replacement for my old one. The AC unit is now back up and running. So far it's been working fine and I haven't had any issues.
Was this review helpful? Yes No (0/0)
Just as described
5
Brumberg
Avatar
10/27/2022 1:19 AM
So far, so good. The 3 pole 90A definite purpose contactor fit precisely and are super easy to install. It takes about 15 minutes to replace the old contactor and replace it.
Was this review helpful? Yes No (0/0)
DP contactor works good
5
Gordon
Avatar
10/30/2022 9:43 PM
This 3P pole DP contactor fits directly into my air conditioner. It took about 15 minutes to install and the AC started working again, I hope it will last a long time.
Was this review helpful? Yes No (0/0)
Easy Installation
5
Fiora
Avatar
11/23/2023 12:33 AM
The contactor is designed for straightforward installation, with clearly marked terminals and a user-friendly layout. This ease of installation contributes to time efficiency for both professionals and DIY enthusiasts.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Get a high performance 3 pole definite purpose contactor at low price. It is an HVAC contactor that has 24V, 110V/120V, 208V/240V, 277V coil voltage. Wide current range 20 amp ~ 90 amp DP contactor for selection. Air conditioner contactor provides compact load control, designed for motors and compressors in resistance heating, air conditioning and refrigeration, and food service equipment.

Features

  • DP contactor has a wide current range (from 20 A to 90 A)
  • Standard AC operating coil ranges for control circuit applications: 24V, 120V, 208-240V, and 277V.
  • 1 pole, 2 pole, 3 pole and 4 pole definite purpose contactors are available.
  • Various contact configurations from 1 pole to 4 pole.
  • UL certification, CSA certification.

Specifications

ModelATO-XKJL1-3P
Pole3
Coil Voltage24V, 110V/120V, 208V/240V, 277V AC
Hertz50/60 Hz
Temperature Range:- 40°F to + 150° F / - 40°C to + 65° C
Mechanical Life1, 000, 000 times
Electrical Life250, 000 times
CertificateUL/CCC

Technical Parameter

ModelFLA (A)LRA (A)LRA (A)LRA (A)LRA (A)PhaseResistive Amps Rating
480V AC600V AC277V AC240V AC277V AC
ATO-XKJL1-3P2010080120120330
25125100150150335
30150120180180340
40200160240240350
50240200240300365
60300240240360375
75300-300450390
90360-3605403120

3 Pole 20-40 FLA Definite Purpose Contactor Dimension (Unit: inch)

"3

3 Pole 50-60 FLA Definite Purpose Contactor Dimension (Unit: mm)

"3

3 Pole 75-90 FLA Definite Purpose Contactor Dimension (Unit: mm)

"3

Tips for using the AC contactor

  • The open type cannot be used inflammable and explosive places and all places with a lot of conductive dust, nor can it be used outdoors without protective measures because sparks and arcs are generated when the load is disconnected.
  • When using, pay attention to whether the contacts and coils are overheated. The three-phase main contacts must be synchronized, and the arc must not be too large when breaking.
  • When the AC contactor controls the motor or circuit, it must be used in conjunction with an overcurrent protector. The contactor itself has no overcurrent protection performance.
  • The suction surface of the short-circuit ring and the electromagnet should be kept intact and clean.
  • Due to poor heat dissipation conditions, when the contactor is installed in the control box or protective enclosure, the ambient temperature is relatively high, so the capacity should be appropriately reduced for use.
Product reviews
Worked for my needs!
5
Adam
Avatar
3/30/2022 12:09 AM
I just received this 3 pole definite purpose contactor. And I couldn't help testing it. Surprisingly easy to install and it just does the job! It is a good deal and I highly recommend it.
Was this review helpful? Yes No (0/0)
Performs well
5
Sarah
Avatar
4/22/2022 1:06 AM
Arrived quickly and worked as we wanted. I used 3 pole DP contactor to replace an old contactor in my air conditioner and it worked great and saved us a lot of money.
Was this review helpful? Yes No (0/0)
Works as expected
5
Pearl
Avatar
4/22/2022 1:44 AM
My old contactor had a bad contact and I used it to replace a worn relay. This 3P definite purpose contactor has higher amperage-rated contacts than I need. I hope it will last a long time.
Was this review helpful? Yes No (0/0)
Pretty good
5
Albin
Avatar
4/22/2022 2:03 AM
I purchased a 3P 75amp contactor for the condensing unit of my central air conditioning system. It's been working for me for over a month. I would recommend this product to friends.
Was this review helpful? Yes No (0/0)
Works great
5
Cucci
Avatar
4/25/2022 12:07 AM
I am very satisfied with the DP contactor, it looks very well made. I will buy it again when my air conditioner needs it. I love products from the seller.
Was this review helpful? Yes No (0/0)
Good for HVAC
5
Mcilraith
Avatar
4/25/2022 7:54 PM
I received the product quickly. It's a replacement part for my HVAC. I hope it will last for many years.
Was this review helpful? Yes No (0/0)
Works very well
5
Johnny
Avatar
10/26/2022 1:52 AM
The 3P definite purpose contactor is the perfect replacement for my old one. The AC unit is now back up and running. So far it's been working fine and I haven't had any issues.
Was this review helpful? Yes No (0/0)
Just as described
5
Brumberg
Avatar
10/27/2022 1:19 AM
So far, so good. The 3 pole 90A definite purpose contactor fit precisely and are super easy to install. It takes about 15 minutes to replace the old contactor and replace it.
Was this review helpful? Yes No (0/0)
DP contactor works good
5
Gordon
Avatar
10/30/2022 9:43 PM
This 3P pole DP contactor fits directly into my air conditioner. It took about 15 minutes to install and the AC started working again, I hope it will last a long time.
Was this review helpful? Yes No (0/0)
Easy Installation
5
Fiora
Avatar
11/23/2023 12:33 AM
The contactor is designed for straightforward installation, with clearly marked terminals and a user-friendly layout. This ease of installation contributes to time efficiency for both professionals and DIY enthusiasts.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews