3 Phase 1 hp (750W) Regenerative Blower, 380V, 85 cfm

$817.31
Oil-free design high pressure regenerative blower runs with three-phase 1 hp motor, the air exhaust is cleaner. It has the capacity of 145 m³/ h (85 cfm) maximum airflow, -160 rated vacuum pressure, 160 mbar rated compress pressure. Buffer airflow can reduce noise and shock.
SKU: ATO-RB-380-750
Free Shipping
Delivery date: 6-12 days

Buy 750W 380 volt high-power vortex blower for industrial suction, aquaculture, textile industry, etc. The quality is good but the price is low.

Specification

ModelATO-2PB410H16
Phase3
Frequency50
Power1 hp (750W)
Voltage (AC)△220-240V / Y345-415V
Current4.0△ A / 2.3Y A
Max airflow145 m³/ h (85 cfm)
Rated vacuum pressure-160 mbar
Rated compress pressure160 mbar
Noise63 dB (A)
Weight20 kg

Dimention (Unit: mm)

Dimension of ATO 1.1hp regenerative blower

ABCDEFGHJKLMNOPQΦRSUV (1~)V' (1~)V1 (3~)V1' (3~)YXZX-HOLESΦX
28630211522525529216015412095130707546G11/472123M6X19//M25X1.5M16X1.5M6X150°/ 120°/ 240°174

Details

Regenerative Blower Details

Tips: High pressure regenerative blowers installation tips

  • Use flat washers and spring washers to tighten the screws.
  • It is best to use rubber buffer rubber to withstand the weight of high pressure blowers, especially for high power regenerative blowers, rubber buffer rubber is essential.
  • For some occasions that have requirements for noise, a silencer can be installed to reduce the noise (in general, it is reduced by about 5dB), and the silencer is installed at the end of the air inlet pipe or the air outlet pipe.
  • For some occasions with high requirements for noise, a layer of silencer sponge can be added according to the conditions of the high pressure regenerative blower itself to meet the noise requirements on site.
  • When using silencing foam, pay attention to the distance between the high pressure regenerative blower and the cabinet, and pay attention to the ventilation and heat dissipation of the high pressure vortex blower.
  • The inlet and outlet pipes of the high pressure blower should be connected with hoses to isolate vibration.

Proposition 65 Warning

*WARNING: This product can expose you to chemicals, including lead, which is known to the State of California to cause birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.

Product reviews
Powerful 3-phase regenerative blower
5
Yeager
Avatar
5/26/2022 2:33 AM
I've been looking a regenerative blower to fit my work, after 2 days I bought a blower from ATO. I was so surprised beacause the 1hp regenerative blower works so powerful and steady! I didn't take so much time to install it. I highly recommend it!
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Buy 750W 380 volt high-power vortex blower for industrial suction, aquaculture, textile industry, etc. The quality is good but the price is low.

Specification

ModelATO-2PB410H16
Phase3
Frequency50
Power1 hp (750W)
Voltage (AC)△220-240V / Y345-415V
Current4.0△ A / 2.3Y A
Max airflow145 m³/ h (85 cfm)
Rated vacuum pressure-160 mbar
Rated compress pressure160 mbar
Noise63 dB (A)
Weight20 kg

Dimention (Unit: mm)

Dimension of ATO 1.1hp regenerative blower

ABCDEFGHJKLMNOPQΦRSUV (1~)V' (1~)V1 (3~)V1' (3~)YXZX-HOLESΦX
28630211522525529216015412095130707546G11/472123M6X19//M25X1.5M16X1.5M6X150°/ 120°/ 240°174

Details

Regenerative Blower Details

Tips: High pressure regenerative blowers installation tips

  • Use flat washers and spring washers to tighten the screws.
  • It is best to use rubber buffer rubber to withstand the weight of high pressure blowers, especially for high power regenerative blowers, rubber buffer rubber is essential.
  • For some occasions that have requirements for noise, a silencer can be installed to reduce the noise (in general, it is reduced by about 5dB), and the silencer is installed at the end of the air inlet pipe or the air outlet pipe.
  • For some occasions with high requirements for noise, a layer of silencer sponge can be added according to the conditions of the high pressure regenerative blower itself to meet the noise requirements on site.
  • When using silencing foam, pay attention to the distance between the high pressure regenerative blower and the cabinet, and pay attention to the ventilation and heat dissipation of the high pressure vortex blower.
  • The inlet and outlet pipes of the high pressure blower should be connected with hoses to isolate vibration.
Product reviews
Powerful 3-phase regenerative blower
5
Yeager
Avatar
5/26/2022 2:33 AM
I've been looking a regenerative blower to fit my work, after 2 days I bought a blower from ATO. I was so surprised beacause the 1hp regenerative blower works so powerful and steady! I didn't take so much time to install it. I highly recommend it!
Was this review helpful? Yes No (0/0)
Only registered users can write reviews
Customers who bought this item also bought

3 Phase 1/2 hp (400W) Regenerative Blower, 380V, 47 cfm

ATO-RB-380-400
$693.62
Lower cost regenerative blower is configured with a 380V motor and the power output is 400W (1/ 2 hp). It has the air flow capacity of 80m³ per hour (47 cfm). Rated vacuum pressure is -120 mbar, rated compress pressure is 130 mbar.

3 Phase 2 hp (1.5kW) Regenerative Blower, 380V, 124cfm

ATO-RB-380-1500
$924.69
ATO best sale three-phase regenerative blower has high-power and large airflow, which are 2 hp and 124 cfm respectively. 380V power supply, -200 mbar rated vacuum pressure, 190 mbar rated compress pressure. High pressure, built-in protection, good heat dissipation performance, not easy to burn.