25kV Vacuum Circuit Breaker

$3,702.41
Vacuum circuit breaker for sale online, with 25kv rated voltage to be the protection and control unit. Rate current of vcb circuit breaker is 630A, 1250A, 2500A, 3150A. Acting to protect and control line is the function of vcb.
SKU: ATO-VCB-25
*
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Delivery date: 6-12 days

High voltage vacuum circuit breaker with 25kV rated voltage. Rated short circuit switching current is 50kA, 80kA, 100kA. Advantages of vcb breaker are reliable insulation, no pollution and long time free maintenance.

Features:

  • Ideal contact material and shape, ensuring low current carrying value and stable contact resistance.
  • Vacuum circuit breaker with with integrated design of main conductive circuit made of compound isolation material and operating mechanism.
  • VCB circuit breaker with few components and parts, compact and logical structure, assuring more reliable and safer operation.
  • Compact design enables the breaker to be installed within almost all switchgears.
  • Superior cost performance, ideal choice for engineering programs.

Parameter List: (Parameters can be customized)

ModelATO-VCB-25
Rated voltage25 kV
Maximum operating voltage25 kV
Rated current630A/1000A/1250A1250A/1600A/2000A/2500A1250A/1600A/2000A/3150A2000A/2500A/3150A
Rated short circuit breaking current20kA/25kA31.5kA40kA50kA
Rated short circuit closing current50kA/63kA80kA100kA125kA
Rated peak withstand current50kA/63kA80kA100kA125kA
4S Rated short-time withstand current20kA/25kA31.5kA40kA50kA
Rated insulation levelpower frequency withstand voltage(rated open circuit before and later): 42 kV
impulse withstand voltage(rated open circuit before and later): 75 kV
Mechanical life20000 times
Rated closing voltage of operating mechanism (DC)110 V, 220 V
Rated switching voltage of operating mechanism (DC)110 V, 220 V
Contactor torque11±1
Exceed range(the compress length of contact spring)4±0.5
Max.bouncing duration≤ 2
Average opening speed≤ 0.05
Average closing speed≤ 0.08
Opening time≤ 50
Closing time≤ 100
Accumulative allowable wear thickness of dynamic and static contacts3 mm
CertificationCE
Warranty12 months

Dimensions: (Unit: mm)

Vacuum circuit breaker inside constructionVacuum circuit breaker external construction

Schematic Diagram:

Vacuum circuit breaker schematic diagram

Details

25KV Vacuum Circuit Breaker Details

Tips: How to Maintenance Vacuum Circuit Breaker?

  • Insulation.

This is one of the simplest maintenance techniques. Insulation maintenance applies to the cleaning of all the insulation surfaces. Any soft cloth, such as dry lint-free cloth or dry paper towel can be used to wipe the dust off from the insulation surfaces to ensure it smooth operation.

If wiping is unable to remove dust well, distilled water or a mild solvent can be used to remove. Once wiped, make sure that all the surfaces have completely dried up before placing the circuit breaker into use.

  • Lubrication.

Proper lubrication is required periodically to ensure the overall smooth and correct operation of all the components of a vacuum circuit breaker and VCB maintenance. The gap between relubrication depends on the frequency of the circuit breaker used.

For lubrication, a drop of light machine oil can be used. After lubrication, the circuit breaker needs to be operated several times manually and electrically so that the oil is absorbed into the parts.

Types of Circuit Breakers

In this video, we'll take a closer look at the meaning behind these abbreviations and explain the types of circuit breakers they represent. By understanding the different types of circuit breakers on the market, you can make an informed decision and choose the right type for your specific requirements, thereby enhancing the protection of your electrical infrastructure.

Isolator vs Circuit Breaker

Although isolators and circuit breakers have similar functions in a circuit, they are two separate entities. This video explains you the difference between the two devices in terms of working, features, operation, affordability, etc. You can choose between them based on your specific requirements.

Product reviews
Strongly recommend to everyone to buy
5
Mergatroid
Avatar
1/16/2022 10:50 PM
This is a very good 25kV vacuum circuit breaker. I bought it through the recommendation of a colleague. I think its quality is very good. I will also recommend it to everyone to buy it.
Was this review helpful? Yes No (0/0)
Superb vacuum breaker
5
Beeyh
Avatar
4/25/2022 7:20 PM
I have been using this vacuum circuit breaker for a month. It works very well. No problems have been found so far. I will recommend this product to other people who need it.
Was this review helpful? Yes No (0/0)
Working fine
5
Monzer
Avatar
7/19/2022 7:44 PM
What I've been looking for is a 25 kV vacuum circuit breaker. I took it out as soon as I received it. I put this vcb breaker in my factory and it's been working fine.
Was this review helpful? Yes No (0/0)
Solid 25kV vacuum circuit breaker
5
Dozzie
Avatar
11/4/2022 1:19 AM
When I bought it, I saw the solid case of the vacuum circuit breaker in the picture. After receiving the goods, it was almost the same as the picture. I was very satisfied. This 25kV vacuum circuit breaker performance is also excellent.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

High voltage vacuum circuit breaker with 25kV rated voltage. Rated short circuit switching current is 50kA, 80kA, 100kA. Advantages of vcb breaker are reliable insulation, no pollution and long time free maintenance.

Features:

  • Ideal contact material and shape, ensuring low current carrying value and stable contact resistance.
  • Vacuum circuit breaker with with integrated design of main conductive circuit made of compound isolation material and operating mechanism.
  • VCB circuit breaker with few components and parts, compact and logical structure, assuring more reliable and safer operation.
  • Compact design enables the breaker to be installed within almost all switchgears.
  • Superior cost performance, ideal choice for engineering programs.

Parameter List: (Parameters can be customized)

ModelATO-VCB-25
Rated voltage25 kV
Maximum operating voltage25 kV
Rated current630A/1000A/1250A1250A/1600A/2000A/2500A1250A/1600A/2000A/3150A2000A/2500A/3150A
Rated short circuit breaking current20kA/25kA31.5kA40kA50kA
Rated short circuit closing current50kA/63kA80kA100kA125kA
Rated peak withstand current50kA/63kA80kA100kA125kA
4S Rated short-time withstand current20kA/25kA31.5kA40kA50kA
Rated insulation levelpower frequency withstand voltage(rated open circuit before and later): 42 kV
impulse withstand voltage(rated open circuit before and later): 75 kV
Mechanical life20000 times
Rated closing voltage of operating mechanism (DC)110 V, 220 V
Rated switching voltage of operating mechanism (DC)110 V, 220 V
Contactor torque11±1
Exceed range(the compress length of contact spring)4±0.5
Max.bouncing duration≤ 2
Average opening speed≤ 0.05
Average closing speed≤ 0.08
Opening time≤ 50
Closing time≤ 100
Accumulative allowable wear thickness of dynamic and static contacts3 mm
CertificationCE
Warranty12 months

Dimensions: (Unit: mm)

Vacuum circuit breaker inside constructionVacuum circuit breaker external construction

Schematic Diagram:

Vacuum circuit breaker schematic diagram

Details

25KV Vacuum Circuit Breaker Details

Tips: How to Maintenance Vacuum Circuit Breaker?

  • Insulation.

This is one of the simplest maintenance techniques. Insulation maintenance applies to the cleaning of all the insulation surfaces. Any soft cloth, such as dry lint-free cloth or dry paper towel can be used to wipe the dust off from the insulation surfaces to ensure it smooth operation.

If wiping is unable to remove dust well, distilled water or a mild solvent can be used to remove. Once wiped, make sure that all the surfaces have completely dried up before placing the circuit breaker into use.

  • Lubrication.

Proper lubrication is required periodically to ensure the overall smooth and correct operation of all the components of a vacuum circuit breaker and VCB maintenance. The gap between relubrication depends on the frequency of the circuit breaker used.

For lubrication, a drop of light machine oil can be used. After lubrication, the circuit breaker needs to be operated several times manually and electrically so that the oil is absorbed into the parts.

Product reviews
Strongly recommend to everyone to buy
5
Mergatroid
Avatar
1/16/2022 10:50 PM
This is a very good 25kV vacuum circuit breaker. I bought it through the recommendation of a colleague. I think its quality is very good. I will also recommend it to everyone to buy it.
Was this review helpful? Yes No (0/0)
Superb vacuum breaker
5
Beeyh
Avatar
4/25/2022 7:20 PM
I have been using this vacuum circuit breaker for a month. It works very well. No problems have been found so far. I will recommend this product to other people who need it.
Was this review helpful? Yes No (0/0)
Working fine
5
Monzer
Avatar
7/19/2022 7:44 PM
What I've been looking for is a 25 kV vacuum circuit breaker. I took it out as soon as I received it. I put this vcb breaker in my factory and it's been working fine.
Was this review helpful? Yes No (0/0)
Solid 25kV vacuum circuit breaker
5
Dozzie
Avatar
11/4/2022 1:19 AM
When I bought it, I saw the solid case of the vacuum circuit breaker in the picture. After receiving the goods, it was almost the same as the picture. I was very satisfied. This 25kV vacuum circuit breaker performance is also excellent.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews