Hi, I am interested in the pumps you sell. In my application, I am flowing room-temperature water at up to 150 GPM. My discharge head is about 130 psi.
Specifically, I am using this pump to flow coolant water through a heat exchanger, and this is the source of the 130 psi pressure drop. I would like the pump to be able to overcome at least 200 psi of discharge head since I am using a flow-restricting proportional valve upstream of the heat exchanger to control flow through it.
The pump will be right next to the heat exchanger and at approximately the same level so there shouldn’t be any additional discharge head. Because of this high head and flow rate, I am thinking that this will require two pumps in series unless it can be accomplished with just one pump.
I will be needing to be able to turn this pump on and off (start and stop the flow) remotely and be able to do PLC control. I have the capability to provide 480V three-phase power at 60 Hz.
Could you please recommend pump(s) for my application and provide pump curves? Can you please provide a quote?
I am operating outdoors, open to the weather. The ambient temperature ranges from 20 deg. F to 110 deg. F.
Get a 3-phase 25 hp vertical centrifugal pump at a reasonable price. It has 61m3/h maximum flow, 63m minimum head, 73m maximum head and 80mm diameter of inlet and outlet. Input voltage AC 220V/380V/400V/460V to 480V and input frequency 50Hz/60Hz for selection.
Features:
- The centrifugal pump has a vertical structure, and its inlet and outlet have the same diameter. The inlet and outlet are on the same centerline so that they can be installed in the pipeline like a valve. If a protective cover is added, it can be used in the open air.
- Easy to install and maintain. There is no need to dismantle the piping system, just remove the connecting flat nut of the vertical pump. All rotor parts can then be removed.
- The vertical pump can be installed vertically or horizontally according to the requirements of the piping system.
- Vertical centrifugal pumps can be run in series or in parallel according to the requirements of flow and head.
Specification
- Model: ATO-VCP-80-250A
- Power: 25 hp (18.5kW)
- Number of stages: Single stage
- Input voltage: AC 220V~480V
- Input frequency: 50Hz/60Hz
- Inlet diameter: 80mm (3 inch)
- Outlet diameter: 80mm (3 inch)
- Flow (min. flow to max. flow): 32.5m3/h (143 gpm), 46.7m3/h (206 gpm), 61m3/h (269 gpm)
- Head (max. head to min. head): 73m (240ft), 70m (230ft), 63m (207ft)
- Efficiency: 52%, 59%, 60%
- Installation mode: Vertical type or horizontal type
- Nominal diameter of impeller: 250mm
- Size: 480*430*820mm
- Weight: 188kg
Vertical centrifugal pump dimension (unit: mm):

| Boundary dimension | L | B | H | C1*B1 |
| 480 | 430 | 820 | 160*200 | |
| Installation dimension | A | C2*B2 | 4-Φd1 | |
| 130 | 110*170 | 4-Φ18 | ||
| Flange dimension | D | D1 | n-φd | |
| φ200 | φ160 | 8-φ18 | ||
Details

Tips: Why can't centrifugal pumps pump water?
It means the centrifugal pump has the following faults: Be unable to pump water, has difficulty in start-up, or the flow is reduced.
Reasons for not being able to pump
- Insufficient injection of liquid before pumping.
- Air or air leakage in the pump or suction tube.
- The suction height exceeds the allowable range of the pump.
- The pipeline resistance is too high.
- There is debris in the pump or pipeline.
- The motor is overloaded.