25 amp Reversing AC Contactor with Mechanical Interlock

$87.99
3 pole/ 4 pole normally open mechanical interlocking AC contactor is a combination of two reversing contactor and a mechanical interlock, coil rated voltage from 24V AC, 36V, 48V to 380V, rated operational current 25 amp, which meets IEC standard.
SKU: ATO-ACCON-25N
*
*
Free Shipping
Delivery date: 6-12 days

AC magnetic reversing contactor with mechanical interlock is suitable for using in the circuits (rated voltage 24V, 36V, 48V to 380V AC 50Hz or 60Hz). The mechanical interlock is an interference type which locks at the beginning of the stroke of any AC contactor.

Specification

ModelATO-CJX2-25N
Rated Operational Current380VAC-325A
AC-48.5A
660VAC-318A
AC-44.4A
Conventional Heating Current40A
Rated Insulation Voltage690V
Power of Controllable 3-phase Squirrel-cage Motor (AC-3)220V5.5kW
380V11kW
660V15kW
Operational FrequencyElectric LifeAC-31200 times/h
AC-4150 times/h
Mechanical Life3600 times/h
Service LifeElectric Life (104 Operations)AC-3100
AC-420
Mechanical Life (104 Operations)1000
Matching Fusing ModelRT16-32
Average Power Consumption (20℃) @ 50HzPick-up110VA
Holding11VA
Contact Form (Optional)3P (Additional 1NO Auxiliary Contact) or 4P
Rail Size35mm
Ambient Temperature-5℃~+40℃
Altittude≤2000m
Class of PollutionClass 3
Installation CategoryⅢ
Dimensions168 x 86 x 95mm
Weight1.5kg

Tips: Mechanical interlock AC contactor wiring

Mechanical interlock means that two AC reversing contactors cannot be closed at the same time. It is generally used in the motor forward and reverse circuit. If the two AC contactors are closed at the same time, a short circuit between the power phases will occur. The electrical interlock wiring is: the normally closed contact of the contactor is connected in series with the coil circuit of the contactor, and the normally closed contact of the contactor is connected in series with the coil circuit required for contact. However, if the contacts of a contactor are welded, the electrical interlock will fail. Therefore, contactors with mechanical interlocks must be used for places with strict requirements. The two contactors insert their respective auxiliary normally closed contact reserves into the other's control circuit and lock each other so that the two contactors cannot be closed at the same time. This circuit is relatively simple. The general principle is to ensure that the motor cannot be turned on when the motor is rotating in the forward direction, and it cannot be turned on when the motor is rotating in the reverse direction. Short-circuit, so it is necessary to add a lock in the loop, and then it is required to stop the motor operation at any time regardless of reverse or forward rotation. Therefore, the stop button must be connected in series and the button must be connected in parallel.

In this video we will try to clear the confusion many people have between relays and contactors by showing you how to tell the difference based on five criteria: Definition, Capacity, Structure, Contacts and Applications.

Product reviews
Precise design
5
chenrrry
Avatar
8/26/2025 8:07 PM
This is a 3-pole normally open mechanical interlock AC contactor, which is a combination of two reversing contactors and a mechanical interlock. This IEC-compliant, 25-ampere-rated Mechanical Interlock AC Contacter has a very precise mechanical interlock design, making it impossible for the two contactors to close at the same time, providing crucial safety protection for our forward and reverse motor applications.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

AC magnetic reversing contactor with mechanical interlock is suitable for using in the circuits (rated voltage 24V, 36V, 48V to 380V AC 50Hz or 60Hz). The mechanical interlock is an interference type which locks at the beginning of the stroke of any AC contactor.

Specification

ModelATO-CJX2-25N
Rated Operational Current380VAC-325A
AC-48.5A
660VAC-318A
AC-44.4A
Conventional Heating Current40A
Rated Insulation Voltage690V
Power of Controllable 3-phase Squirrel-cage Motor (AC-3)220V5.5kW
380V11kW
660V15kW
Operational FrequencyElectric LifeAC-31200 times/h
AC-4150 times/h
Mechanical Life3600 times/h
Service LifeElectric Life (104 Operations)AC-3100
AC-420
Mechanical Life (104 Operations)1000
Matching Fusing ModelRT16-32
Average Power Consumption (20℃) @ 50HzPick-up110VA
Holding11VA
Contact Form (Optional)3P (Additional 1NO Auxiliary Contact) or 4P
Rail Size35mm
Ambient Temperature-5℃~+40℃
Altittude≤2000m
Class of PollutionClass 3
Installation CategoryⅢ
Dimensions168 x 86 x 95mm
Weight1.5kg

Tips: Mechanical interlock AC contactor wiring

Mechanical interlock means that two AC reversing contactors cannot be closed at the same time. It is generally used in the motor forward and reverse circuit. If the two AC contactors are closed at the same time, a short circuit between the power phases will occur. The electrical interlock wiring is: the normally closed contact of the contactor is connected in series with the coil circuit of the contactor, and the normally closed contact of the contactor is connected in series with the coil circuit required for contact. However, if the contacts of a contactor are welded, the electrical interlock will fail. Therefore, contactors with mechanical interlocks must be used for places with strict requirements. The two contactors insert their respective auxiliary normally closed contact reserves into the other's control circuit and lock each other so that the two contactors cannot be closed at the same time. This circuit is relatively simple. The general principle is to ensure that the motor cannot be turned on when the motor is rotating in the forward direction, and it cannot be turned on when the motor is rotating in the reverse direction. Short-circuit, so it is necessary to add a lock in the loop, and then it is required to stop the motor operation at any time regardless of reverse or forward rotation. Therefore, the stop button must be connected in series and the button must be connected in parallel.

Product reviews
Precise design
5
chenrrry
Avatar
8/26/2025 8:07 PM
This is a 3-pole normally open mechanical interlock AC contactor, which is a combination of two reversing contactors and a mechanical interlock. This IEC-compliant, 25-ampere-rated Mechanical Interlock AC Contacter has a very precise mechanical interlock design, making it impossible for the two contactors to close at the same time, providing crucial safety protection for our forward and reverse motor applications.
Was this review helpful? Yes No (0/0)