3 Phase AC Vacuum Contactor, 200A, 1140V

$343.11
Rated 1140V, 200A ac vacuum contactor is used for frequently switch on and off the normal working current. 3 phase, 36 volt or 220 volt control circuit, 2±0.2 mm open distance, 80±20 N final power, 1500000 times electrical life.
SKU: ATO-VCON-200
*
Free Shipping
Delivery date: 6-12 days

Buy best 4 pole contactor with vacuum tube at the lowest price on ATO. AC 50Hz or 60Hz, 4200 volt main circuit, 2500 volt auxiliary circuit, 2000 volt control circuit.

Specification

ModelATO-CJZ-200
Rated voltageMain circuit1140V
Control circuit (AC)36V, 220V
Rated current200A
Main contact parameterOpen distance2±0.2 mm
Over distance>1 mm
Final power80±20 N
Power frequency withstand voltageMain circuit4200V
Auxiliary circuit2500V
Control circuit2000V
Phase3
Number of Pole4
FrequencyAC 50Hz or 60Hz
Making capacity10 le 100 times
Breaking capacity8 le 25 times
Max making & breaking capacity (A)2000 3 times
Electric lifeAC3600000 times
AC460000 times
Electrical life1500000 times
FunctionDevice protection
Electricity typeVacuum
Ambient temperature-25℃ to 40℃
Packaging detailsStandard package or according to customer's requirements
Weight6.5kg

AC vacuum contactor outline and installation dimension (Unit: mm)

AC vacuum contactor outline and installation dimension

Tips: Vacuum ac contactor troubleshooting

Whether the vacuum ac contactor is faulty or not can be judged according to whether it can be closed and opened accurately and reliably and kept in the closing and opening positions. The failure of the main circuit can be found and eliminated from the routine inspection and maintenance of the vacuum ac contactor. The common failure analysis of vacuum ac contactor is as follows:

  • Inability to store energy: Inability to store energy is one of the common failures of vacuum contactors, especially the energy storage mechanism driven by ratchets and pawls has a higher probability of failure. The energy storage mechanism to complete the energy storage action mainly depends on the three links of the energy storage motor, the drive mechanism, and the positioning parts. Grasping these three links firmly, it is easy to find out the cause of the ac vacuum contactor failure.
  • No closing action: The fault here is mainly related to whether the closing electromagnet is closed, whether the energy storage is in place, and whether the positioning member is operating normally.
  • The ac vacuum contactor has a closing action but fails to close. When analyzing this type of failure, you should first analyze the lock, and then analyze whether it is related to the energy storage part.
  • The ac vacuum contactor does not open: It should be emphasized here that when the vacuum ac contactor refuses to move or closes, before analyzing and repairing the main body of the contactor, it is necessary to fully judge whether the reason is in the control and secondary components such as auxiliary switches, terminal blocks, etc., and then analyze and diagnose the contactor.

In this video we will try to clear the confusion many people have between relays and contactors by showing you how to tell the difference based on five criteria: Definition, Capacity, Structure, Contacts and Applications.

Product reviews
Our questions about contractors
5
Guez
Avatar
1/12/2022 12:51 AM
We have forwarded the requirement to our purchase team. They will contact you for purchase of (ADC50& ADC200)? So that the logs connected to the terminals never come in contact with each other.
Was this review helpful? Yes No (0/0)
ATO Responded
Don't provide isolation protection between terminals. But we recommend covering your terminals with protective silicone.
Satisfactory reliability and smoother equipment operation.
4
nancy
Avatar
9/13/2023 7:58 PM
This 3-phase AC vacuum contactor is really quite good! Its high current capacity (200A) and high voltage (1140V) allow me to cope with all kinds of circuit requirements without any worries at all. Secondly, I am satisfied with its reliability and I no longer have to worry about sudden circuit interruptions. Importantly, this contactor runs very smoothly without any noise or vibration occurring, making my equipment run smoother.
Was this review helpful? Yes No (0/0)
Durability needs to be improved
4
Dale2010
Avatar
10/8/2023 9:40 PM
I bought the 3-phase AC vacuum contactor and found it to be average. Even though it has a current capacity of 200A and a voltage of 1140V, I have had occasional minor problems with it. Sometimes there is a slight noise, which is not very loud, but still makes me feel a little uncomfortable. Also, it doesn't seem to last as long as I would have hoped. While the performance is good, I need to look further into its reliability. I hope to have a better experience in the future.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Buy best 4 pole contactor with vacuum tube at the lowest price on ATO. AC 50Hz or 60Hz, 4200 volt main circuit, 2500 volt auxiliary circuit, 2000 volt control circuit.

Specification

ModelATO-CJZ-200
Rated voltageMain circuit1140V
Control circuit (AC)36V, 220V
Rated current200A
Main contact parameterOpen distance2±0.2 mm
Over distance>1 mm
Final power80±20 N
Power frequency withstand voltageMain circuit4200V
Auxiliary circuit2500V
Control circuit2000V
Phase3
Number of Pole4
FrequencyAC 50Hz or 60Hz
Making capacity10 le 100 times
Breaking capacity8 le 25 times
Max making & breaking capacity (A)2000 3 times
Electric lifeAC3600000 times
AC460000 times
Electrical life1500000 times
FunctionDevice protection
Electricity typeVacuum
Ambient temperature-25℃ to 40℃
Packaging detailsStandard package or according to customer's requirements
Weight6.5kg

AC vacuum contactor outline and installation dimension (Unit: mm)

AC vacuum contactor outline and installation dimension

Tips: Vacuum ac contactor troubleshooting

Whether the vacuum ac contactor is faulty or not can be judged according to whether it can be closed and opened accurately and reliably and kept in the closing and opening positions. The failure of the main circuit can be found and eliminated from the routine inspection and maintenance of the vacuum ac contactor. The common failure analysis of vacuum ac contactor is as follows:

  • Inability to store energy: Inability to store energy is one of the common failures of vacuum contactors, especially the energy storage mechanism driven by ratchets and pawls has a higher probability of failure. The energy storage mechanism to complete the energy storage action mainly depends on the three links of the energy storage motor, the drive mechanism, and the positioning parts. Grasping these three links firmly, it is easy to find out the cause of the ac vacuum contactor failure.
  • No closing action: The fault here is mainly related to whether the closing electromagnet is closed, whether the energy storage is in place, and whether the positioning member is operating normally.
  • The ac vacuum contactor has a closing action but fails to close. When analyzing this type of failure, you should first analyze the lock, and then analyze whether it is related to the energy storage part.
  • The ac vacuum contactor does not open: It should be emphasized here that when the vacuum ac contactor refuses to move or closes, before analyzing and repairing the main body of the contactor, it is necessary to fully judge whether the reason is in the control and secondary components such as auxiliary switches, terminal blocks, etc., and then analyze and diagnose the contactor.
Product reviews
Our questions about contractors
5
Guez
Avatar
1/12/2022 12:51 AM
We have forwarded the requirement to our purchase team. They will contact you for purchase of (ADC50& ADC200)? So that the logs connected to the terminals never come in contact with each other.
Was this review helpful? Yes No (0/0)
ATO Responded
Don't provide isolation protection between terminals. But we recommend covering your terminals with protective silicone.
Satisfactory reliability and smoother equipment operation.
4
nancy
Avatar
9/13/2023 7:58 PM
This 3-phase AC vacuum contactor is really quite good! Its high current capacity (200A) and high voltage (1140V) allow me to cope with all kinds of circuit requirements without any worries at all. Secondly, I am satisfied with its reliability and I no longer have to worry about sudden circuit interruptions. Importantly, this contactor runs very smoothly without any noise or vibration occurring, making my equipment run smoother.
Was this review helpful? Yes No (0/0)
Durability needs to be improved
4
Dale2010
Avatar
10/8/2023 9:40 PM
I bought the 3-phase AC vacuum contactor and found it to be average. Even though it has a current capacity of 200A and a voltage of 1140V, I have had occasional minor problems with it. Sometimes there is a slight noise, which is not very loud, but still makes me feel a little uncomfortable. Also, it doesn't seem to last as long as I would have hoped. While the performance is good, I need to look further into its reliability. I hope to have a better experience in the future.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews
Customers who bought this item also bought

25A Star Delta Starter, 11kW/ 18.5kW, 220V/ 380V AC

ATO-STAR-25
$169.80
25A starting current star delta starter for 3 phase induction motor circuit control, economic price, 11kW/ 18.5kW power, working at 220V or 380V AC voltage, optional contact form 3P+NO or 3P+NC. This y △ motor connection starter consists of 3 contactors and an air delay head for 15Hp or 25Hp motor.

32A Star Delta Starter, 15kW/ 25kW, 220V/ 380V AC

ATO-STAR-32
$193.32
32 amps starting current star delta starter for 3 phase induction motor circuit control, economic price, working at 15kW/ 25kW power, 220V or 380V AC voltage available, optional contact form 3P+NO or 3P+NC. This wye delta motor connection starter consists of 3 contactors and an air delay head for 20Hp or 34Hp asynchronous motor.