200 MHz Digital Oscilloscope, 2 Channels, 2 GSa/s

$1,517.78
Cost-effective 200 MHz digital storage oscilloscope comes with 2 channels, 2 GSa/s sampling rate. Digital oscilloscopes have the advantages of waveform triggering, storage, display, measurement, and waveform data analysis and processing.
SKU: ATO-SCOPE-200M2
Free Shipping
Delivery date: 6-12 days

Dual channel digital oscilloscope is a 2 channels oscilloscope, with 200 MHz bandwidth, 2 GSa/s sampling rate and 8 bits vertical resolution. The DSO oscilloscope has a pass/ fail function and trigger synchronous output function, and current measurement function.

Specification

ModelATO-EDS-202C
Bandwidth200 MHz
Channel2+ external trigger
Sample rate2 GSa/s
Acquisition modelSample, Peak detect
Record length10M
Display8 inch LCD
Waveform refresh rate10000 wfrms/s
Input couplingDC, AC, Ground
Probe attenuation1X, 10X, 100X, 1000X
Input Impedance1MΩ ± 2%, in parallel with 15pF ± 5pF
Max. input voltage400V (DC+AC, PK - PK)
Bandwidth limit(typical)20MHz / Full bandwidth
Sampling rate range2ns/div ~ 100s/div,step by 1-2-5
Vertical Resolution8 bits
Sensitivity Resolution2mV/div~10V/div
Low Frequency(-3db)≥10 Hz (at input, AC coupling)
Rise time (at input, Typical)≤1.7ns
Trigger typeEdge
Trigger modelAuto, Normal, single
Trigger level range±6 div from the screen center
Automatic measurementVpp, Vavg, Vrms, Frequency, Period, Vmax, Vmin, Vtop, Vbase, Vamp, Overshoot,
Preshoot, Rise Time, Fall Time, +Width, -Width, +Duty, -Duty, DelayA→B , DelayA→B
Cursor measurementΔV, ΔT, ΔT&ΔV between cursors,auto cursor
Dimension340*155*70mm
Weight1.8kg

Accessories

  • Power cable
  • USB cable
  • Probe
  • Probe Adjust
  • Quick Guide

Dimension

Dimension of 100 MHz digital oscilloscope

Details

200 MHz Digital Oscilloscope Details

Tips: Some transient signals of the digital oscilloscope are lost, how to capture and reproduce them?

Set it to single-shot acquisition mode (trigger mode is set to Normal, trigger condition is set to edge trigger, and trigger level is adjusted to an appropriate value, and then sweep mode is set to single-shot mode), note that the storage depth of the oscilloscope will determine your The time at which the signal can be acquired and the maximum sampling rate that can be used.

Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Dual channel digital oscilloscope is a 2 channels oscilloscope, with 200 MHz bandwidth, 2 GSa/s sampling rate and 8 bits vertical resolution. The DSO oscilloscope has a pass/ fail function and trigger synchronous output function, and current measurement function.

Specification

ModelATO-EDS-202C
Bandwidth200 MHz
Channel2+ external trigger
Sample rate2 GSa/s
Acquisition modelSample, Peak detect
Record length10M
Display8 inch LCD
Waveform refresh rate10000 wfrms/s
Input couplingDC, AC, Ground
Probe attenuation1X, 10X, 100X, 1000X
Input Impedance1MΩ ± 2%, in parallel with 15pF ± 5pF
Max. input voltage400V (DC+AC, PK - PK)
Bandwidth limit(typical)20MHz / Full bandwidth
Sampling rate range2ns/div ~ 100s/div,step by 1-2-5
Vertical Resolution8 bits
Sensitivity Resolution2mV/div~10V/div
Low Frequency(-3db)≥10 Hz (at input, AC coupling)
Rise time (at input, Typical)≤1.7ns
Trigger typeEdge
Trigger modelAuto, Normal, single
Trigger level range±6 div from the screen center
Automatic measurementVpp, Vavg, Vrms, Frequency, Period, Vmax, Vmin, Vtop, Vbase, Vamp, Overshoot,
Preshoot, Rise Time, Fall Time, +Width, -Width, +Duty, -Duty, DelayA→B , DelayA→B
Cursor measurementΔV, ΔT, ΔT&ΔV between cursors,auto cursor
Dimension340*155*70mm
Weight1.8kg

Accessories

  • Power cable
  • USB cable
  • Probe
  • Probe Adjust
  • Quick Guide

Dimension

Dimension of 100 MHz digital oscilloscope

Details

200 MHz Digital Oscilloscope Details

Tips: Some transient signals of the digital oscilloscope are lost, how to capture and reproduce them?

Set it to single-shot acquisition mode (trigger mode is set to Normal, trigger condition is set to edge trigger, and trigger level is adjusted to an appropriate value, and then sweep mode is set to single-shot mode), note that the storage depth of the oscilloscope will determine your The time at which the signal can be acquired and the maximum sampling rate that can be used.

Only registered users can write reviews