2 hp (1.5 kW) AC Line Reactor, 3 Phase Input

$231.36
2 hp (1.5 kW) vfd line reactor for sale, 5 amps rated current, 380 volt, other voltages can be customized, 3 phase input line reactor is the ideal choice for 3 phase VFD.
SKU: ATO-ILR-1d5
*
*
Free Shipping
Delivery date: 6-12 days

High quality 2 hp AC line reactor, rated current 5 Amps, 3 phase input, working frequency 50Hz/60 Hz. Voltage can choose 380V, 400V, 440V, 460V and 480V. It is a light weight, low cost and long life line reactor.

Specifications

BasicsModelATO-ACR-0005-2M80-0.4SC
Recommended VFD ModelGK3000-4T0015G (2 hp three phase VFD)
Phase3 Phase
Power2 hp (1.5 kW)
Weight2.5 kg
Technical ParametersWork Voltage380V (Optional: 220V/ 240V/ 400V/ 415V/ 440V/ 460V/ 480V)
Work Frequency50Hz/ 60Hz
Rated Current5 A
Max Current1.5 Times the Rated Current, Continued 60s
Inductance Value2.8 mH
MaterialAluminium/Copper (Optional)
Voltage Drop2%
Noise≤65dB
Insulation ClassClass F, H
Protection ClassIP00-IP22
Insulation Resistor≥100MΩ
Working EnvironmentOperation Environment-10℃~+45℃
Temperature Rise≤85K
Humidity≤90%RH, without condensation
Running Ambient Temperature-25℃~+45℃
Altitude≤2000m

VFD Line Reactor Size & Circuit Diagram

Ac reactor sizeCircuit diagram

Dimension (±5mm)
LDWW1HA×B
115mm90mm95mm68mm135mm6×11

Tips: Function of AC Input Line Reactor

AC input line reactor can restrain the harmonic current, improve the power factor and weaken the impact of surge voltage and current in the input circuit, weaken the influence of the power supply voltage imbalance, use it to limit the voltage mutation of the power grid and the current impact caused by overvoltage, smooth the peak pulse contained in the voltage of the power supply, and effectively protect the frequency conversion. AC line reactor can not only prevent interference from power grid, but also reduce the pollution caused by harmonic current generated by rectifier unit.

Product reviews
Perfect 2hp line reactor
5
Kroh
Avatar
8/24/2021 9:33 PM
I just bought a VFD from ATO.com and read the description on the page that this 2hp line reactor can be used for VFD. Now I will buy the line reactor again to see if it can be used as described on the page.
Was this review helpful? Yes No (0/0)
2 hp VFD usage matters
5
leon
Avatar
2/6/2023 1:06 AM
Can I run the VFD and do programming before | connect the motor?
Does the unit get damaged if you power it without a load connected?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, you can run the VFD and do programming before connect the motor, also you can power it without a load connected, no problem.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

High quality 2 hp AC line reactor, rated current 5 Amps, 3 phase input, working frequency 50Hz/60 Hz. Voltage can choose 380V, 400V, 440V, 460V and 480V. It is a light weight, low cost and long life line reactor.

Specifications

BasicsModelATO-ACR-0005-2M80-0.4SC
Recommended VFD ModelGK3000-4T0015G (2 hp three phase VFD)
Phase3 Phase
Power2 hp (1.5 kW)
Weight2.5 kg
Technical ParametersWork Voltage380V (Optional: 220V/ 240V/ 400V/ 415V/ 440V/ 460V/ 480V)
Work Frequency50Hz/ 60Hz
Rated Current5 A
Max Current1.5 Times the Rated Current, Continued 60s
Inductance Value2.8 mH
MaterialAluminium/Copper (Optional)
Voltage Drop2%
Noise≤65dB
Insulation ClassClass F, H
Protection ClassIP00-IP22
Insulation Resistor≥100MΩ
Working EnvironmentOperation Environment-10℃~+45℃
Temperature Rise≤85K
Humidity≤90%RH, without condensation
Running Ambient Temperature-25℃~+45℃
Altitude≤2000m

VFD Line Reactor Size & Circuit Diagram

Ac reactor sizeCircuit diagram

Dimension (±5mm)
LDWW1HA×B
115mm90mm95mm68mm135mm6×11

Tips: Function of AC Input Line Reactor

AC input line reactor can restrain the harmonic current, improve the power factor and weaken the impact of surge voltage and current in the input circuit, weaken the influence of the power supply voltage imbalance, use it to limit the voltage mutation of the power grid and the current impact caused by overvoltage, smooth the peak pulse contained in the voltage of the power supply, and effectively protect the frequency conversion. AC line reactor can not only prevent interference from power grid, but also reduce the pollution caused by harmonic current generated by rectifier unit.

Product reviews
Perfect 2hp line reactor
5
Kroh
Avatar
8/24/2021 9:33 PM
I just bought a VFD from ATO.com and read the description on the page that this 2hp line reactor can be used for VFD. Now I will buy the line reactor again to see if it can be used as described on the page.
Was this review helpful? Yes No (0/0)
2 hp VFD usage matters
5
leon
Avatar
2/6/2023 1:06 AM
Can I run the VFD and do programming before | connect the motor?
Does the unit get damaged if you power it without a load connected?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, you can run the VFD and do programming before connect the motor, also you can power it without a load connected, no problem.
Only registered users can write reviews