This 2A/3A/5A adjustable DC power supply combines automatic CV/CC switching with stable output, digital voltage and current monitoring, and forced-air cooling. Built-in OVP, OTP, overload, and short-circuit protection support safe long-term operation across various resistive, capacitive, and inductive loads. Order now for versatile DC power applications.
Specification
| Model | ATO-JK10002K | ATO-JK10003K | ATO-JK10005K |
| Input Voltage Range | Single Phase AC 220V ±15% | Single Phase AC 220V ±10% | Single Phase AC 220V ±15% |
| Output Voltage | DC 0–1000V Continuously Adjustable | DC 0–1000V Continuously Adjustable | DC 0–1000V Continuously Adjustable |
| Output Current | 0–2A Continuously Adjustable | 0–3A Continuously Adjustable | 0–5A Continuously Adjustable |
| Output Power | 2000W | 3000W | 5000W |
| Input Frequency | 50Hz/60Hz | ||
| Source Regulation | ≤0.5%+10mV | ||
| Load Regulation | ≤0.5%+10mV | ||
| Ripple | ≤1%+10mVrms | ≤0.8%+10mVrms | |
| Voltage Display | 3-digit digital meter | 3.5-digit digital meter | 4-digit digital meter |
| Accuracy: ±0.5% + 1 digit (10%–100% rated value) | Accuracy: ±0.5% + 1 digit (10%–100% rated value) | Accuracy: ±0.5% + 1 digit (10%–100% rated value) | |
| Display format: 000V–1000V | Display format: 000V–1000V | Display format: 0000V–1000V | |
| Current Display | 3-digit digital meter | 3.5-digit digital meter | 4-digit digital meter |
| Accuracy: ±0.5% + 1 digit (10%–100% rated value) | Accuracy: ±0.5% + 1 digit (10%–100% rated value) | Accuracy: ±0.5% + 1 digit (10%–100% rated value) | |
| Display format: 00.0A–2.0A | Display format: 00.0A–3.00A | Display format: 00.00A–5.00A | |
| Insulation Resistance | Input to Output: ≥20MΩ | ||
| Input to Chassis: ≥20MΩ | |||
| Output to Chassis: ≥80MΩ | |||
| Dielectric Strength | Input to Output: AC1500V, 10mA, 1 min | ||
| Input to Chassis: AC1500V, 10mA, 1 min | |||
| Output to Chassis: AC1500V, 10mA, 1 min | |||
| Output Over-Voltage Protection | Built-in OVP, protection value: rated value +5% | ||
| Output Over-Current Protection | Overload & short-circuit constant current output | ||
| Over-Temperature Protection | Built-in OTP, protection at 85℃±5% (heatsink temperature) | ||
| Voltage / Current Setting | Potentiometer | ||
| Output Polarity | Output positive (+) / negative (-) can be grounded arbitrarily | ||
| Cooling Method | Forced Air Cooling | ||
| Operating Environment | Temp: -10℃~40℃ (Indoor use) | Temp: -10℃~60℃ (Indoor use) | Temp: -10℃~40℃ (Indoor use) |
| Humidity: 10%~85% RH (Indoor use) | |||
| Storage Environment | Temp: -20℃~70℃ | ||
| Humidity: 10%~90% RH | |||
| Cabinet Dimension (L*W*H) | 430mm*255mm*155mm | 530mm*430mm*200mm | 530mm*430mm*200mm |
| Weight | 12 kg | 25 kg | 25 kg |
| Notes | All values are typical values. Deviations may occur under different load or other conditions.Accuracy is measured under load-side voltage detection. Deviations between actual and rated values may exist due to temperature error and component aging. | ||
Features
- Continuously Adjustable Output: The DC power supply provides continuous 0–1000V DC output, with 2A, 3A, and 5A current options. Voltage and current are continuously adjustable from zero to rated values to meet various high-voltage DC power requirements.
- Automatic CV/CC Switching: The variable DC power supply automatically switches between constant voltage (CV) and constant current (CC) modes according to load conditions, providing stable voltage or current regulation for different testing applications.
- PWM Switching Technology: Advanced PWM switching control gives the power supply high conversion efficiency and stable output performance compared with conventional linear power supply designs.
- High-Stability Output: The power supply features voltage stability of ≤0.5%+10mV and load stability of ≤0.5%+30mV, helping maintain consistent DC output under changing load conditions.
- Low-Ripple Output: With ripple as low as ≤0.8%+10mVrms depending on the model, the power supply provides cleaner DC output for electronic testing, R&D, and precision power applications.
- Multiple Protection Functions: Built-in OVP, OTP, overload, and short-circuit protection help protect the power supply and connected loads against abnormal operating conditions.
- Soft-Start Output: The adjustable power supply uses a delayed soft-start function to reduce output voltage overshoot when powered on, improving startup stability and protecting connected equipment.
Dimension (unit: mm)
2A:

3A/5A:

Details
2A:

3A/5A:


Tips: How to choose the output range of a DC power supply?
Choose a DC power supply with voltage and current ranges covering the actual load requirements with reasonable headroom. Set the voltage range about 10%–20% above the rated load voltage and the current range 20%–30% above maximum demand, allowing more margin for loads with inrush current. Also verify the power limit at the required voltage and current, and consider CV/CC modes, derating, ripple, noise, resolution, accuracy, and required communication interfaces.