150 hp (110 kW) AC Line Reactor, 3 Phase Output

$896.87
150 hp vfd line reactor, 3 phase outout, with super high performance, rated current 250 amps, copper or aluminum for selection, attractive appearance, low noise, high protection class and durability. Low price and directly selling by manufacturer.
SKU: ATO-OLR-110
Free Shipping
Delivery date: 6-12 days
150 hp (110 kW) 3-phase AC output line reactor is characterized by rared current 250A, work freqency 50/60Hz, voltage and materials can be selected, cheap and easy to operate.

3-Phase Output Line Reactor Specifications

BasicModelATO-ACR-0090-0M16-0.4SC
Recommended VFD Model GK3000-4T1100G (50 hp three phase VFD)
Phase3 Phase
Power150 hp (110 kW)
Weight18 kg
Technical ParametersWork Voltage380V (optional: 220V/ 240V/ 400V/ 415V/ 440V/ 460V/ 480V)
Work Frequency50 Hz/60 Hz
Rated Current90 A
Max Current1.5 Times the Rated Current, Continued 60s
Inductance Value0.028 mH
MaterialAluminium/Copper (Optional)
Voltage Drop2%
Noise≤65dB
Insulation ClassClass F, H
Protection ClassIP00-IP22
Insulation Resistor≥100MΩ
Working EnvironmentOperation Environment-10℃~+45℃
Temperature Rise≤85K
Humidity≤90%RH, without condensation
Running Ambient Temperature-25℃~+45℃
Altitude≤2000m

3-Phase Output Line Reactor Mounting Dimension

15hp (11kW) 3 phase line reactor

Dimension(±5mm)
LDWW1HA×B
2501821759823011×18

3-Phase Output Line Reactor Circuit Diagram

3 phase output line reactor circuit diagram

Tips: How to solve the surface discharging of line reactor?

Dry air parallel line reactor doesn’t have any form of surface discharge in dry state. When it is raining, the parts with low temperature rise have conductive water film and high surface leakage current. Near end backflow lead row with concentrated surface electric leakage and the spots on the surface of waist have dirty and wet charge and electric leakage traces. Hydrophobic coating can restrain leakage current and prevent any form of surface discharge effectively.

The end adopts the improvement measures of pre-burried annular current sharing electrode structure to solve the concentrated current leakage on lower end surface. Electric arcs can be prevented even without hydrophobic coating or when hydrophobic coating fails. As the currently best structure improvement measure, rainhat and rain protection layer can restrain surface current leakage to some extent.

 

Product reviews
Meet my expectations of the output line reactor for vfd
5
Martines
Avatar
11/8/2018 7:37 PM
Thank you very much. With the help of the engineer, I have installed the 110 kW output line reactor that just arrived. It has been running for 5 days.
This 3 phase output line reactor performance is stable and noise is small. I trust that I will visit ATO.com again.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*
150 hp (110 kW) 3-phase AC output line reactor is characterized by rared current 250A, work freqency 50/60Hz, voltage and materials can be selected, cheap and easy to operate.

3-Phase Output Line Reactor Specifications

BasicModelATO-ACR-0090-0M16-0.4SC
Recommended VFD Model GK3000-4T1100G (50 hp three phase VFD)
Phase3 Phase
Power150 hp (110 kW)
Weight18 kg
Technical ParametersWork Voltage380V (optional: 220V/ 240V/ 400V/ 415V/ 440V/ 460V/ 480V)
Work Frequency50 Hz/60 Hz
Rated Current90 A
Max Current1.5 Times the Rated Current, Continued 60s
Inductance Value0.028 mH
MaterialAluminium/Copper (Optional)
Voltage Drop2%
Noise≤65dB
Insulation ClassClass F, H
Protection ClassIP00-IP22
Insulation Resistor≥100MΩ
Working EnvironmentOperation Environment-10℃~+45℃
Temperature Rise≤85K
Humidity≤90%RH, without condensation
Running Ambient Temperature-25℃~+45℃
Altitude≤2000m

3-Phase Output Line Reactor Mounting Dimension

15hp (11kW) 3 phase line reactor

Dimension(±5mm)
LDWW1HA×B
2501821759823011×18

3-Phase Output Line Reactor Circuit Diagram

3 phase output line reactor circuit diagram

Tips: How to solve the surface discharging of line reactor?

Dry air parallel line reactor doesn’t have any form of surface discharge in dry state. When it is raining, the parts with low temperature rise have conductive water film and high surface leakage current. Near end backflow lead row with concentrated surface electric leakage and the spots on the surface of waist have dirty and wet charge and electric leakage traces. Hydrophobic coating can restrain leakage current and prevent any form of surface discharge effectively.

The end adopts the improvement measures of pre-burried annular current sharing electrode structure to solve the concentrated current leakage on lower end surface. Electric arcs can be prevented even without hydrophobic coating or when hydrophobic coating fails. As the currently best structure improvement measure, rainhat and rain protection layer can restrain surface current leakage to some extent.

 

Product reviews
Meet my expectations of the output line reactor for vfd
5
Martines
Avatar
11/8/2018 7:37 PM
Thank you very much. With the help of the engineer, I have installed the 110 kW output line reactor that just arrived. It has been running for 5 days.
This 3 phase output line reactor performance is stable and noise is small. I trust that I will visit ATO.com again.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews