1.5 kVA 50 kV AC DC Hipot Tester

$2,448.95
Low price high voltage hipoter test capacity 1.5 kVA, 50 Hz or 60 Hz, 50 kV, it can be used for AC DC hipot test of cable, LCD display control box, convenient and easy to use. Special capacity can be customized, manufacturer direct sales.
SKU: ATO-HTGTB-1550
*
*
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Delivery date: 6-12 days

1.5 kVA portable AC DC hipot test, single phase, 50 Hz, it is widely used in high voltage test of household appliances, wire and cable, instrumentation and other products, and the ultimate withstand voltage test of insulating materials.

Note: AC leakage current meter is not provided.

Specification

ModelATO-HTGTB-1550
Capacity1.5 kVA
Input Voltage110V/ 120V/ 220V
Frequency50Hz/ 60Hz
Output Voltage50 kV
Current30 mA
DC Output70 kV
Phase1 Phase
Weight (Transformer + Control Box)43 kg
Cooling MethodDry
Effeciency90%
Impedance Voltage<12%
Surface Temperature Raising< 55°C
No Load Current< 4%
Output Voltage WaveformSine Wave
UsageAC DC Hipot Tester
Warranty12 Months
Temperature Environment0~40°C
Altitude<2000m
Relative Humidity<85%

Packing List

NO.DescriptionQuantity
1Hipot Test Set (1 Control Box + 1.5 kVA Dry Transformer)1
2Power Supply Cable1
3Earth Cable1
4Connecting Line1
5Fuse3
6Rectifying Diode1
7User Manual1

Wiring Diagram

AC hipot test dimension
DC hipot test


Tips:
Safety Guidelines for Using Hipot Tester

  1. The arrangement of the hipot test equipment should have sufficient safety distance for the person and the surrounding area. Try to avoid arranging equipment and applying high voltage test leads on the personnel aisle.
  2. The DC high voltage test micro-ampere meter is preferably at a high potential. In addition to the shielding box, there should be an overcurrent automatic protection device to prevent sudden breakdown of the table or short-circuit discharge.
  3. Power frequency withstand voltage test, please pay attention to check whether the equipment capacity is sufficient and can avoid resonance.
  4. The working ground wire (high voltage tail, voltage stabilizing capacitor end grounding wire) and protective earth wire (control box casing) should be reliably grounded separately.
  5. If the power supply is irregularly oscillated during the test, it must affect the high-voltage output stability. In this case, please wait for the impact power such as electric welding to pause for a while or find other reasons.
  6. The test requirements for the climate (temperature, humidity) meet the requirements of the test procedures, and shielding measures must be taken when necessary.
  7. If the voltmeter pointer swings greatly during the test, the ammeter indication increases sharply or the test article has smoke, flashover or abnormal burnt sound. The test should be stopped immediately, the power supply should be cut off, and the cause should be checked.

The video will show you how to connect ATO AC DC Hipot Tester.

AC/DC Hipot Tester Test

This video will show you how to use the ATO Hipot Tester.

Product reviews
Value for money hipot tester
5
Theon
Avatar
7/22/2019 1:09 AM
Hesitated for a long time before buying 1.5 kVA hipot tester, I can't wait to test after receiving it. A good  hipot tester, so far, works well and there has been no fire.
Was this review helpful? Yes No (0/0)
Really helpful in my experiment
5
Keran
Avatar
12/7/2022 8:52 PM
I've had this hipot tester for about five months. I used it as soon as I received it, and so far there have been no problems. This hipot tester helped me a lot in my experiment.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

1.5 kVA portable AC DC hipot test, single phase, 50 Hz, it is widely used in high voltage test of household appliances, wire and cable, instrumentation and other products, and the ultimate withstand voltage test of insulating materials.

Note: AC leakage current meter is not provided.

Specification

ModelATO-HTGTB-1550
Capacity1.5 kVA
Input Voltage110V/ 120V/ 220V
Frequency50Hz/ 60Hz
Output Voltage50 kV
Current30 mA
DC Output70 kV
Phase1 Phase
Weight (Transformer + Control Box)43 kg
Cooling MethodDry
Effeciency90%
Impedance Voltage<12%
Surface Temperature Raising< 55°C
No Load Current< 4%
Output Voltage WaveformSine Wave
UsageAC DC Hipot Tester
Warranty12 Months
Temperature Environment0~40°C
Altitude<2000m
Relative Humidity<85%

Packing List

NO.DescriptionQuantity
1Hipot Test Set (1 Control Box + 1.5 kVA Dry Transformer)1
2Power Supply Cable1
3Earth Cable1
4Connecting Line1
5Fuse3
6Rectifying Diode1
7User Manual1

Wiring Diagram

AC hipot test dimension
DC hipot test


Tips:
Safety Guidelines for Using Hipot Tester

  1. The arrangement of the hipot test equipment should have sufficient safety distance for the person and the surrounding area. Try to avoid arranging equipment and applying high voltage test leads on the personnel aisle.
  2. The DC high voltage test micro-ampere meter is preferably at a high potential. In addition to the shielding box, there should be an overcurrent automatic protection device to prevent sudden breakdown of the table or short-circuit discharge.
  3. Power frequency withstand voltage test, please pay attention to check whether the equipment capacity is sufficient and can avoid resonance.
  4. The working ground wire (high voltage tail, voltage stabilizing capacitor end grounding wire) and protective earth wire (control box casing) should be reliably grounded separately.
  5. If the power supply is irregularly oscillated during the test, it must affect the high-voltage output stability. In this case, please wait for the impact power such as electric welding to pause for a while or find other reasons.
  6. The test requirements for the climate (temperature, humidity) meet the requirements of the test procedures, and shielding measures must be taken when necessary.
  7. If the voltmeter pointer swings greatly during the test, the ammeter indication increases sharply or the test article has smoke, flashover or abnormal burnt sound. The test should be stopped immediately, the power supply should be cut off, and the cause should be checked.
Product reviews
Value for money hipot tester
5
Theon
Avatar
7/22/2019 1:09 AM
Hesitated for a long time before buying 1.5 kVA hipot tester, I can't wait to test after receiving it. A good  hipot tester, so far, works well and there has been no fire.
Was this review helpful? Yes No (0/0)
Really helpful in my experiment
5
Keran
Avatar
12/7/2022 8:52 PM
I've had this hipot tester for about five months. I used it as soon as I received it, and so far there have been no problems. This hipot tester helped me a lot in my experiment.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews