10kW (12.5kVA) Silent Diesel Generator, 1 Phase/3 Phase

$5,600.79
10kW (12.5kVA) portable diesel generator with good price and high performance, 50Hz/60Hz at 120V, 220V, 230V, powerful single cylinder 4-stroke air cooled diesel engine, designed for home and industrial use. Single phase or three phase silent generator is in stock.
SKU: ATO-DG-10K
*
*
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Delivery date: 6-12 days

Description

Three phase or single phase small diesel generator is 12.5kVA rated power, with V-twin air cooled single cylinder engine, 30L large fuel tank ensuring 11 hours of continuous output, four wheels for easy move. Portable and quiet generator is ideal for home emergency use or as standby power supply.

Specifications

ModelDG14000SE
GeneratorFrequency50Hz60Hz
AC Voltage120V, 220V, 230V, 120/240V, 220/380V, 230/400V
Rated AC Output9.5kW9.7kW
Max. AC Output10kW10.5kW
Power Factor (cosΦ)cosΦ=0.8
Continuous Working Time11h
Alternator TypeSelf-excited
DC Output12V 8.3A
PhaseSingle or Three phase
Noise Level at 7m70-73dB
Fuel Tank Capacity30L
Starting Battery12V 36AH
*The starting batteries cannot be carried by air so you need to purchase it separately.
CertificateCE, ISO
Working Environment Temperature-10-40°C
EngineModelHR1102F
Engine TypeSingle-cylinder, vertical, 4-stroke air-cooled diesel engine
Bore*Stroke102*88mm
Displacement Capacity718cc
Fuel0# or -10# light diesel oil
Lubrication Oil Volume1.65L
Combustion SystemDirect injection
Standard Configuration
  • Voltmeter*1
  • AC output socker*2
  • AC circuit breaker*1
  • Oil warning light*1
  • Oil alert*1
Optional Configuration
  • DC circuit breaker
  • Calculagraph
  • Big wheel
  • Three phase voltage
  • Current meter
  • ATS
  • Remote control

*Please contact us if you need the above options.

DimensionsDimension (L*W*H)1130*760*860mm
Gross Wight235kg

Tips: Installation method of diesel generator set

The diesel generator set is installed on the concrete floor:

  1. A reinforced concrete base shall be placed on the floor.
  2. The concrete base passes the pressure test of more than 173kpa for one month.
  3. Concrete base shall be at least 150 mm higher than the floor, extend at least 150 mm along each side of the unit chassis, and embed "J" or "L" foundation bolts on the cement base.

The diesel generator set is fixed on the chassis type oil tank:

  1. Engine, shock absorber has been already installed between engine and oil tank.
  2. The structure and strength of the oil tank must be able to bear the static and dynamic loads of the unit.
  3. There must be a certain distance between the tank bottom and the ground for maintenance.

Proposition 65 Warning

*WARNING: This product can expose you to chemicals, including lead, which is known to the State of California to cause birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.

Product reviews
Does the 10kw silent diesel generator have remote start?
5
Richard Carrey
Avatar
7/23/2020 7:14 PM
Does the 10kw silent diesel generator have remote start? ie can it be started and stopped automatically by a solar system to charge the batteries if they run low? Also, can we connect to an external fuel tank?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, it has remote start, but you need to add ATS option when ordering. And you can connect external tank.
GENERATOR NOT CHARGING THE BATTERY
5
simbarashe
Avatar
5/11/2023 6:17 AM
Our 10kW Silent Diesel Generator, 1 Phase/3 Phase is not charging the battery. What could be the problem?

Thank you for assisting.
Was this review helpful? Yes No (0/0)
ATO Responded
Did you buy your generator from the ATO? If yes, please contact our after-sales team.
We would like to get a maintenance kit for the diesel generator?
5
karel
Avatar
6/12/2023 8:31 PM
This generator as described by purchase order is in Zimbabwe. It needs a new electronic controller.
Also, we tried to get new brushes for it. The ones I was told to buy where the wrong size. We would like to get a maintenance kit for the unit including brushes.
Was this review helpful? Yes No (0/0)
ATO Responded
Since this is a 2020 diesel generator, please provide the nameplate label of the generator, the overall front photo and the accessories picture for us to check further and see if we can provide you with the same parts. Thank you for your understanding.
Inquire for your diesel generator
5
Derby
Avatar
1/8/2024 8:24 PM
Our standby diesel generator for our FM broadcast transmitter died.   It is 208 volt three phase, 100 KW.   But we could operate our transmitter at reduced power during an outage and run off a much smaller generator for the time being.  

Could one of your diesel three phase generators work?   Could it connect to our existing automatic transfer switch?   The transfer switch is an Asco series 300 which provides a normally open or normally closed engine start contact.

We need enough fuel capacity to run as long as three or four days as we sometimes have such long power outages.   So could a fuel line be extended from the generator to our existing 75 gallon diesel tank?   The tank is filled with road tax free red dyed diesel.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we have 100kW 208V 3-phase diesel generators that will work for your application.

To be clear beforehand, our generators do Not have UL or EPA certs, do your local authority require mandatory EPA cert for diesel generators, or do you have a way to figure that out?

About the connection to your ATS, you need to send us some pictures for further check.

And for extension fuel lines, how are you doing at present?
Fuel consumption meter
5
Morian
Avatar
8/18/2025 8:22 PM
Do you have a fuel consumption meter for the 10kW (12.5 kVA) silent diesel generator?
Was this review helpful? Yes No (0/0)
ATO Responded
This ATO-DG-10K diesel generator consumes 3.6 liters/hour of fuel when fully loaded.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Description

Three phase or single phase small diesel generator is 12.5kVA rated power, with V-twin air cooled single cylinder engine, 30L large fuel tank ensuring 11 hours of continuous output, four wheels for easy move. Portable and quiet generator is ideal for home emergency use or as standby power supply.

Specifications

ModelDG14000SE
GeneratorFrequency50Hz60Hz
AC Voltage120V, 220V, 230V, 120/240V, 220/380V, 230/400V
Rated AC Output9.5kW9.7kW
Max. AC Output10kW10.5kW
Power Factor (cosΦ)cosΦ=0.8
Continuous Working Time11h
Alternator TypeSelf-excited
DC Output12V 8.3A
PhaseSingle or Three phase
Noise Level at 7m70-73dB
Fuel Tank Capacity30L
Starting Battery12V 36AH
*The starting batteries cannot be carried by air so you need to purchase it separately.
CertificateCE, ISO
Working Environment Temperature-10-40°C
EngineModelHR1102F
Engine TypeSingle-cylinder, vertical, 4-stroke air-cooled diesel engine
Bore*Stroke102*88mm
Displacement Capacity718cc
Fuel0# or -10# light diesel oil
Lubrication Oil Volume1.65L
Combustion SystemDirect injection
Standard Configuration
  • Voltmeter*1
  • AC output socker*2
  • AC circuit breaker*1
  • Oil warning light*1
  • Oil alert*1
Optional Configuration
  • DC circuit breaker
  • Calculagraph
  • Big wheel
  • Three phase voltage
  • Current meter
  • ATS
  • Remote control

*Please contact us if you need the above options.

DimensionsDimension (L*W*H)1130*760*860mm
Gross Wight235kg

Tips: Installation method of diesel generator set

The diesel generator set is installed on the concrete floor:

  1. A reinforced concrete base shall be placed on the floor.
  2. The concrete base passes the pressure test of more than 173kpa for one month.
  3. Concrete base shall be at least 150 mm higher than the floor, extend at least 150 mm along each side of the unit chassis, and embed "J" or "L" foundation bolts on the cement base.

The diesel generator set is fixed on the chassis type oil tank:

  1. Engine, shock absorber has been already installed between engine and oil tank.
  2. The structure and strength of the oil tank must be able to bear the static and dynamic loads of the unit.
  3. There must be a certain distance between the tank bottom and the ground for maintenance.
Product reviews
Does the 10kw silent diesel generator have remote start?
5
Richard Carrey
Avatar
7/23/2020 7:14 PM
Does the 10kw silent diesel generator have remote start? ie can it be started and stopped automatically by a solar system to charge the batteries if they run low? Also, can we connect to an external fuel tank?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, it has remote start, but you need to add ATS option when ordering. And you can connect external tank.
GENERATOR NOT CHARGING THE BATTERY
5
simbarashe
Avatar
5/11/2023 6:17 AM
Our 10kW Silent Diesel Generator, 1 Phase/3 Phase is not charging the battery. What could be the problem?

Thank you for assisting.
Was this review helpful? Yes No (0/0)
ATO Responded
Did you buy your generator from the ATO? If yes, please contact our after-sales team.
We would like to get a maintenance kit for the diesel generator?
5
karel
Avatar
6/12/2023 8:31 PM
This generator as described by purchase order is in Zimbabwe. It needs a new electronic controller.
Also, we tried to get new brushes for it. The ones I was told to buy where the wrong size. We would like to get a maintenance kit for the unit including brushes.
Was this review helpful? Yes No (0/0)
ATO Responded
Since this is a 2020 diesel generator, please provide the nameplate label of the generator, the overall front photo and the accessories picture for us to check further and see if we can provide you with the same parts. Thank you for your understanding.
Inquire for your diesel generator
5
Derby
Avatar
1/8/2024 8:24 PM
Our standby diesel generator for our FM broadcast transmitter died.   It is 208 volt three phase, 100 KW.   But we could operate our transmitter at reduced power during an outage and run off a much smaller generator for the time being.  

Could one of your diesel three phase generators work?   Could it connect to our existing automatic transfer switch?   The transfer switch is an Asco series 300 which provides a normally open or normally closed engine start contact.

We need enough fuel capacity to run as long as three or four days as we sometimes have such long power outages.   So could a fuel line be extended from the generator to our existing 75 gallon diesel tank?   The tank is filled with road tax free red dyed diesel.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we have 100kW 208V 3-phase diesel generators that will work for your application.

To be clear beforehand, our generators do Not have UL or EPA certs, do your local authority require mandatory EPA cert for diesel generators, or do you have a way to figure that out?

About the connection to your ATS, you need to send us some pictures for further check.

And for extension fuel lines, how are you doing at present?
Fuel consumption meter
5
Morian
Avatar
8/18/2025 8:22 PM
Do you have a fuel consumption meter for the 10kW (12.5 kVA) silent diesel generator?
Was this review helpful? Yes No (0/0)
ATO Responded
This ATO-DG-10K diesel generator consumes 3.6 liters/hour of fuel when fully loaded.
Only registered users can write reviews