100 hp Single Phase to Three Phase Converter

$33,984.62
Cheap 100 HP single phase to three phase converter, convert 220V/240V single phase to 380V/415V/480V single phase converter, rated current 193A, output AC power supply is suitable for all types of appliances, power tools, motors, etc. Other voltages can be customized, manufacturer direct sales.
SKU: ATO-PHC-100
*
*
*
*
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Delivery date: 6-12 days

Phase converter 100 hp, 80kW, convert 240 volt single phase to 415 volt 3 phase converter, digital LCD display, output frequency 50Hz or 60Hz.

Note:

  • When the load is a motor, the phase converter should be more than 5~7 times the motor capacity.
  • When the load is soft start + motor, the phase converter should be more than 3 times the motor capacity.
  • When the load is VFD + motor, the phase converter should be more than 1.5~2 times the motor capacity.

Specification:

ModelATO-BZT-80kW
Isolation ModeLow frequency transformer
Input VoltageOptional: 110V/ 120V/ 220V/ 230V/ 240V/ 415V/ 440V/ 480V) single phase 2 wire
Output VoltageOptional: 220V/ 380V/ 400V/ 415V/ 440V/ 480V) 3 phase 4 wire+PE
Input Current246A at 230V (Input Current=Power/Input Voltage/1.414)
Rated Output Power100 hp (80 kW)
Output WaveformPure sine wave
Output Current115.5A at 400V
Frequnecy50Hz or 60Hz
Power Factor1
Overload Ability150%, 5 Seconds
Efficiency>93%
Waveform Distortion Rated (THD)≤3%(Linear load)
Dynamic Respond (0 to 100% load)5%, ≤50ms
DisplayLCD
Running ModeWorking continously
Electrical Inslation Properties2000Vac, 1 Minute
Communication InterfaceRS485 (Optional)
ProtectionInput under voltage, overvoltage, output over-current, short circuit, overheating etc.
Cooling MethodForced air cooling
Short Circuit ProtectionNo automatic recovery, need to restart the machine
Noise (1 meter)≤50dB
Degree of ProtectionIP20 (indoor)
Working Altitude≤2000m
Woorking Temperature-25~+55°C
Relative Humidty0~90%, Non condensing
Dimension750*750*1480mm
Weight590kg

Single Phase
Single phase
Split phase
Split phase

Details

100 hp Single Phase to 3 Phase Converter Details

Feature

1. Single phase to 3 phase converter input voltage, output voltage, frequency and phase can be customized.
2. Pure sine wave output, transient response is less than 50ms, waveform distortion is minimal, conversion efficiency is high, and output voltage is stable.
3. The static phase converter uses a low frequency transformer to ensure that the input voltage and output voltage are completely electrically isolated to avoid interference.
4. Using SVPWM space vector algorithm, high conversion efficiency, high instantaneous power, low no-load loss, conversion efficiency can reach more than 94%, and no-load loss is small.
5. The output AC power supply is suitable for all types of appliances, power tools, motors, etc. Has a higher driving load capacity.
6. 3 Phase converter has the function of filtering out grid interference and interference at the same time, with stable voltage and frequency power performance, and provides a more stable and pure power supply environment for back-end equipment.
7. Complete output protection function, with output overvoltage, overload, short circuit, overheating, self-diagnostic protection and other protection functions.
8. High conversion efficiency, high instantaneous power and low load loss.
9. Two start modes: step-down start and variable frequency start. Customers can set the startup mode according to the load type. Reduce the use of frequency converters, thereby reducing equipment investment costs, easy wiring and control.

single phase to three phase power converter

Tips: What does three-phase electric phase mean?

Phase, also called perimeter, phase is a dimensionless physical quantity, and its unit is radian. "Phase" is a physical quantity used to reflect the state of motion of a vibrating object.
As we all know that when the coil rotates in a magnetic field, the wire cutting the magnetic field line will generate an induced electromotive force, and its change law can be expressed by a sine curve. If we take three coils and place them 120 degrees apart in space, the three coils are still rotating in the magnetic field at the same speed, and three induced electromotive forces of the same frequency will be induced. Because the three coils are 120 degrees away from each other in space, the generated current is also a three-phase sinusoidal change, which is called three-phase sinusoidal alternating current. Industrial power uses three-phase power, such as three-phase AC motors.
In three-phase four-wire power supply, the voltage between the phase line and the neutral (zero line) is the phase voltage; the voltage between any two phase lines is the line voltage; the line voltage is 3 times the phase voltage. The current flowing through each phase load is the phase current, and the current flowing in the phase line is the line current.
The voltage between any two phases is 380V, and the voltage between any two phases is 220V. It is divided into A phase, B phase, and C phase.

In this video, ATO will show static phase converter converting single-phase 220V to three-phase 380V. And this phase converter has VFD technology to start the three-phase asynchronous motor to reduce the impact on the power grid.

Single Phase to Three Phase Converter

In this video, the components of a single phase to three phase converter are introduced.

Phase Converter Powered Up and Running

The video shows the safe operation of an ATO phase converter. ATO offers phase converters from 4hp to 25hp that can convert single-phase power to three-phase power.

Product reviews
Startup is quick and quiet!
5
Eva
Avatar
4/20/2022 3:14 AM
I was careful with the wiring reading the instructions carefully and this thing worked great for me right off the bat. Saved me a pile and now every 3 phase machine I buy for my home hobby machine shop will have one of these in it. Runs the transformer for the relays and interlocks on my lathe controller flawlessly because i followed the instructions.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Phase converter 100 hp, 80kW, convert 240 volt single phase to 415 volt 3 phase converter, digital LCD display, output frequency 50Hz or 60Hz.

Note:

  • When the load is a motor, the phase converter should be more than 5~7 times the motor capacity.
  • When the load is soft start + motor, the phase converter should be more than 3 times the motor capacity.
  • When the load is VFD + motor, the phase converter should be more than 1.5~2 times the motor capacity.

Specification:

ModelATO-BZT-80kW
Isolation ModeLow frequency transformer
Input VoltageOptional: 110V/ 120V/ 220V/ 230V/ 240V/ 415V/ 440V/ 480V) single phase 2 wire
Output VoltageOptional: 220V/ 380V/ 400V/ 415V/ 440V/ 480V) 3 phase 4 wire+PE
Input Current246A at 230V (Input Current=Power/Input Voltage/1.414)
Rated Output Power100 hp (80 kW)
Output WaveformPure sine wave
Output Current115.5A at 400V
Frequnecy50Hz or 60Hz
Power Factor1
Overload Ability150%, 5 Seconds
Efficiency>93%
Waveform Distortion Rated (THD)≤3%(Linear load)
Dynamic Respond (0 to 100% load)5%, ≤50ms
DisplayLCD
Running ModeWorking continously
Electrical Inslation Properties2000Vac, 1 Minute
Communication InterfaceRS485 (Optional)
ProtectionInput under voltage, overvoltage, output over-current, short circuit, overheating etc.
Cooling MethodForced air cooling
Short Circuit ProtectionNo automatic recovery, need to restart the machine
Noise (1 meter)≤50dB
Degree of ProtectionIP20 (indoor)
Working Altitude≤2000m
Woorking Temperature-25~+55°C
Relative Humidty0~90%, Non condensing
Dimension750*750*1480mm
Weight590kg

Single Phase
Single phase
Split phase
Split phase

Details

100 hp Single Phase to 3 Phase Converter Details

Feature

1. Single phase to 3 phase converter input voltage, output voltage, frequency and phase can be customized.
2. Pure sine wave output, transient response is less than 50ms, waveform distortion is minimal, conversion efficiency is high, and output voltage is stable.
3. The static phase converter uses a low frequency transformer to ensure that the input voltage and output voltage are completely electrically isolated to avoid interference.
4. Using SVPWM space vector algorithm, high conversion efficiency, high instantaneous power, low no-load loss, conversion efficiency can reach more than 94%, and no-load loss is small.
5. The output AC power supply is suitable for all types of appliances, power tools, motors, etc. Has a higher driving load capacity.
6. 3 Phase converter has the function of filtering out grid interference and interference at the same time, with stable voltage and frequency power performance, and provides a more stable and pure power supply environment for back-end equipment.
7. Complete output protection function, with output overvoltage, overload, short circuit, overheating, self-diagnostic protection and other protection functions.
8. High conversion efficiency, high instantaneous power and low load loss.
9. Two start modes: step-down start and variable frequency start. Customers can set the startup mode according to the load type. Reduce the use of frequency converters, thereby reducing equipment investment costs, easy wiring and control.

single phase to three phase power converter

Tips: What does three-phase electric phase mean?

Phase, also called perimeter, phase is a dimensionless physical quantity, and its unit is radian. "Phase" is a physical quantity used to reflect the state of motion of a vibrating object.
As we all know that when the coil rotates in a magnetic field, the wire cutting the magnetic field line will generate an induced electromotive force, and its change law can be expressed by a sine curve. If we take three coils and place them 120 degrees apart in space, the three coils are still rotating in the magnetic field at the same speed, and three induced electromotive forces of the same frequency will be induced. Because the three coils are 120 degrees away from each other in space, the generated current is also a three-phase sinusoidal change, which is called three-phase sinusoidal alternating current. Industrial power uses three-phase power, such as three-phase AC motors.
In three-phase four-wire power supply, the voltage between the phase line and the neutral (zero line) is the phase voltage; the voltage between any two phase lines is the line voltage; the line voltage is 3 times the phase voltage. The current flowing through each phase load is the phase current, and the current flowing in the phase line is the line current.
The voltage between any two phases is 380V, and the voltage between any two phases is 220V. It is divided into A phase, B phase, and C phase.

Product reviews
Startup is quick and quiet!
5
Eva
Avatar
4/20/2022 3:14 AM
I was careful with the wiring reading the instructions carefully and this thing worked great for me right off the bat. Saved me a pile and now every 3 phase machine I buy for my home hobby machine shop will have one of these in it. Runs the transformer for the relays and interlocks on my lathe controller flawlessly because i followed the instructions.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews