10~18 Amp Thermal Overload Relay, 220V, 3-Phase

$46.77
Cheap thermal overload relay for sale. 4 ranges of current setting for selection, 10~18 Amp, current rating 25A, working voltage 3-phase 220V~690V, insulation voltage 690V, phase failure protection function, suits 9A contactor and 4~20A gG fuse breaker.
SKU: ATO-TOR-1018
*
This product has a minimum quantity of 2
Free Shipping
Delivery date: 6-12 days

3-phase thermal overload relay for overcurrent and phase-failure protection. It is used to provide overload protection open-phase protection and protection against unbalanced current for motors and it can also avoid heating in electrical equipment. Current setting range 10~18 Amps, rated working current 25A, voltage 220V~690V. Low price thermal relay is matched with 9A contactor, 4~20A gG fuse breaker.

Specification

ModelATO-JR28-25
Current Setting Range (A)5.5-87-109-1312-18
Matching Fuse Breaker (A)gG20202535
aM12121620
Trip Class9A
Frame Current (A)25A
Rated Working Voltage (V)3-phase 220V~690V
Rated Insulation Voltage (V)690V
Number of Contacts1NO + 1NC
Phase Failure Protection Functionyes
Automatic & Manual Resetyes
Temperature Compensationyes
Tripping Indicatoryes
Test Pushbuttonyes
Mounting ModePlug-in, independent
AC-15 220V Current Rating (A)2.73
AC-15 220V Current Rating (A)1.58
DC-13 220V Current Rating (A)0.2

Details

10-18 Amp Thermal Overload Relay Details

Thermal Overload Relay Applications

  • Thermal overload relays are often used in circuit protection, overload, phase failure, overtime start and locked-rotor for AC motors.
  • Thermal overload relay has functions of phase failure protection, temperature compensation, adjustable setting current, automatic or manual reset, operation indicator, NP and NO auxiliary contacts separate insulation.
  • The thermal overload relay has small installation area and various mounting methods. It has test button and stop button, which is convenient for checking the flexibility of operation.
  • The protective cover of thermal overload relay can protect fingers from electric shock. The locking device can prevent misoperation.
  • Thermal overload relay comes with remote operation, complete functions and excellent quality.

10~18 Amp Thermal Overload Relay Dimension Diagram (Unit: mm)

Dimension diagram of 10~18 Amp Thermal Overload Relay, 220V, 3-Phase

Cross Section Area of Conductor

Main CircuitSingle core or standard wire1~4 mm2
Wiring screwM4
Auxiliary CircuitSingle core or standard wire0.5~2.5 mm2
Wiring screwM3.5

Tips: 10A thermal overload relay working principle and functions.

Thermal element of the 10A thermal overload relay is connected to the AC motor circuit directly or through a current transformer. When AC motor is overloaded, the main bimetal is heated to the operating temperature, then relay is activated, and the power circuit of motor is disconnected to prevent the AC motor from being damaged by overload.

The action time of 10A thermal overload relay and the magnitude of overload current change according to the inverse time limit. Therefore, its thermal characteristics are easily matched with the thermal characteristics of AC motors. In addition, 10A thermal overload relay has the features of compact structure, low price, stable action performance, and convenient use. Therefore, since the 1990s, most squirrel-cage rotor motors and some wound-rotor motors still use 3-phase thermal overload relays as protections for overload, phase failure, and current unbalanced operation. 10A thermal overload relay can also be used as a control appliance for the heating state of other electrical equipment.

A thermal relay is an electrical device used for overload protection in electric circuits. Its primary function is to safeguard motors and other electrical equipment from damage due to prolonged overcurrent conditions, such as excessive heat generated by high current flow.

In this video we will try to clear the confusion many people have between relays and contactors by showing you how to tell the difference based on five criteria: Definition, Capacity, Structure, Contacts and Applications.

Product reviews
Good Current Range and Voltage Compatibility:
5
Vesper
Avatar
10/24/2023 2:22 AM
It covers a decent range of current, which worked well for my 3-phase setup. The 220V support fits my requirements and many standard power systems. These are very good
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

3-phase thermal overload relay for overcurrent and phase-failure protection. It is used to provide overload protection open-phase protection and protection against unbalanced current for motors and it can also avoid heating in electrical equipment. Current setting range 10~18 Amps, rated working current 25A, voltage 220V~690V. Low price thermal relay is matched with 9A contactor, 4~20A gG fuse breaker.

Specification

ModelATO-JR28-25
Current Setting Range (A)5.5-87-109-1312-18
Matching Fuse Breaker (A)gG20202535
aM12121620
Trip Class9A
Frame Current (A)25A
Rated Working Voltage (V)3-phase 220V~690V
Rated Insulation Voltage (V)690V
Number of Contacts1NO + 1NC
Phase Failure Protection Functionyes
Automatic & Manual Resetyes
Temperature Compensationyes
Tripping Indicatoryes
Test Pushbuttonyes
Mounting ModePlug-in, independent
AC-15 220V Current Rating (A)2.73
AC-15 220V Current Rating (A)1.58
DC-13 220V Current Rating (A)0.2

Details

10-18 Amp Thermal Overload Relay Details

Thermal Overload Relay Applications

  • Thermal overload relays are often used in circuit protection, overload, phase failure, overtime start and locked-rotor for AC motors.
  • Thermal overload relay has functions of phase failure protection, temperature compensation, adjustable setting current, automatic or manual reset, operation indicator, NP and NO auxiliary contacts separate insulation.
  • The thermal overload relay has small installation area and various mounting methods. It has test button and stop button, which is convenient for checking the flexibility of operation.
  • The protective cover of thermal overload relay can protect fingers from electric shock. The locking device can prevent misoperation.
  • Thermal overload relay comes with remote operation, complete functions and excellent quality.

10~18 Amp Thermal Overload Relay Dimension Diagram (Unit: mm)

Dimension diagram of 10~18 Amp Thermal Overload Relay, 220V, 3-Phase

Cross Section Area of Conductor

Main CircuitSingle core or standard wire1~4 mm2
Wiring screwM4
Auxiliary CircuitSingle core or standard wire0.5~2.5 mm2
Wiring screwM3.5

Tips: 10A thermal overload relay working principle and functions.

Thermal element of the 10A thermal overload relay is connected to the AC motor circuit directly or through a current transformer. When AC motor is overloaded, the main bimetal is heated to the operating temperature, then relay is activated, and the power circuit of motor is disconnected to prevent the AC motor from being damaged by overload.

The action time of 10A thermal overload relay and the magnitude of overload current change according to the inverse time limit. Therefore, its thermal characteristics are easily matched with the thermal characteristics of AC motors. In addition, 10A thermal overload relay has the features of compact structure, low price, stable action performance, and convenient use. Therefore, since the 1990s, most squirrel-cage rotor motors and some wound-rotor motors still use 3-phase thermal overload relays as protections for overload, phase failure, and current unbalanced operation. 10A thermal overload relay can also be used as a control appliance for the heating state of other electrical equipment.

Product reviews
Good Current Range and Voltage Compatibility:
5
Vesper
Avatar
10/24/2023 2:22 AM
It covers a decent range of current, which worked well for my 3-phase setup. The 220V support fits my requirements and many standard power systems. These are very good
Was this review helpful? Yes No (0/0)
Only registered users can write reviews