0.5 HP (0.37 kW) Automatic Water Pressure Booster Pump

$297.94
Small automatic water booster pump for house, 0.5 HP (0.37 kW), single phase or 3 phase, optional voltage 220V, rated current 370A, 1 in. water inlet and outlet, max. head 40m, max. flow 30 LPM, comes with motor to increase water pressure.
SKU: ATO-BP-05HP
Free Shipping
Delivery date: 6-12 days

1/2 HP (0.37 kW) water booster pump with motor is used to increase the pressure of water. It accepts cold and hot water, which is suitable for home use, sprinkler and irrigation system, small air conditioner system, and washing machine, etc.

Specification

ModelATO-PQT-370A
Power0.5 HP (0.37 kW)
Voltage (AC)220V
PhaseSingle Phase / 3 Phase
Max. Flow30 L/min
Max. Head40m
Rated Flow32m³/h
Rated Head35m
Max. Suction9m
Inlet Diameter1 inch
Outlet Diameter1 inch
PumpMax. Liquid Temperature35℃ or 60℃
Max. Suction+8m
MaterialBrass Impeller with Evenly Arranged Radial Vanes
MotorMax. Ambient Temperature+40℃
Insulation ClassB or F
ProtectionIP x 4
CoolingExternal Ventilation
ShaftStainless Steel Welded Shaft/45# Steel Shaft
Packing Dimension290mm * 250mm * 310mm
Weight15kg

Applications

1.5 HP (1.1 kW) Single Phase Automatic Water Booster Pump Applications

Details

Automatic Water Pressure Booster Pump Details

Tips: Automatic water booster pump troubleshooting

FaultsReasonsSolutions
The booster pump runs but no water output.
  • The water in the pump is not full.
  • Wrong direction of rotation.
  • The impeller passage is blocked.
  • Inject water into the pump again.
  • Drain the impeller passage.
  • Adjust the direction of rotation.
The booster pump flow is insufficient.
  • The pump is blockage.
  • Low revolution.
  • The impeller is damage.
  • The outlet valve opening is too large.
  • Clean the pump and tube.
  • Replace the impeller.
  • Add shaft revolution.
  • Turn down the outlet valve.
The pressure of the outlet is insufficient.
  • There is air in the liquid.
  • Low revolution.
  • The impeller is damage.
  • The outlet valve opening is too large.
  • Expel air from the liquid.
  • Replace the impeller.
  • Add shaft revolution.
  • Turn down the outlet valve.
The booster pump consumes too much power (motor heating).
  • Mechanical defects: Running clearance is too small; the motor shaft is bent; bolts looseness.
  • The booster pump operates well below the rated head.
  • Check the mechanical parts and solve the problems in time.
  • Adjust the outlet valve to make sure the pump works near the rated flow and rated head.
The booster water pump vibration.
  • The piping system is not well supported.
  • The impeller is blocked causing imbalance and cavitation effect.
  • There is air in the liquid.
  • Check the support part of the pump.
  • Tighten the bolts.
  • Drain the impeller passage to make it balance.
  • Expel air from the liquid.
The booster pump is water leakage.
  • The mechanical sealing is damage.
  • The O-ring is damage.
  • The pump itself is water leakage.
  • Replace the mechanical sealing and O-ring.
  • Welding the pump body where it leaks.
Excessive pump noise.
  • The bearing is overheating and lack of oil.
  • The booster pump is overload.
  • Fill oil in the bearing.
  • Check the mechanical parts and solve the problems in time.

Proposition 65 Warning

*WARNING: This product can expose you to chemicals, including lead, which is known to the State of California to cause birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.

Product reviews
Great automatic water booster pump
5
Amazon
Avatar
7/12/2021 2:53 AM
I am pleased with this 0.5 HP automatic water booster pump. It works as described and has not failed since installation. This pump is quieter than most pumps. It is perfect and easy to install for a garden system with rainwater collection.
Was this review helpful? Yes No (0/0)
Great water booster pump.
5
Daniel
Avatar
3/14/2022 2:30 AM
I bought this 0.5 HP automatic water booster pump for home use. Love the small size and ability to install in any direction. This pump is self-priming and have good pressure. Great water pump for the money. Highly recommend.
Was this review helpful? Yes No (0/0)
Very easy to install.
5
Michael
Avatar
5/19/2022 7:06 PM
I got this automatic booster pump yesterday, it was very easy to install and very quiet. I used it to boost water pressure in my home water system, it worked great. I would buy again. I am very satisfied with this pump and I highly recommend it.
Was this review helpful? Yes No (0/0)
Can we adjust the speed of motor of water pump?
5
kamran
Avatar
6/12/2023 9:18 PM
Sorry I don’t understand that variable speed means variable flow. And what is the purpose of variable?
Can we adjust speed of the motor and is it a 3 phase motor?
Is there a drive or can we operate it with a drive?
Can I call you and which phone number?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, variable speed means variable flow. But the adjustment speed of single-phase water pump is very limited. If you want to adjust the speed and flow of the pump, we recommend that you use a three-phase 220V, 60Hz pump, and then cooperate with our single-phase 220V input and three-phase 220V output VFD.
Could you please tell us what the head and flow requirements of your pump are? What is the specific flow range required for regulation?
Please refer to: https://www.ato.com/1-hp-variable-speed-pool-pump
https://www.ato.com/3hp-vfd
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

1/2 HP (0.37 kW) water booster pump with motor is used to increase the pressure of water. It accepts cold and hot water, which is suitable for home use, sprinkler and irrigation system, small air conditioner system, and washing machine, etc.

Specification

ModelATO-PQT-370A
Power0.5 HP (0.37 kW)
Voltage (AC)220V
PhaseSingle Phase / 3 Phase
Max. Flow30 L/min
Max. Head40m
Rated Flow32m³/h
Rated Head35m
Max. Suction9m
Inlet Diameter1 inch
Outlet Diameter1 inch
PumpMax. Liquid Temperature35℃ or 60℃
Max. Suction+8m
MaterialBrass Impeller with Evenly Arranged Radial Vanes
MotorMax. Ambient Temperature+40℃
Insulation ClassB or F
ProtectionIP x 4
CoolingExternal Ventilation
ShaftStainless Steel Welded Shaft/45# Steel Shaft
Packing Dimension290mm * 250mm * 310mm
Weight15kg

Applications

1.5 HP (1.1 kW) Single Phase Automatic Water Booster Pump Applications

Details

Automatic Water Pressure Booster Pump Details

Tips: Automatic water booster pump troubleshooting

FaultsReasonsSolutions
The booster pump runs but no water output.
  • The water in the pump is not full.
  • Wrong direction of rotation.
  • The impeller passage is blocked.
  • Inject water into the pump again.
  • Drain the impeller passage.
  • Adjust the direction of rotation.
The booster pump flow is insufficient.
  • The pump is blockage.
  • Low revolution.
  • The impeller is damage.
  • The outlet valve opening is too large.
  • Clean the pump and tube.
  • Replace the impeller.
  • Add shaft revolution.
  • Turn down the outlet valve.
The pressure of the outlet is insufficient.
  • There is air in the liquid.
  • Low revolution.
  • The impeller is damage.
  • The outlet valve opening is too large.
  • Expel air from the liquid.
  • Replace the impeller.
  • Add shaft revolution.
  • Turn down the outlet valve.
The booster pump consumes too much power (motor heating).
  • Mechanical defects: Running clearance is too small; the motor shaft is bent; bolts looseness.
  • The booster pump operates well below the rated head.
  • Check the mechanical parts and solve the problems in time.
  • Adjust the outlet valve to make sure the pump works near the rated flow and rated head.
The booster water pump vibration.
  • The piping system is not well supported.
  • The impeller is blocked causing imbalance and cavitation effect.
  • There is air in the liquid.
  • Check the support part of the pump.
  • Tighten the bolts.
  • Drain the impeller passage to make it balance.
  • Expel air from the liquid.
The booster pump is water leakage.
  • The mechanical sealing is damage.
  • The O-ring is damage.
  • The pump itself is water leakage.
  • Replace the mechanical sealing and O-ring.
  • Welding the pump body where it leaks.
Excessive pump noise.
  • The bearing is overheating and lack of oil.
  • The booster pump is overload.
  • Fill oil in the bearing.
  • Check the mechanical parts and solve the problems in time.

Product reviews
Great automatic water booster pump
5
Amazon
Avatar
7/12/2021 2:53 AM
I am pleased with this 0.5 HP automatic water booster pump. It works as described and has not failed since installation. This pump is quieter than most pumps. It is perfect and easy to install for a garden system with rainwater collection.
Was this review helpful? Yes No (0/0)
Great water booster pump.
5
Daniel
Avatar
3/14/2022 2:30 AM
I bought this 0.5 HP automatic water booster pump for home use. Love the small size and ability to install in any direction. This pump is self-priming and have good pressure. Great water pump for the money. Highly recommend.
Was this review helpful? Yes No (0/0)
Very easy to install.
5
Michael
Avatar
5/19/2022 7:06 PM
I got this automatic booster pump yesterday, it was very easy to install and very quiet. I used it to boost water pressure in my home water system, it worked great. I would buy again. I am very satisfied with this pump and I highly recommend it.
Was this review helpful? Yes No (0/0)
Can we adjust the speed of motor of water pump?
5
kamran
Avatar
6/12/2023 9:18 PM
Sorry I don’t understand that variable speed means variable flow. And what is the purpose of variable?
Can we adjust speed of the motor and is it a 3 phase motor?
Is there a drive or can we operate it with a drive?
Can I call you and which phone number?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, variable speed means variable flow. But the adjustment speed of single-phase water pump is very limited. If you want to adjust the speed and flow of the pump, we recommend that you use a three-phase 220V, 60Hz pump, and then cooperate with our single-phase 220V input and three-phase 220V output VFD.
Could you please tell us what the head and flow requirements of your pump are? What is the specific flow range required for regulation?
Please refer to: https://www.ato.com/1-hp-variable-speed-pool-pump
https://www.ato.com/3hp-vfd
Only registered users can write reviews
Customers who bought this item also bought

G1/2" Magnetic Water Flow Switch

ATO-MR-2260
$57.79
Water flow switch is a flow sensor which consists of magnetic core, external case and reed switch, G1/2 thread, 50W, optional flow rate 15, 30, 50 L/min, reliable components of the reed switch with low price.

1/2" Digital Flow Switch for Water

ATO-FLOW-W12
$307.99
Factory price digital water flow switch for sale, 1/2 inch thread port size, with digital display for real time monitoring, ±2% accuracy, measuring water and ethylene glycol aqueous solution, fluid temperature 0~90℃. This water flow switch comes with water sensor, which is designed for flow sensing to transmit data to the mainboard.